JUKI贴片机错误代码.pdf - 第26页

Something was wrong with the cha racters when you hit Ent er key to define characters. [Treatment] Please re-enter charac ters E240008 “ There is no data previous ” “ 前面没有数据。 ” [Cause] This error occurs when there is no …

100%1 / 464
[Cause]
You could not move the Yc table.
Y 方向中心支撑台不能移动。
[Treatment]
Please check and see if the Yc table can move properly with Manual control.
请以“手动控制”检查 Yc 支撑台能不能正常活动。
E240003 The axis margin out of range. It is not possible to operation
因超过范围,轴不能移动。
[Cause]
You could not move the axis since it went out of its movable range.
因为轴移动位置超出活动范围,所以不能移到位。
[Treatment]
Please check and see if its coordinates are correct.
请检查坐标。
E240004 The interrupt which was not able to operate was detected. | The trace is ended
发现不能动作的阻碍。|停止跟踪。
[Cause]
The process was forcibly aborted since an interruption, such as axis alarm and Emergency STOP, that
stops every kind of actions was detected.
[Treatment]
Please check and see if any alarms occurred, and deal with causes of the alarm.
E240005 The area sensor was detected. | Please remove the sensor reaction factor
因范围传感器发现错误而暂停。|请排除故障。
[Cause]
Tracing got paused since the area sensor detected something.
[Treatment]
Please removed a factor detected by the sensor, and resume tracing.
E240006 The feeder float sensor was detected. | Please remove the sensor reaction factor
发现传送带浮动。|请矫正传送带。
[Cause]
Tracing got paused since the feeder float sensor detected something.
[Treatment]
Please removed a factor detected by the sensor, and resume tracing.
E240007 Input is mistake
输入错误。
[Cause]
Something was wrong with the characters when you hit Enter key to define characters.
[Treatment]
Please re-enter characters
E240008 There is no data previous
前面没有数据。
[Cause]
This error occurs when there is no data ahead to trace.
[Treatment]
Check only
E240009 There is no data next
后面没有数据。
[Cause]
This error occurs when there is no data behind to trace.
[Treatment]
Check only
E240010 Specified device cannot be used
指定设备不能使用。
[Cause]
The specified device is set to not use in the Use unit in Setup.
[Treatment]
If the device is available, please set it to use in the Use unit in Setup. If not, this procedure cannot
be executed.
E240011 The station is different
站点不同。
[Cause]
This error occurs when the side the HOD device is on is wrong when teaching.
[Treatment]
Please check and see which device (left or right) to use.
E240012 Specified position not move
不能移到指定坐标。
[Cause]
You could not move the axis to the specified position since the axis went out of its movable range.
[Treatment]
Please check and see if the coordinates are correct.
E240013 The origin point return is non-completion尚未结束返回原点。
[Cause]
Home returning has not been complete yet.
[Treatment]
Please hit the ORIGIN button to perform the Home returning, and try the process again.
E240014 The Left OCC device is set in unused by the setup
不能使用左 OCC
[Cause]
The Left OCC device is set to not use in the Use unit in Setup.
[Treatment]
If the device is available, please set it to use in the Use unit in Setup. If not, this procedure cannot
be executed.
E240015 The Right OCC device is set in unused by the setup
不能使用右 OCC
[Cause]
The Right OCC device is set to not use in the Use unit in Setup.
[Treatment]
If the device is available, please set it to use in the Use unit in Setup. If not, this procedure cannot
be executed.
E240016 The HMS device is set in unused by the setup
不能使用 HMS
[Cause]
The HMS device is set to not use in the Use unit in Setup.
[Treatment]
If the device is available, please set it to use in the Use unit in Setup. If not, this procedure cannot
be executed.
E240017 The SOT direction inspection not execute.”
不能执行 SOT 方向检查。
E240018 The verification inspection not execute.”
不能执行数值检查。
E240019 Area fiducial mark recognition error [ L side PWB / %d point]
基板基准标记识别错误[ 左侧基板 / %d 个点]
E240020 Area fiducial mark recognition error [ R side PWB / %d point]
基板基准标记识别错误[ 右侧基板 / %d 个点]
E240021 Device selection is mistake.”