1) There is a possibility that the driving st ep motor is broken . It could be that the wiring came off the connector part, that a contact p in of the connector part is bro ken, that wiring got cut off, or that sensor it…

100%1 / 464
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650272 Clamp error : Time-out occurred while backup plate of the center station went up. The process is
forcibly terminated. Please remove on the conveying route
基板固定错误 :|中心缓冲区,支撑台上升超时。
[Cause]
The backup plate did not get to the aimed clamp height. As a cause, there is a possibility that the
firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650273 Clamp error : Backup plate of the center station went down illegally. The process is forcibly
terminated. Please remove on the conveying route
基板固定错误 :|中心缓冲区,支撑台下降失败。
[Cause]
The backup plate did not get down to the aimed height. This error usually occurs when there happens
a mechanical hindrance that prevents backup plate from going down. .
[Treatment]
1 If the backup table was going down when the error occurred.
There is an implement or some such between the backup table and a frame or mechanism underneath
it. Please examine if there is anything under the backup table.
2 Backup table went down at a high speed, and the continuous collision sound came out.
1) The encoder that decides a position of PWB may be broken. It could be that the wiring came off
the connector part, that a contact pin in the connector part is broken, that wiring got cut off, or that the
encoder itself is broken. Please examine the wiring and connector part If any of them are broken, you
need to replace them with new ones.
2) There is a possibility that the screw that holds the encoder and the encoder axis together is loose.
Please examine if the screw is tightened up enough.
3) If the treatments above do not work, PCB is broken or the wiring between the PCBs is bad.
3 The motor made a noise but the backup table did not come down.
There is a possibility that the up-and-down motion system under the backup table has a problem. The
timing belt, the screw that holds a belt pulley, or the screw that holds a motor may be loose. Please
see if the each part is tightened up enough.
4 The backup table did not come down and the motor did not make any noise.
1) There is a possibility that the driving step motor is broken. It could be that the wiring came off the
connector part, that a contact pin of the connector part is broken, that wiring got cut off, or that sensor
itself is broken. Please examine the wiring and connector part. If any of them are broken, you need to
replace them with new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650274 Clamp error : Time-out occurred while backup plate of the center station went down. The process is
forcibly terminated. Please remove on the conveying route
基板固定错误 :|中心缓冲区,支撑台下降超时。
[Cause]
The backup plate did not get down to the aimed clamp height. As a cause, there is a possibility that
the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650275 Clamp error : Something is wrong with the backup motor movement of the center station. The
process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|中心缓冲区,支撑台马达运转异常。
[Cause]
The backup plate did not get to the aimed clamp height. As a cause, there is a possibility that the
firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650276 Clamp error : Hole reference process at the center station finished illegally. The process is forcibly
terminated. Please remove on the conveying route
基板固定错误 :|中心缓冲区,孔基准动作异常。
[Cause]
The backup plate got to the aimed clamp height but the Ref. pin sensor did not get ON. This error is
likely to occur when the Ref. pin did not get in the positioning hole correctly.
[Treatment]
1 The Ref. pin is not in the positioning hole correctly.
Please set the positions of the Ref. pin and the follower pin correctly to the position of the Ref. Hole.
If you want to position PWBs with Outer shape Ref., please make sure that 'Outer shape Ref.' is
enabled in the PWB data in the Program Editor.
2 The Ref. pin is in the positioning hole correctly.
Select [Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of Ref. pin sensor in the 'Status' frame. Select 'backup plate'
in the 'Control item' on this screen to make the backup plate up and down. At this point, set the
Destination coordinates(up)(M) to -1.6mm.
1) When the Ref. pin sensor in the 'Status' frame does not get ON/OFF, there is a possibility that the
sensor is not installed properly. Please re-install the sensor to where it gets ON/OFF correctly.
2) When the Ref. pin sensor in the 'Status' frame does not get ON/OFF, there is a possibility that the
Ref. pin sensor is broken. It could be that the wiring came off the connector part, that a contact pin in
the connector part is broken, that wiring got cut off, or that sensor itself is broken. Please examine the
wiring and the connector. If any of them are broken, you need to replace them with new ones.
3) When the Ref. pin sensor in the 'Status' frame does get ON/OFF, there is a possibility that the
signal line of the Ref. pin sensor is broken. It could be that the wiring came off the connector part,
that a contact pin in the connector part is broken, or that the signal line got cut off. Please examine the
wiring and the connector. There also is another possibility that the screw that holds the encoder and
the encoder axis together is loose. Please make sure that the screw is tightened up enough.
4) If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E650277 Clamp Error :| Backup plate stopper of the center buffer lock up illegally.”
基板固定错误 :|中心缓冲区,支撑台制动器固定错误。
E650278 Clamp Error :| Backup plate stopper of the center buffer release illegally.”
基板固定错误 :|中心缓冲区,支撑台制动器释放错误。
E650281 Clamp error : Backup plate of the center station on the Entrance side went up illegally. The process
is forcibly terminated. Please remove on the conveying route
基板固定错误 :|入口侧中心缓冲区,支撑台上升失败。
[Cause]
The backup plate on the center station on the Entrance side did not get to the aimed clamp height.
This error usually occurs when there happens a mechanical hindrance to make the backup plate on the
center station on the Entrance side go up .
[Treatment]
1. If the backup table on the center station on the Entrance side was up when the error occurred.
1) Ref. pin or a follower pin (or both of them) on the center station on the Entrance side does not get