JUKI贴片机错误代码.pdf - 第271页
Failed in IPC reception from the vi sion device driver. The vision device driver is HOLT. [Treatment] Please re-boot your machine. E630052 “ ViLib Ent ry: Error Execute Undefined Command ” “ ViLib 错误 :| 发现未定义命令代码 ” [Caus…
[Cause]
Failed to initialize a vision device driver internally.
Device manager did not get started properly.
[Treatment]
Please re-boot your machine.
E630010 “There is no empty space in the Vision Resource Semaphore”
“ViLib 错误:|没有信号登录”
[Cause]
A vision device driver did not get started properly.
You tried to get several vision device drivers started at one time.
[Treatment]
Please re-boot your machine.
E630011 “ViLib Thread: Failed in registration of bass interrupting”
“ViLib 错误:|总线中断的登录失败”
[Cause]
A vision device driver did not get started properly.
You tried to get several vision device drivers started at one time.
[Treatment]
Please re-boot your machine.
E630012 “ViLib Thread: Failed to open the serial port.”
“ViLib 错误:|打开串行端口失败。”
[Cause]
COM port does not return any response.
Another application is using COM port.
[Treatment]
Please re-start the application.
E630050 “ViLib Entry: IPC Send Error(Entry->Thread) occurred”
“ViLib 错误:|IPC 发送信息包错误(Entry->DriverThread)”
[Cause]
Failed in IPC transmission to the vision device driver.
The vision device driver is HOLT.
[Treatment]
Please re-boot your machine.
E630051 “ViLib Entry: IPC Receive Error(Entry<-Thread) occurred”
“ViLib 错误:|IPC 接收信息包错误(Entry<-DriverThread)”
[Cause]
Failed in IPC reception from the vision device driver.
The vision device driver is HOLT.
[Treatment]
Please re-boot your machine.
E630052 “ViLib Entry: Error Execute Undefined Command”
“ViLib 错误:|发现未定义命令代码”
[Cause]
You tried to execute an undefined vision command.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630053 “ViLib Thread: Undefined ViOS event is requested”
“ViLib 错误:|发现未定义 OS 事件要求”
[Cause]
You tried to issue an undefined vision event request.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630054 “ViLibError:| Command handshake error (skipped ACK).”
“ViLib 错误:|命令同步交换错误(Skipped ACK)”
E630073 “Vision Data: Ball patter has not been set yet”
“ViLib 错误:|没有设置球图案”
[Cause]
There is no ball patter data in the vision data.
[Treatment]
Please examine the production program.
Please re-load the production program.
E630074 “Camera scale has not been set yet”
“ViLib 错误:|没有设置摄像机缩放比例”
[Cause]
There are some items that have not been set yet in the Camera scaling in MS Parameter.
[Treatment]
Please examine the Camera scaling in MS Parameter.
E630075 “The window frame does not fit in the screen”
“ViLib 错误:|窗口框超出画面”
[Cause]
The component outer shape window frame does not fit in the screen if it is rotated to the tracing
posture.
[Treatment]
The component is too large to trace.
E630076 “ViLibError:| VCS program checksum error”
“ViLib 错误:|图像(VCS)程序的 Check-Sum 错误”
E630077 “ViLibError:| VCS program flash write error”
“ViLib 错误:|图像(VCS)程序的闪存卡写入错误”
E630078 “ViLibError:| VME bus power is cut off.”
“ViLib 错误:|VMEBus 电源被关闭”
E630080 Vision system error:| Vision system error: ACK Response Base (Vision command result error).”
“图像处理装置错误:|图像处理装置错误:ACK 应答 Base(图像命令的结果错误)”
E630081 “There is not valid mark within the detecting window”
“图像处理装置错误:|在窗口中没有发现标记”
[Cause]
The light is not ON.
There is no mark.
[Treatment]
Please examine if the light gets on properly.
Please change the coordinates to where a mark exists or move the mark detecting frame.
E630100 “Vision System: The parameter value is illegal”
“图像处理装置错误:|参数值错误”
[Cause]
You tried to send an illegal data to VCS.
[Treatment]
Please examine the parameter.
E630101 “Vision System: parameter count is wrong”
“图像处理装置错误:|参数个数错误”
[Cause]
The format of the command interface between the VCS and your machine is not correct.
Some program versions are clashing with each other.
[Treatment]