[Cause]
This error occurs when trying to teach a feeder pickup coordinate on the right feeder bank to the
machine by using a device on the left side.
[Treatment]
Please use a device on the right side when teaching a feeder pickup coordinate on the right feeder
bank to the machine.
E290005 The pick up point in the left feeder bank cannot be the teaching with a right device. Please use a left
device
不能以右侧装置示教左侧送料器台架上的吸着坐标。请选用左侧装置。
[Cause]
This error occurs when trying to teach a feeder pickup coordinate on the left feeder bank to the
machine by using a device on the right side.
[Treatment]
Please use a device on the left side when teaching a feeder pickup coordinate on the left feeder bank
to the machine.
E290006 The memory access error occurred
访问内存出错。
[Cause]
Failed to write the data in or to read the data from the shared memory.
[Treatment]
Please reboot the machine. If the error occurs even after rebooting, please contact our technical
service dept. for information.
E290007 The Head device is set in unused by the setup
在设置中,Head 置没有被选用。
[Cause]
The specified head is set to not use in the Use unit in Setup.
[Treatment]
If the specified head is available, please set it to use in the Use unit in Setup. If not, this procedure
cannot be executed.
E290008 HW error. Execution is aborted
因硬件出错,停止运行。
[Cause]
A requested action to an axis or other hardware got an error. There may be a possibility of alarm
occurrence, servo free, Emergency STOP, etc.
[Treatment]
Please try Servo Free unlocking, Home returning, etc.
E290009 Can not mark-teaching by R OCC. L OCC use,please.”
右侧 OCC 不能示教标记,请使用左侧 OCC
E290010 DTS cannot be executed.”
不能运 DTS
E290011 DTS is not initialized.”
DTS 没有初始化。
E290012 DTS safety cover opens.”
DTS 安全盖被打开。
E290013 DTS is in the state of supply.”
DTS 处于补充状态。
E290014 DTS failed in drawing out the tray.”
DTS 取出托盘失败。
E290015 DTS device is set in unused by the setup.”
在设置中,DTS 装置没有被选用。
E290016 It is not possible to move to specified position with this device.”
这个设备不能移到指定坐标上。
E290017 Check sum error of template data. Please teaching try again.”
检查模板数据合计出错。请再次示教修改。
E290020 There is no power supply of MTS.”
没有打 MTS 电源。
E290021 MTS is stopping the emergency.”
MTS 被紧急停止。
E290022 MTS is not initialized.”
没有初始化 MTS
E290023 MTS is in the state of off-line.”
没有连 MTS
E290024 MTS stacker cover opens.”
MTS 托盘存储箱盖被打开。
E290025 MTS is in the state of supply.”
MTS 处于补充状态。
E290026 There is no MTS stacker.”
MTS 托盘存储箱不存在。
E290027 MTS failed in drawing out the tray.”
MTS 取出托盘失败。
E290028 MTS device is set in unused by the setup.”
在设置中,MTS 装置没有被选用。
E290029 Transmit error of template data. Please teaching try again.”
模板数据传输发生错误。请再次示教修改。
E290030 The bank mark recognition error (MTS). | Teaching is aborted.”
识别台架标记出错(MTS)| 停止运行
Q290500 It is not possible to move to specified position with this device. | Please push 'No' when you
discontinue 'Yes' when the teaching is started from the current position
这个设备不能移到指定坐标上。|从当前位置开始示教,请按[]﹔停止,请按[]
[Cause]
You can not move to the previously set coordinates with the device selected by HOD. You are asked
if to resume the teaching from the current position.
[Treatment]
If you want to continue the process, press Yes. If not, press No.
Q290501 The teaching operation is executed. Please confirm safety. | Please push 'No' when you discontinue
'Yes' when executing this
运行示教操作,请注意安全。|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check since this operation takes axis traveling.
[Treatment]
If you want to continue the process, press 'Yes'. If not, press 'No'.
Q290502 The position cannot be corrected. | Please push 'No' when you discontinue 'Yes' when correction is
not considered and teaching is executed
不能运行坐标校正。|不考虑校正继续运行示教,请按[]﹔停止,请按[]
[Cause]
You need to correct the coordinates in order to teach the coordinates to the machine accurately, but
the Mark recognition that is necessary for the coordinate correction failed for some reason. You are
asked if to continue the teaching although the accurate teaching cannot be expected if you continue
the process..
[Treatment]
If you want to continue the process, press 'Yes'. If not, press 'No'.