JUKI贴片机错误代码.pdf - 第417页

Appears if the mount position devi ates from the permissible ran ge of the PWB or cir cuit. On the left of a mounting data with deviate d position, "*" (out-of-range) m ark is added. [Deal] Specify the data wit…

100%1 / 464
E3010 Component ID is duplicated.
"组件 ID 被复制。"
[Cause]
Appears if an existing part ID is specified for the mounting data.
[Deal]
Specify a part ID not registered in the existing database.
E3011 '+ =' cannot be used on first line.
"'+='不能在第一线使用。"
[Cause]
Appears if a "+ ="(plus and equal) sign-set is used on the first line of the mounting data.
[Deal]
If data is entered with a "+ =" sign-set specified, the value on the current line is added with the value
on the above line. Use this sign-set on the second line or after.
E3012 '- =' cannot be used on first line.
"'-='不能在第一线使用。"
[Cause]
Appears if a "- ="(minus and equal) sign-set is used on the first line of the mounting data.
[Deal]
If data is entered with a "- =" sign-set specified, the value on the current line is added with the value
on the above line. Use this sign-set on the second line or after.
E3013 There are no data on line above this one.
"在该位置没有数据在线"
[Cause]
Appears if a "+ =" sign-set is used without specifying data at the current cursor position when
entering the mounting data.
[Deal]
Provide the data with a value.
E3014 Initial value has not been input.
"还未输入初值。"
[Cause]
Appears if a "+ =" sign-set is specified without specifying coordinates on the previous line.
[Deal]
Specify coordinates on the previous line.
E3015 Placement position is outside circuit PWB or circuit.
"贴片位置在电路基板和电路的外部"
[Cause]
Appears if the mount position deviates from the permissible range of the PWB or circuit. On the left
of a mounting data with deviated position, "*" (out-of-range) mark is added.
[Deal]
Specify the data within the permissible range of the PWB or circuit.
E3016 IC mark limits are exceeded.
"IC 标记限制超出。"
[Cause]
Appears if a value deviates from the permissible range indicated by the IC marks is specified for the
mounting data.
[Deal]
Specify the data within the permissible range.
E3017 Mark data are full.
"标记数据已满。"
[Cause]
Appears if mark data exceeding the maximum number (50 sets) is created for the mounting data.
[Deal]
Decrease the number of mark data to 50 sets or less.
E3018 Component data are full.
"组件数据已满。"
[Cause]
Appears if part names exceeding the maximum number is specified for the mounting data.
[Deal]
Decrease the number of part names (part data) to the maximum or less.
E3019 Component name cannot be found.
"未找到组件名称。"
E3020 Package has already been assigned.
"已指定包装。"
[Cause]
Appears if any position already allocated is claimed for the absorption data.
Message
E3021 There is no open lane.
"没有开放的信道。"
[Cause]
Appears if any number is specified for an absorption point where the stick package type has been
chosen for the part data, stations has been specified with the absorption data, and all lanes have been
preset.
[Deal]
Assign the stations with another absorption point and set lanes.
E3022 Tray holder registration is exceeded.
"托盘固定器注册过度。"
[Cause]
Appears if any number of holders exceeding the maximum for the absorption data.
[Deal]
Decrease the number of holders to the maximum or less.
E3023 Lane number does not match type.
"信道数量和类型不匹配。"
E3024 Type cannot be changed.
"不能改变类型。"
E3025 Cannot be assigned to type 1.
"不能指定为类型 1"
E3026 Lane cannot be assigned.
"信道不能被指定。"
E3027 Lane is already assigned.
"信道已经被指定。"
E3028 Number of leads is in error.
"引脚数量错误。"
E3029 umber missing is in error.
"缺省数量错误。"
[Cause]
Appears if any invalid value (exceeding the number of leads) is specified for the number of lead lacks
for the vision data editing.
[Deal]
Check the entered value.
E3030 Please input type.
"请输入类型。"
E3031 There is an error in the number of the first missing component.
"在第一个缺省组件处出现一个错误
."
[Cause]