" 头不能移动到选取点 ." [Cause] The pick-up position is not set w ithin the area where a head ca n move. [Deal] Ch ange the pick-up p osition to a new positio n where a head can move. E3825 St ation which can handle sel…

100%1 / 464
E3819 Station which can handle No.5 nozzle is not in the line.
"能处理 5 号吸嘴的位置不在线上."
[Cause]
Indicates that there is no 720 station on the preset line during the MSL setup.
[Deal]
Add a 720 station or do not use nozzle 5.
Set a station capable of using trays on the line.
E3820 The number of selected nozzle is set as 0 in resource table.
"选择吸嘴的数量在资源表中设置 0."
[Cause]
Indicates that the number of nozzles is set to 0 on the resource table during the MSL setup.
[Deal]
Specify an appropriate value for the resource table of the specified nozzle during the MSL setup.
E3821 Station which can handle component more than 6mm is not in the line.
"能处理 6mm 以上组件的位置不在线上."
[Cause]
Indicates that there is none of 720, 730, 740,750,760,2010,2020 or 2040.
[Deal]
Add any of a 720, 730, 740,750, 760,2010,2020 or 2040 station during the MSL setup.
E3822 The number of selected tape feeder is set as 0 in resource table.
"选择带状送料器的数量在资源表中设置为 0."
[Cause]
Indicates that the number of the tape feeders of the specified tape width is set to 0 on the resource
table during the MSL setup.
[Deal]
Specify an appropriate value for the number of the tape feeders of the specified tape width on the
resource table during the MSL setup.
E3823 The number of selected stick feeder is set as 0 in resource table.
"选择管状供料器的数量在资源表中设置为 0."
[Cause]
Indicates that the number of the specified stick feeder types is set to 0 in the resource table during the
MSL setup.
[Deal]
Specify an appropriate value for the number of the specified stick feeder types in the resource table
during the MSL setup.
E3824 A head cannot move to pick point.
"头不能移动到选取点."
[Cause]
The pick-up position is not set within the area where a head can move.
[Deal]
Change the pick-up position to a new position where a head can move.
E3825 Station which can handle selected needle is not in the line.
"能处理选择针的位置不在线上."
[Cause]
Indicates that the needle specified in the adhesion data is not set for the applicator used on the line.
[Deal]
Look up the MSL setup for the needle setting of the applicator used on the line, or specify another
needle for the adhesion data.
E3826 The number of necessary resources in resource table has been exceeded.
"必须资源的数量在资源表中已经被超过."
[Cause]
Indicates that excessive number of resources are specified for the resource table.
[Deal]
Increase the number of the resources available for the resource table during the MSL setup.
E3827 Data mismatch as a line has completed normally.
"在数据一致性检查中未发现错误."
[Explanation]
The line consistency check has been completed successfully. Now, it is the time for optimizing. We
hope there occurs no error.
E3828 Error list file %s Do you want to see an error list?
"错误表文件 %s想要看错误表吗?"
[Explanation]
Appears when any error was found by the line consistency check. If "Yes" is pressed, the notepad
opens and the contents of the error is printed. If "No" is pressed, the prompt is erased.
E3829 Data mismatch as a line found ( %d errors )
"作为线数据不匹配( %d 错误)"
[Cause]
Appears if the line inconsistency check found an error.
[Deal]
Fix the error and restart the process.
W3830 Data mismatch as a line found ( %d warnings )
"作为线数据不匹配( %d 警告 )"
[Explanation]
Appears if executing the line consistency check founds an error.
E3831 Can not execute data mismatch check.
"不能执行数据匹配检查."
[Cause]
Memory space is not sufficient.
[Deal]
Quit other running applications, then restart it.
E3832 Can not execute NOTEPAD.
"不能激活记事本."
[Cause]
Memory space is not sufficient.
[Deal]
Quit other running applications, then restart it.
E3833 No station exists which can handle IC mark.
"没有位置存在能处理 IC 标记."
[Cause]
Indicates that there is none of 720, 730, 730plus, 740, 750,760 and 2000 series stations on the line,
but the mounting data uses the IC mark.
[Deal]
Add any of a 720, 730, 730plus 740, 750,760 and 2000 series station on the line during the MSL
setup.
E3834 IC mark data is assigned to the station which cannot handle it.
"IC 标记数据被分配在位置上,不能处理."
[Cause]
Appears if the specified station is none of 720, 730, 730plus, 740, 750,760 and 2000 series stations,
or is disabled in the unit status during the MSL setup.
[Deal]
Make sure that the specified station is the one available for the IC mark, or is not disabled in the unit
status during the MSL setup, and restart the process.
When checking the unit status of the MSL setup, check to see if the BOC camera is disabled for 720,
if OCC is disabled for 730, 730plus, 740, 750, and 760, and if OCC-L or OCC-R is disabled for 2010,
2020, 2030, and 2040.
E3835 Station which can handle MTC is not in the line.
" 能处理 MTC 的位置不在线."