JUKI贴片机错误代码.pdf - 第462页
E6907 Adhesi ve data not complete yet. " 贴装数据不完全 ." [Cause] There is incomplete adhesion data. [Deal] Correct the data (adhesion) specification. E8001 “ No protect module! “ " 无保护模式 !" E8002 “ Product…
"电路数量超出范围."
[Cause]
The maximum number of circuits available for this line was exceeded.
[Deal]
Decrease the data (number of PWB data circuits) to the limit or less.
E6902 Needle number Error.
"针数量错误."
[Cause]
The needle type for the specified station is different from that for the adhesion data.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6903 Head number undefined Error.
"贴装头数量未定义."
[Cause]
A failure was found in the data.
[Deal]
Correct the data (adhesion data needle) specification.
E6904 Head number Error.
"贴装头的数量错误."
[Cause]
The head to use is disabled.
[Deal]
Start the MST setup to enable the needle.
E6905 Placement position is out of range.
"贴片位置超过范围."
[Cause]
Excessive mounting data were specified.
[Deal]
Decrease the mounting data to the limit or less.
E6906 Internal Error.
"内部错误."
[Cause]
EPU770 (Hlc Div Dispensor Optimize) error return values, -2, -3, -4
[Deal]
Consult the manufacturer.
E6907 Adhesive data not complete yet.
"贴装数据不完全."
[Cause]
There is incomplete adhesion data.
[Deal]
Correct the data (adhesion) specification.
E8001 “No protect module! “
"无保护模式!"
E8002 “Product planning cannot run with MSL Setup simultaneously. “
"生产计划不能和 MSL 设置同时运行。"
E8003 “Product reservation file cannot be opened, as the reserved file or files could not be found. “
"产品保留文件不能打开, 找不到保留文件。"
W8004 “If you change the product reservation, you have to close all the window and re-optimize because
the previous optimization file will not match. “
"如果要改变产品保留,你必须关闭所有窗口和重新优化因为以前的优化文件不匹配。"
E8005 "Write protected! “
"写保护!"
E8006 “Illegal data input! “
"输入的非法数据!"
E8007 “No displayable data. window cannot be opened. “
"没有可显示数据,窗口不能打开。"
E8008 “Optimization cannot be excuted, bacause the line configuration mismatches between program file
and MSL-setup. You need to change your program file. “
"优化不能执行,因为在程序文件和 MSL-设置之间的线结构不匹配。"