JUKI贴片机错误代码.pdf - 第425页
[Explanation] Appears if the part type is chan ged to another part type for wh ich the verification is unavailable, with the verification enabled in the part data. W3525 Other station assignments of th is component will …
Appears if duplicating line is selected with the maximum amount of data having been specified for
the absorption data.
W3518 Program has been changed after optimization. Shall printing be continued?
"优化后程序已经被改变,继续打印吗?"
[Explanation]
Appears if printing is selected for data which have been edited after optimization.
W3519 Number of placements cannot exceed 10,000.
"贴片的数量不能超过 10,000 ."
[Explanation]
Appears if more than 10,000 mounting points are specified for the PWB data or mounting data.
W3520 Multiple pick data will be reduced to one by changing supply. Are you sure of changing supply?
"多重选择数据将由替换供给简化为一个,确定要替换供给?"
[Explanation]
Appears if the tray type is changed for the tray part for which more than one supply position have
been specified, in the part data.
E3521 This component already exists for a different type of station.
"因为位置的不同类型,该组件已经存在."
[Cause]
Appears if changing to a part is performed for which a different station is selected within the
mounting data.(Example of mounting data)
Part name StationA #2(710)
B #3(720)Appears if the part name A is replaced for A.
[Deal]
Change to another part name or select the same station.
E3522 Maximum data count exceeded! Data cannot be created.
"最大量数据计数超过,数据不能被创建。"
[Cause]
Appears if more than 3000 data is specified for the mounting data pasting.
[Deal]
Arrange the mounting data within 3000 data.
W3523 Editing will be discarded. Sure?
[Explanation]
Appears if another adhesion pattern name is selected when editing the application data for part data
application.
W3524 Verify will be unavailable. Sure?
[Explanation]
Appears if the part type is changed to another part type for which the verification is unavailable, with
the verification enabled in the part data.
W3525 Other station assignments of this component will also be changed.
[Explanation]
Appears if other stations having the same part in the mounting data are also to be changed.
E3526 <%s>Can not be changed as it already exieted.
[Cause]
Appears if changing to an existing part name is tried with "Edit (E)-Part Name Change (H)" on the
menu-bar.
[Deal]
Change to a new part name.
E3801 Station which do not use Shape Edge exists.
"不能使用外形边缘的位置存在."
[Cause]
Appears if 770, 710, or 720 is set for the line, but the item, BOC camera or BOC sensor, is disabled
in the unit status of the station profile during the MSL setup.
[Deal]
Enable the item, BOC camera or BOC sensor, in the unit status of the station profile during the MSL
setup.
E3802 Station which do not use BOC Camera ,BOC Sensor or OCC exists.
"不能使用 BOC 照相机 ,BOC传感器或 OCC 的位置存在."
[Cause]
Appears if, for all line stations, the BOC camera or BOC sensor is not set to be used at 710/720/770,
OCC is not set to be used at 730, 730plus/740, 750/760, and 775, OCC-L is not set to be used at 2010,
or OCC-L or OCC-R is not set to be used at 2020, 2030, and 2040, when PWB mark used?or Ckt.
mark is used?is specified at the OCC type?item.
[Deal]
Enable BOC sensor, BOC camera, OCC, OCC-L, or OCC-R in the unit status of the station profile of
the MSL setup.
E3803 Station which do not use Bad Mark Reader.
"位置不使用坏的标记读入."
[Cause]
Appears if the bad mark reader is disabled for the unit status of the station profile during the MSL
setup.
[Deal]
Enable the bad mark reader for the unit status of the station profile during the MSL setup.
E3804 No pick and place machine.
"没有选择和贴片机器!"
[Cause]
Appears if no mounter is set for line specified during the MSL setup, despite the "Only Mounting" or
"Mounting-Application" is set for the "Application/Mounting" in the mounting data.
[Deal]
Set a mounter on the line during the MSL setup or change the item. "Application/Mounting" to
"Only Application" in the mounting data.
E3805 No Adhesive dispenser.
"没有贴装分配!"
[Cause]
Appears if no dispenser is set on the line specified during the MSL setup, despite "Only Application"
or "Mounting-Application" is set for the "Application/Mounting" in the mounting data.
[Deal]
Set a dispenser on the line during the MSL setup or change the item. "Application/Mounting" to
"Only Mounting" in the mounting data.
E3806 Head can't move to placement position.
"贴片头不能移动到放置位置."
[Cause]
The component placement position is not within the area where a had can move.
[Deal]
Change the placement position within the area where a head can move.
E3807 Station which do not use IC or LAIC head in the line.
"在线上不能使用 IC 或 LAIC 头的位置."
[Cause]
Appears if 720 or 740 is specified for the line, but the item, IC or LAIC head, is disabled for the unit
status in the station profile of the MSL setup, or if a vision part is used without 720 or 740.
[Deal]
Enable the item, IC or LAIC head, in the unit status of the station profile during the MSL setup.
E3808 IC head or LAIC head cannot be used on selected station.
"IC 头或 LAIC 头在选择位置不能使用."
[Cause]
Although a 720, 740 or 760 is specified for the line, "Not used" is specified for the IC head or LAIC
head in the "Unit conditions" field of the "Station profile" window which is invoked from the MSL
Setup program.