JUKI贴片机错误代码.pdf - 第220页

“ 发生 +Y 界限 。 ” [Cause] The head is on the +limit sensor (rear sid e) which is on the Y axis. [Treatment] Please get the head o ff the limit sensor, a nd then perform the Home returning. E610210 “ Y limit occurred ” “ 发生 …

100%1 / 464
If the error occurs when there is nothing to interrupt the sensor, the light axis of the Feeder floatation
sensor may not be aligned well. Please examine if the light emitted from the sensor is received by its
light receiver properly. If the light is received properly, the red and green LEDs on the sensor get on.
This error also occurs when the Feeder floatation sensor itself or MCM board in the sensor is broken.
There is a great possibility that the sensor itself or the MCM board in the sensor is broken when this
error keeps happening even if you adjust the alignment of the light axis. If you want to avoid the error
temporarily to continue the production, please select [Machine Setup] from the menu bar, and then
[Setting Group(G)] [Use Unit(D)]. Please the tab of [Use Unit1] and disable the checkbox of the
Feeder floatation sensor.
Caution! If you do not use the Feeder floatation sensor for your production, make sure that nothing
interrupts the sensor. If a head should clash with an obstruction, that may cause a serious accident.
E610205 +X limit occurred
发生+X 界限
[Cause]
The head is on the +limit sensor which is on the right side of X axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610206 -X limit occurred
发生-X 界限。
[Cause]
The head is on the -limit sensor which is on the left side of X axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610207 XR limit occurred
发生+XR 界限。
[Cause]
The right head is on the +limit sensor which is on the right side of X axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610208 XR limit occurred
发生-XR 界限。
[Cause]
The right head is on the -limit sensor which is around the center of X axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610209 Y limit occurred
发生+Y 界限
[Cause]
The head is on the +limit sensor (rear side) which is on the Y axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610210 Y limit occurred
发生-Y 界限。
[Cause]
The head is on the -limit sensor (front side) which is on the Y axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610211 YCNV limit occurred
发生+YCNV 界限。
[Cause]
The movable station (right side) of the PWB conveyor is on the +limit sensor (rear side).
[Treatment]
1. If the right movable station is inward of the machine by 5mm compared with the left fixed station.
If your machine installs a changer table on it, please take it off your machine. Stick your hand from
the front side of the machine and reach beneath the backup table. Turn the coupling part that holds a
ball screw and a motor axis that drive the movable station in order to adjust the position of the
movable station to the position of the left station.
2. If the position of the right movable station is almost on the same position as the left station.
The limit sensor of the movable station is broken. It could be that the sensor itself is broken or that a
connector came off the sensor. Please take the backup table off the machine and examine the sensor.
E610212 YCNV limit occurred
发生-YCNV 界限。
[Cause]
The movable station (right side) of the PWB conveyor is on the -limit sensor (front side).
[Treatment]
1. If the right movable station is outward of the machine by 5mm compared with the left fixed station.
If your machine installs a changer table on it, please take it off your machine. Stick your hand from
the front side of the machine and reach beneath the backup table. Turn the coupling part that holds a
ball screw and a motor axis that drive the movable station in order to adjust the position of the
movable station to the position of the left station.
2. If the position of the right movable station is almost on the same position as the left station.
The limit sensor of the movable station is broken. It could be that the sensor itself is broken or that a
connector came off the sensor. Please take the backup table off the machine and examine the sensor.
E610213 The error not forecast occurred
发生未知错误。
[Cause]
An undefined error occurred.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610214 X Driver alarm occurred
发生 X 驱动警报。
[Cause]
An abnormal matter happened to the servo driver of the X axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of X axis with a new one.
E610215 XR Driver alarm occurred
发生 XR 驱动警报。
[Cause]
An abnormal matter happened to the servo driver of the XR axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of XR axis with a new one.
E610216 Y Driver alarm occurred
发生 Y 驱动警报。
[Cause]
An abnormal matter happened to the servo driver of the Y axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of Y axis with a new one.
E610217 XR Driver alarm occurred
发生 YR 驱动警报。
[Cause]
An abnormal matter happened to the servo driver of the YR axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the