JUKI贴片机错误代码.pdf - 第9页
Please press 'Yes' to end the system. If you do not want to fin ish the system, please press 'No'. E105010 “ Fatal error occurred in constructing memory structure. | Abort the process ” “ 内存构造发生错误。 | …
40000 : 创建信箱失败
80000: Failure in creating IPC for command response.
80000 : 建立命令应答用 IPC 失败
100001: Failure in starting the main process of the Error Manager
100001 : 启动错误管理主进程失败
100002: Failure in starting the error process thread1.
100002 :启动错误处理线程 1 失败
100003: Failure in starting the error process thread2.
100003 :启动错误处理线程 2 失败
100004: Failure in starting the error process thread3.
100004 :启动错误处理线程 3 失败
100005: Failure in starting the error process thread4.
100005 :启动错误处理线程 4 失败
800000: Failure in starting the non-synchronized process.
800000 :启动异步处理失败
1000001: Failure in starting the external communication process.
1000001 :启动外部通讯处理失败
1000002: Failure in hand-shaking with the external communication process.
1000002 :与外部通讯处理的手动连接失败
4000001: NT error OLE server
4000001 :NT 错误(OLE server)
4000002: NT error (Specifying a dispatch command)
4000002 :NT 错误(发送命令的指定)
4000003: Failure in learning the Vision version.
4000003 :取得图像版本失败
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
退出所有程序,并关闭计算器后,重新启动主机。
If the error occurs even after the rebooting, please take a note of the error number and contact our
technical service dept. for information.
如果重新启动也发生同样错误,系统文件可能已破坏。
请记好错误代码,并与代理店或本公司技朮服务部联系。
W102900 “System is closing all processes. | And getting into the shut-down process. | Are you sure?”
“退出所有程序,并关闭计算器。|是否继续?”
[Cause]
All the programs currently running are aborted and WindowsNT starts the shut-down session.
[Treatment]
Please press 'Yes' to end the system. If you do not want to finish the system, please press 'No'.
E105010 “Fatal error occurred in constructing memory structure. | Abort the process”
“内存构造发生错误。|请关闭程序,重新启动。”
[Cause]
A critical error occurred while saving or initializing the system memory.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is a possibility that a system file is broken.
Please take a note of the error number and contact our technical service dept. for information.
W105110 “The saving program has no name. | Please put the name?”
“要保存的生产程序没有文件名。|请输入文件名保存。”
[Cause]
The program to save does not have a name yet. It has a temporary name (UNTITLED) now.
[Treatment]
Please name the file before saving it.
W105120 “The same named file exists. | Do you want to overwrite the file?”
“已经存在同样文件名。 |是否覆盖保存?”
[Cause]
There is a file which has the same name as your file in the directory that you are trying to save your
file in.
[Treatment]
When you do not need to rename your file, press 'OK'. If you need to save your file with a different
name, press 'Cancel' and rename the file.
W105130 “There is no saving data.”
“没有保存数据。”
E106010 “Failed to start the data-manager. | Abort the process”
“启动数据管理失败。|请关闭程序,重新启动。”
[Cause]
Failed to start the Data Manager.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is a possibility that Machine Information Database,
Machine Control Data file, Flash Memory for saving Control Data, or NT registry setting has a
problem.
Please take a note of the error number and contact our technical service dept. for information.
W106020 “Illegal password. | Retrieve the default group settings”
“密码错误。|返回缺省用户组。”
[Cause]
When changing the user level, the password was wrong.
[Treatment]
Please enter the right password in the User level setting again.
If you do not remember your password, please take a note of the error number and contact our
technical service dept. for information.
W106030 “Can not change to the specified group.|(The system error has occurred.)”
“因系统发生错误,现在的用户级别是不能进行修改。”
E107001 “This Function is not available now, sorry.”
“不能使用当前功能。”
E107100 “Failed to create asynchronous threads. | Abort the process”
“启动异步处理失败。|请关闭程序,重新启动。”
[Cause]
Failed to start the non-synchronized process.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is a possibility that a system file is broken.
Please take a note of the error number and contact our technical service dept. for information.
Q107500 “There are emergency backup files. |Do you want to restore the data to the memories ?”
“存在紧急备份文件。|是否复原数据?”
E107501 “The Emergency backup files are broken. |Clear these files.”
“紧急备份文件被破坏。|是否删除?”
Q107502 “The backup data is resumed. |Do you want to remove these backup files.”
“已经复原数据。|是否删除备份文件?”
Q107503 “Do you want to remove these backup files. |If you remove these files, you can not resume the data.”
“是否删除备份文件?|如果删除,就不能复原文件。”
E108010 “Failed to start up MC system. | Abort the process”
“启动 MC 失败。|请关闭程序,重新启动。”