the software. ‧If the treatments above do not work, there is a possibility t h at MPX board(s) in the machine is broken. You need to repl ace it(them) with new ones. E610045 “ ATC(L) sli de plate can not be shut down ” “…

100%1 / 464
‧Something is wrong with the movement of the ATC slide plate. In this case, the following cases
can be possible.
A) The speed controller of the slide plate driving cylinder is wrung to its minimum limit. Please
loosen the speed controller of the slide plate driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong. There is a possibility that the
sensor gets ON before the slide plate fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being opened/closed. Please examine if
there is anything caught in near the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct. Please examine if the air pipe is
properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the connector part of the slide
plate plays too much. Please examine if the nut is tightened up enough.
‧The ATC coordinates or the nozzle change height is not correct. If you change the coordinates or
the height, please select [Setup(S)] [MS parameter] and follow the Maintenance manual. For MS
parameter, it is limited that who can change the parameter by the user level setting.
E610043 Head traveling coordinates are within the head interference range(SLOW)
Head 移动坐标位于另一个 Head 干扰范围内(SLOW),所以不能移动。
[Cause]
The left and right heads can not move at high speed since they interfere each other when they travel
to the specified ATC position simultaneously. Some program versions in the machine may be
clashing with each other.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610044 Head traveling coordinates are within the head interference range(STOP)
Head 移动坐标位于另一个 Head 干扰范围内(STOP),所以不能移动。
[Cause]
The left and right heads can not move at high speed since they interfere each other when they travel
to the specified ATC position simultaneously. Some program versions in the machine may be
clashing with each other.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610045 ATC(L) slide plate can not be shut down
不能关闭 ATC()滑板。
[Cause]
ATC slide plate has to be closed when trying to change nozzles but it was open. The process of
closing the slide plate yet the plate did not get closed. This error is likely to happen when the lock
valve of the solenoid valve, which drives the slide plate remains closed. The following causes are also
possible.
‧The air is not being supplied properly.
‧The slide plate that slides left and right to open and close the plate in the ATC unit does not work
properly.
‧The sensor which detects the position of the slide plate is not tuned well or broken.
[Treatment]
Please select [Manual Control] from the menu bar, and then select [Control(C )] [Other(O)] [ATC
Control(A)]. Set 'Control Unit' to 'light ATC', and select 'Slide plate Control(A)' from the 'Control
Item' frame' to open/close the slide plate. Please perform one of the treatments below according to the
result you get.
1. Slide plate works properly.
1.1 The 'Slide plate OFF sensor' in the 'Status' displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too much toward its minimum
limit. Please loosen the controller.
1.2 The 'Slide plate OFF sensor' in the 'Status' displaying frame does not get ON/OFF.
‧There is a possibility that the Slide plate OFF sensor was adjusted to out of the Cylinder's movable
range. Please re-adjust the sensor to where it gets ON/OFF.
‧If the treatment1 does not work, there is a possibility that the slide plate OFF sensor is broken. It
could be that the wiring came off the connector part, that a contact pin in the connector part is broken,
that the wiring got cut off, or that the sensor itself is broken. Please examine the wiring and connector.
If any of them are broken, you need to replace them with new ones.
‧If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
2. Slide plate does not work.
‧There is a possibility that the lock valve of the solenoid valve, that drives the slide plate, is closed.
Please make sure that the lock valve of the solenoid valve is opened all the way.
‧There is a possibility that a nozzle is not installed in the ATC correctly and that prevent the slide
plate from sliding properly. Please see if nozzles are correctly installed in the ATC.
‧There is a possibility that a component or implement got caught in the sliding part of the slide plate
and that prevents the slide plate from sliding properly. Please see if there is anything on the slide
plate.
‧There is a possibility that the air supplying pipes to the slide plate driving cylinder have a problem.
It could be that the speed controller is fully tightened up, that the air pipe came off the cylinder, or a
wrong air pipe is connected to the cylinder. Please see the air pipes and make sure that correct pipes
are connected.
‧There is a possibility that the connecting part between the shaft of the slide plate driving cylinder
and the slide plate has a problem. It could be that the nut attached to the tip of the shaft fell off, that
the shaft got chipped or broken, or that the plate got chipped or broken. You need to have the
damaged part repaired or replace it with a new one.
‧There is a possibility that the slide plate driving cylinder is broken. Please stop the air supplying on
the machine and see if the slide plate works fine manually. If the plate does not work smoothly, you
need to replace it with a new one.
‧There is a possibility that the slide plate driving solenoid valve is broken. It could be that the
wiring came off the connector part, that a contact pin in the connector part is broken, that the wiring
got cut off, or the solenoid valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
‧If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E610046 ATC(R) slide plate can not be shut down
不能关闭 ATC()滑板。
[Cause]
ATC slide plate has to be closed when trying to change nozzles but it was open. The process of
closing the slide plate yet the plate did not get closed. This error is likely to happen when the lock
valve of the solenoid valve, which drives the slide plate remains closed. The following causes are also
possible.
‧The air is not being supplied properly.
‧The slide plate that slides left and right to open and close the plate in the ATC unit does not work
properly.
‧The sensor which detects the position of the slide plate is not tuned well or broken.
[Treatment]
Please select [Manual Control] from the menu bar, and then select [Control(C )] [Other(O)] [ATC
Control(A)]. Set 'Control Unit' to 'right ATC', and select 'Slide plate Control(A)' from the 'Control
Item' frame' to open/close the slide plate. Please perform one of the treatments below according to the
result you get.
1. Slide plate works properly.
1.1 The 'Slide plate OFF sensor' in the 'Status' displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too much toward its minimum
limit. Please loosen the controller.