JUKI贴片机错误代码.pdf - 第377页

“ 测定的电压 ( 单位 ) 有些异常。 ” [Cause] The unit for the voltage got ten from the tester is irregular. ‧The object(component) of the measurement is not contacting th e probe well. ‧Component Verification is broken. [Treatment] ‧P…

100%1 / 464
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690024 Something is wrong with the measured voltage
测定的电压有些异常。
[Cause]
The voltage gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690025 Something is wrong with the measured resistance(unit)
测定的电阻(单位)有些异常。
[Cause]
The unit for the resistance gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690026 Something is wrong with the measured volume(unit)
测定的电容(单位)有些异常。
[Cause]
The unit for the condenser capacity gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690027 Something is wrong with the measured voltage(unit)
测定的电压(单位)有些异常。
[Cause]
The unit for the voltage gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690028 Resistance can no be measured. | Please check if probe shuts down properly
不能测定电阻。|请检查探针是否已关闭。
[Cause]
The tester overflowed data when measuring the resistance.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690029 Volume can not be measured. | Please check if probe shuts down properly
不能测定电容。|请检查探针是否已关闭。
[Cause]
The tester overflowed data when measuring the condenser capacity.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690030 Voltage can not be measured. | Please check if probe shuts down properly
不能测定电压。|请检查探针是否已关闭。
[Cause]
The tester overflowed data when measuring the diode polarity.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690031 The power supply of the tester cannot be turned on.”
不能打开测试器电源。
E690032 Since air is falling, control of a probe is stopped.”
因为大气压太低,所以停止探针的控制。
E691001 Input/Output buffer status of CCL-48M does not get ready
CCL-48MI/O缓冲区不能达到就绪状态。
[Cause]
The input/output buffer status of the backup table counter(CCL-48M) does not get ready.
‧Backup table counter is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691002 Writing-in buffer of flush memory does not get useable
不能使用闪存卡的写入缓冲区。
[Cause]
'Writing-in' buffer did not get useable when checking its status after a 'writing-in' command to flush
memory was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.