2) If the treatment1 does not work, PCB is bro ken or the wiring between the PCBs is bad. E650272 “ Clamp error : Time-out occurred w hile backup plate of the cente r station went up. The process is forcibly terminated. …
E650266 “PWB Conveying Error :| Shutter time out error of OUT buffer.”
“传送基板错误 :|出口快门超时。”
E650267 “PWB Conveying Error :| C.OUT sensor ON detection error when OUT sensor ON is detected.”
“传送基板错误 :|OUT传感器ON时,发现C.OUT传感器ON错误。”
E650271 “Clamp error : Backup plate of the center station went up illegally. The process is forcibly
terminated. Please remove on the conveying route”
“基板固定错误 :|中心缓冲区,支撑台上升失败。”
[Cause]
The backup plate did not get to the aimed clamp height. This error usually occurs when there happens
a mechanical hindrance to make the backup plate go up.
[Treatment]
1 If the backup table was up when the error occurred.
1) Ref. pin or a follower pin (or both of them) does not get in a Ref. pin hole on the PWB. Please set
the positions of the Ref. pin and the follower pin correctly to the position of the Ref. Hole.
2) An implement or component got caught between the PWB and the center station. Please see if
there is anything to obstruct clamping between the PWB and the center station.
3) The backup pin is pushing up the back side of the PWB on which components are already mounted.
Please change the position of the backup pin to make it touch the PWB.
4) The thickness of PWB was set to significantly thin in the PWB data. Please re-enter the correct
thickness.
2 Backup table went up at a high speed, and the continuous collision sound came out.
1) The encoder that decides a position of PWB may be broken. It could be that the wiring came off
the connector part, that a contact pin in the connector part is broken, that wiring got cut off, or that the
encoder itself is broken. Please examine the wiring and connector part If any of them are broken, you
need to replace them with new ones.
2) There is a possibility that the screw that holds the encoder and the encoder axis together is loose.
Please examine if the screw is tightened up enough.
3) If the treatments above do not work, PCB is broken or the wiring between the PCBs is bad.
3 The motor made a noise but the backup table did not come up.
There is a possibility that the up-and-down motion system under the backup table has a problem. The
timing belt, the screw that holds a belt pulley, or the screw that holds a motor may be loose. Please
see if the each part is tightened up enough.
4 The backup table did not come up and the motor did not make any noise.
1) There is a possibility that the driving step motor is broken. It could be that the wiring came off the
connector part, that a contact pin of the connector part is broken, that wiring got cut off, or that sensor
itself is broken. Please examine the wiring and connector part. If any of them are broken, you need to
replace them with new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650272 “Clamp error : Time-out occurred while backup plate of the center station went up. The process is
forcibly terminated. Please remove on the conveying route”
“基板固定错误 :|中心缓冲区,支撑台上升超时。”
[Cause]
The backup plate did not get to the aimed clamp height. As a cause, there is a possibility that the
firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650273 “Clamp error : Backup plate of the center station went down illegally. The process is forcibly
terminated. Please remove on the conveying route”
“基板固定错误 :|中心缓冲区,支撑台下降失败。”
[Cause]
The backup plate did not get down to the aimed height. This error usually occurs when there happens
a mechanical hindrance that prevents backup plate from going down. .
[Treatment]
1 If the backup table was going down when the error occurred.
There is an implement or some such between the backup table and a frame or mechanism underneath
it. Please examine if there is anything under the backup table.
2 Backup table went down at a high speed, and the continuous collision sound came out.
1) The encoder that decides a position of PWB may be broken. It could be that the wiring came off
the connector part, that a contact pin in the connector part is broken, that wiring got cut off, or that the
encoder itself is broken. Please examine the wiring and connector part If any of them are broken, you
need to replace them with new ones.
2) There is a possibility that the screw that holds the encoder and the encoder axis together is loose.
Please examine if the screw is tightened up enough.
3) If the treatments above do not work, PCB is broken or the wiring between the PCBs is bad.
3 The motor made a noise but the backup table did not come down.
There is a possibility that the up-and-down motion system under the backup table has a problem. The
timing belt, the screw that holds a belt pulley, or the screw that holds a motor may be loose. Please
see if the each part is tightened up enough.
4 The backup table did not come down and the motor did not make any noise.
1) There is a possibility that the driving step motor is broken. It could be that the wiring came off the
connector part, that a contact pin of the connector part is broken, that wiring got cut off, or that sensor
itself is broken. Please examine the wiring and connector part. If any of them are broken, you need to
replace them with new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650274 “Clamp error : Time-out occurred while backup plate of the center station went down. The process is
forcibly terminated. Please remove on the conveying route”
“基板固定错误 :|中心缓冲区,支撑台下降超时。”
[Cause]
The backup plate did not get down to the aimed clamp height. As a cause, there is a possibility that
the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650275 “Clamp error : Something is wrong with the backup motor movement of the center station. The
process is forcibly terminated. Please remove on the conveying route”
“基板固定错误 :|中心缓冲区,支撑台马达运转异常。”
[Cause]
The backup plate did not get to the aimed clamp height. As a cause, there is a possibility that the
firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650276 “Clamp error : Hole reference process at the center station finished illegally. The process is forcibly
terminated. Please remove on the conveying route”
“基板固定错误 :|中心缓冲区,孔基准动作异常。”
[Cause]
The backup plate got to the aimed clamp height but the Ref. pin sensor did not get ON. This error is
likely to occur when the Ref. pin did not get in the positioning hole correctly.