Please turn off the power supply of your machine. If the error occurs even after the reboot, please see if the cables are connected prope rly. If the error still occurs even when the cables are connected properly, you ne…
“发生 RZ2 驱动警报。”
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head2.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head2 with a new one.
E610234 “RZ3 Driver alarm occurred”
“发生 RZ3 驱动警报。”
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head3 with a new one.
E610235 “RZ4 Driver alarm occurred”
“发生 RZ4 驱动警报。”
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head4 with a new one.
E610236 “LT1 Driver alarm occurred”
“发生 LT1 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head1.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head1 with a new one.
E610237 “LT2 Driver alarm occurred”
“发生 LT2 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head2.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head2 with a new one.
E610238 “LT3 Driver alarm occurred”
“发生 LT3 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head3 with a new one.
E610239 “LT4 Driver alarm occurred”
“发生 LT4 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head4 with a new one.
E610240 “RT1 Driver alarm occurred”
“发生 RT1 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head1.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head1 with a new one.
E610241 “RT2 Driver alarm occurred”
“发生 RT2 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head2.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head2 with a new one.
E610242 “RT3 Driver alarm occurred”
“发生 RT3 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head3 with a new one.
E610243 “RT4 Driver alarm occurred”
“发生 RT4 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head4 with a new one.
E610244 “XH Driver alarm occurred.”
“发生 XH 驱动警报。”
E610245 “The power supply OFF of a VME bus occurred.”
“发生 VME 的断电。”
E610246 “Power OFF occurred.”
“发生停电。”
E610247 “XY limit occurred.”
“发生 XY 超界。”
E610248 “ZT limit occurred.”
“发生 Zθ超界。”
E610249 “XY Driver alarm occurred.”
“发生 XY 驱动警报。”
E610300 “An error occurred when ComRes command send”
“发送 COMRES 命令出错。”
[Cause]
Command sending of Command-response type failed. This is an error that occurred during the data
communication in the machine.
[Treatment]