“ 吸嘴长 度的测量结果超过允许范围。 | 请检查吸 嘴。 ” E610082 “ The lengt h of the measured nozzl e does not fill t olerance.|Plea se confirm the nozzle .” “ 吸嘴长 度的测量结果没有达到允许范围 。 | 请检查吸嘴。 ” E610083 “ The got ten nozzle width does not meet tha…

100%1 / 464
Z 轴移动前,查出了超过移动范围的指定坐标。
E610067 An error occurred when opening the ATC support plate.”
打开 ATC 滑板出错。
E610068 An error occurred when shutting the ATC support plate.”
关闭 ATC 滑板出错。
E610069 A time-out occurred when opening the ATC(L) support plate.”
打开 ATC()滑板超时。
E610070 A time-out occurred when opening the ATC(R) support plate.”
关闭 ATC()滑板超时。
E610071 A time-out occurred when shutting the ATC(L) support plate.”
打开 ATC()滑板超时。
E610072 A time-out occurred when shutting the ATC(R) support plate.”
关闭 ATC()滑板超时。
E610073 ATC(L) support plate sensor is abnormal.”
ATC()滑板传感器异常。
E610074 ATC(R) support plate sensor is abnormal.”
ATC()板传感器异常。
E610075 ATC(L) support plate can not be shut down.”
不能关 ATC()滑板。
E610076 ATC(R) support plate can not be shut down.”
不能关 ATC()滑板。
E610077 The nozzle cannot be detected by measuring the length of the nozzle.|Please confirm the nozzle.”
测量吸嘴长度时,没有发现吸嘴。|请检查吸嘴
E610078 The length of the nozzle is too long.|Please confirm the nozzle.”
吸嘴长度过长。|请检查吸嘴。
E610079 The length of the nozzle is too short.|Please confirm the nozzle.”
吸嘴长度过短。|请检查吸嘴。
E610080 The nozzle is long and length is too long.|Please confirm the nozzle.”
吸嘴长度过长。|请检查吸嘴。
E610081 The length of the measured nozzle exceeds tolerance.|Please confirm the nozzle.”
吸嘴长度的测量结果超过允许范围。|请检查吸嘴。
E610082 The length of the measured nozzle does not fill tolerance.|Please confirm the nozzle.”
吸嘴长度的测量结果没有达到允许范围|请检查吸嘴。
E610083 The gotten nozzle width does not meet that of allocated nozzle.|The machine will not return the
nozzle.|Check condition of the nozzle.|Select <No> to return the nozzle.”
测定的吸嘴宽度与设置的吸嘴宽度不一致。|不能返回吸嘴。|选择〈否〉返回吸嘴。
E610084 A vacuum goes up too much. The nozzle may be choked up.|Please confirm the nozzle.”
真空过大。可能吸嘴被塞满。|请检查吸嘴。
E610085 Axes Driver:| XY-axis can not move.| Feeder float detected.”
XY 轴不能移动。|发现传送带浮动。
E610086 Axes Driver:| X-axis can not move.| Feeder float detected.”
X 轴不能移动。|发现传送带浮动。
E610087 Axes Driver:| Y-axis can not move.| Feeder float detected.”
Y 轴不能移动。|发现传送带浮动。
E610088 Axes Driver:| XR-axis can not move.| Feeder float detected.”
XR 轴不能移动。|发现传送带浮动。
E610089 Axes Driver:| YC-axis can not move.| Feeder float detected.”
YC 轴不能移动。|发现传送带浮动。
E610090 Axes Driver:| YR-axis can not move.| Feeder float detected.”
YR 轴不能移动。|发现传送带浮动。
E610091 The vacuum of a head did not go up.”
head 的真空没有上升。
E610092 Head is equipped with the nozzle of an exchange error.|Please check the wearing state of a nozzle.”
吸嘴发生交换错误。|请检查吸嘴的安装状态。
E610093 The head is equipped with the inaccurate nozzle.|Please confirm the nozzle.”
head 上安装的吸嘴错误。|请检查吸嘴。
E610100 The Vacuum calibration has not been installed
没有设置真空校准。
[Cause]
The installation position of the vacuum calibration has not been set.
[Treatment]
If the vacuum calibration unit has not been installed on ATC, please install it.
You can set the installation position of the vacuum calibration as follows.
Please select [Machine Setup] from the menu bar, and then [Setting Group(G)] [ATC Nozzle
Allocation(A)]. If you right-click the mouse on the nozzle type of the ATC number on which the
vacuum calibration unit is installed, a list box is shown. Select 'Vac Unit' in there.
E610200 Emergency Stop SW occurred
发生紧急停止。
[Cause]
The Emergency Stop SW was pressed.
[Treatment]
Please unlock the Emergency Stop SW and hit the OK key.
E610201 Area sensor F ON occurred
发生范围传感器(前侧)启动。
[Cause]
The area sensor on the front side got ON.
[Treatment]
Please hit the OK key and then perform the Home returning.
E610202 Area sensor R ON occurred
发生范围传感器(后侧)启动。
[Cause]
The area sensor on the rear side got ON.
[Treatment]
Please hit the OK key and then perform the Home returning.
E610203 Cover open sensor ON occurred
机盖被打开。
[Cause]
The Safety cover is open.
[Treatment]
Please close the Safety cover.
E610204 Feeder floatation sensor ON occurred
发生传送带浮动传感器被启动。
[Cause]
The Feeder floatation sensor detected something.
[Treatment]
The error occurs when the Feeder floatation sensor is interrupted. If there is anything that interrupts
the sensor, please remove it.