Something was wrong with the cha racters when you hit Ent er key to define characters. [Treatment] Please re-enter charac ters E240008 “ There is no data previous ” “ 前面没有数据。 ” [Cause] This error occurs when there is no …
[Cause]
You could not move the Yc table.
Y 方向中心支撑台不能移动。
[Treatment]
Please check and see if the Yc table can move properly with Manual control.
请以“手动控制”检查 Yc 支撑台能不能正常活动。
E240003 “The axis margin out of range. It is not possible to operation”
“因超过范围,轴不能移动。”
[Cause]
You could not move the axis since it went out of its movable range.
因为轴移动位置超出活动范围,所以不能移到位。
[Treatment]
Please check and see if its coordinates are correct.
请检查坐标。
E240004 “The interrupt which was not able to operate was detected. | The trace is ended”
“发现不能动作的阻碍。|停止跟踪。”
[Cause]
The process was forcibly aborted since an interruption, such as axis alarm and Emergency STOP, that
stops every kind of actions was detected.
[Treatment]
Please check and see if any alarms occurred, and deal with causes of the alarm.
E240005 “The area sensor was detected. | Please remove the sensor reaction factor”
“因范围传感器发现错误而暂停。|请排除故障。”
[Cause]
Tracing got paused since the area sensor detected something.
[Treatment]
Please removed a factor detected by the sensor, and resume tracing.
E240006 “The feeder float sensor was detected. | Please remove the sensor reaction factor”
“发现传送带浮动。|请矫正传送带。”
[Cause]
Tracing got paused since the feeder float sensor detected something.
[Treatment]
Please removed a factor detected by the sensor, and resume tracing.
E240007 “Input is mistake”
“输入错误。”
[Cause]
Something was wrong with the characters when you hit Enter key to define characters.
[Treatment]
Please re-enter characters
E240008 “There is no data previous”
“前面没有数据。”
[Cause]
This error occurs when there is no data ahead to trace.
[Treatment]
Check only
E240009 “There is no data next”
“后面没有数据。”
[Cause]
This error occurs when there is no data behind to trace.
[Treatment]
Check only
E240010 “Specified device cannot be used”
“指定设备不能使用。”
[Cause]
The specified device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240011 “The station is different”
“站点不同。”
[Cause]
This error occurs when the side the HOD device is on is wrong when teaching.
[Treatment]
Please check and see which device (left or right) to use.
E240012 “Specified position not move”
“不能移到指定坐标。”
[Cause]
You could not move the axis to the specified position since the axis went out of its movable range.
[Treatment]
Please check and see if the coordinates are correct.
E240013 “The origin point return is non-completion”尚未结束返回原点。”
[Cause]
Home returning has not been complete yet.
[Treatment]
Please hit the ORIGIN button to perform the Home returning, and try the process again.
E240014 “The Left OCC device is set in unused by the setup”
“不能使用左 OCC。”
[Cause]
The Left OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240015 “The Right OCC device is set in unused by the setup”
“不能使用右 OCC。”
[Cause]
The Right OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240016 “The HMS device is set in unused by the setup”
“不能使用 HMS。”
[Cause]
The HMS device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240017 “The SOT direction inspection not execute.”
不能执行 SOT 方向检查。”
E240018 “The verification inspection not execute.”
“不能执行数值检查。”
E240019 “Area fiducial mark recognition error [ L side PWB / %d point]”
“基板基准标记识别错误[ 左侧基板 / 第%d 个点] “
E240020 “Area fiducial mark recognition error [ R side PWB / %d point]”
“基板基准标记识别错误[ 右侧基板 / 第%d 个点] “
E240021 “Device selection is mistake.”