JUKI贴片机错误代码.pdf - 第216页

“ Z 轴移动前,查出了超过移动范围的指定坐标。 ” E610067 “ An error occur red when opening the ATC support plate .” “ 打开 ATC 滑板出错。 ” E610068 “ An error occur red when shutting the ATC support plate .” “ 关闭 ATC 滑板出错。 ” E610069 “ A t ime-out oc…

100%1 / 464
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610053 An error occurred when detecting the presence of Laser nozzle.”
检查吸嘴是否存在时发生错误。
E610054 Nozzle information (externals size of the nozzle) is not defined.”
吸嘴信(吸嘴外形大小)没有被定义。
E610055 Because the nozzle is too large, it is not possible to install in the MNLA head.”
因吸嘴过大,不能安装在 MNLA Head 上。
E610056 A large-scale nozzle cannot be installed in the MNLA head.”
MNLA Head 上,不能安装大型吸嘴。
E610057 The error occurred by the installation posture correction of the nozzle.”
校正吸嘴姿势出错。
E610058 The installation posture of the nozzle is abnormal.”
吸嘴安装姿势错误。
E610059 The nozzle is reversely installed in ATC.”
吸嘴倒立安装在 ATC
E610060 There is a possibility that parts arrive. |The nozzle cannot be returned.”
吸嘴上可能附有组件。|不能放回吸嘴。
E610061 The nozzle is too short. |Please check the nozzle.”
吸嘴过短。|请检查吸嘴。
E610062 Laser sensor might be dirty. |Please clean the sensor.”
激光传感器可能被弄脏。|请把传感器擦干净。
E610063 An error occurred when detecting the laser dirt.”
检查激光是否干净时,发生错误。
E610064 Laser sensor might be dirty. |Please clean the sensor.”
激光传感器可能被弄脏。|请把传感器擦干净。
E610065 An error occurred when detecting the laser dirt.”
检查激光是否干净时,发生错误。
E610066 Z Axis detect Cordinates outof Limit Range.”
Z 轴移动前,查出了超过移动范围的指定坐标。
E610067 An error occurred when opening the ATC support plate.”
打开 ATC 滑板出错。
E610068 An error occurred when shutting the ATC support plate.”
关闭 ATC 滑板出错。
E610069 A time-out occurred when opening the ATC(L) support plate.”
打开 ATC()滑板超时。
E610070 A time-out occurred when opening the ATC(R) support plate.”
关闭 ATC()滑板超时。
E610071 A time-out occurred when shutting the ATC(L) support plate.”
打开 ATC()滑板超时。
E610072 A time-out occurred when shutting the ATC(R) support plate.”
关闭 ATC()滑板超时。
E610073 ATC(L) support plate sensor is abnormal.”
ATC()滑板传感器异常。
E610074 ATC(R) support plate sensor is abnormal.”
ATC()板传感器异常。
E610075 ATC(L) support plate can not be shut down.”
不能关 ATC()滑板。
E610076 ATC(R) support plate can not be shut down.”
不能关 ATC()滑板。
E610077 The nozzle cannot be detected by measuring the length of the nozzle.|Please confirm the nozzle.”
测量吸嘴长度时,没有发现吸嘴。|请检查吸嘴
E610078 The length of the nozzle is too long.|Please confirm the nozzle.”
吸嘴长度过长。|请检查吸嘴。
E610079 The length of the nozzle is too short.|Please confirm the nozzle.”
吸嘴长度过短。|请检查吸嘴。
E610080 The nozzle is long and length is too long.|Please confirm the nozzle.”
吸嘴长度过长。|请检查吸嘴。
E610081 The length of the measured nozzle exceeds tolerance.|Please confirm the nozzle.”
吸嘴长度的测量结果超过允许范围。|请检查吸嘴。
E610082 The length of the measured nozzle does not fill tolerance.|Please confirm the nozzle.”
吸嘴长度的测量结果没有达到允许范围|请检查吸嘴。
E610083 The gotten nozzle width does not meet that of allocated nozzle.|The machine will not return the
nozzle.|Check condition of the nozzle.|Select <No> to return the nozzle.”
测定的吸嘴宽度与设置的吸嘴宽度不一致。|不能返回吸嘴。|选择〈否〉返回吸嘴。
E610084 A vacuum goes up too much. The nozzle may be choked up.|Please confirm the nozzle.”
真空过大。可能吸嘴被塞满。|请检查吸嘴。
E610085 Axes Driver:| XY-axis can not move.| Feeder float detected.”
XY 轴不能移动。|发现传送带浮动。
E610086 Axes Driver:| X-axis can not move.| Feeder float detected.”
X 轴不能移动。|发现传送带浮动。
E610087 Axes Driver:| Y-axis can not move.| Feeder float detected.”
Y 轴不能移动。|发现传送带浮动。
E610088 Axes Driver:| XR-axis can not move.| Feeder float detected.”
XR 轴不能移动。|发现传送带浮动。
E610089 Axes Driver:| YC-axis can not move.| Feeder float detected.”
YC 轴不能移动。|发现传送带浮动。
E610090 Axes Driver:| YR-axis can not move.| Feeder float detected.”
YR 轴不能移动。|发现传送带浮动。
E610091 The vacuum of a head did not go up.”
head 的真空没有上升。
E610092 Head is equipped with the nozzle of an exchange error.|Please check the wearing state of a nozzle.”
吸嘴发生交换错误。|请检查吸嘴的安装状态。
E610093 The head is equipped with the inaccurate nozzle.|Please confirm the nozzle.”
head 上安装的吸嘴错误。|请检查吸嘴。
E610100 The Vacuum calibration has not been installed
没有设置真空校准。
[Cause]
The installation position of the vacuum calibration has not been set.
[Treatment]