JUKI贴片机错误代码.pdf - 第4页

E100103 “ You are trying to show the same language duplicately .” “ 显示语言有同样的语言。 ” E100104 “ Languages shown should come first .” “ 请填满语言选择按钮。 ” W100110 “ You made changes in Language Sel ection. Do you want to exit wit h…

100%1 / 464
第一章 程序管理
[程序管理、示教(坐标、标记)HLC 通讯]
E100010 Failed to initialize the Windows Socket
Windows Socket 初始化失败。|请关闭程序,重新启动
[Cause]
A critical error occurred while initializing the system.
系统初始化发生致命的错误。
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
退出所有程序,并关闭计算器后,重新启动主机。
If the error occurs even after the rebooting, there is a possibility that a system file is broken.
如果重新启动也发生同样错误,系统文件可能已破坏。
Please take a note of the error number and contact our technical service dept. for information.
请记好错误代码,并与代理店或本公司技朮服务部联系。
E100020 Failed to initialize OLE. | Confirm the OLE Library version
OLE 初始化失败。|请确认一下 OLE 程序库版本。
[Cause]
An error occurred while starting the axis control process.
启动轴控制程序发生错误。
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
退出所有程序,并关闭计算器后,重新启动主机。
If the error occurs even after the rebooting, there is a possibility that a system file is broken.
如果重新启动也发生同样错误,系统文件可能已破坏。
Please take a note of the error number and contact our technical service dept. for information.
请记好错误代码,并与代理店或本公司技朮服务部联系。
E100100 You have not selected a language.”
被设置为不能选择语言。
E100101 You chose a language(s) not supported by the OS.”
这个操作系统上不支持当前使用的语言。
E100102 You chose a language(s) not supported by the OS.”
这个操作系统上不支持当前显示语言。
E100103 You are trying to show the same language duplicately.”
显示语言有同样的语言。
E100104 Languages shown should come first.”
请填满语言选择按钮。
W100110 You made changes in Language Selection. Do you want to exit without saving these changes?
更新设置信息,是否不保存更新信息,退出语言设置?
E100111 You have not selected a language.”
没有选择显示语言。
E102010 Fatal system error occurred. | Abort the process
系统初始化失败。|请关闭程序,重新启动。
[Cause]
A critical error occurred while initializing the system.
系统初始化发生致命的错误。
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
退出所有程序,并关闭计算器后,重新启动主机。
If the error occurs even after the rebooting, there is a possibility that a system file is broken.
如果重新启动也发生同样错误,系统文件可能已破坏。
Please take a note of the error number and contact our technical service dept. for information.
请记好错误代码,并与代理店或本公司技朮服务部联系。
E102020You tried to start up, before the end of the previous system program.|Exit the system program, and
start again.”
程序被重复启动。|请关闭程序,重新运行。
[原因]
前一个主进程未完全结束,下一个主进程被启动。
[解决]
退出所有程序,并关闭计算器后,重新启动主机。
如果重新启动也发生同样错误,系统文件可能已破坏。
请记好错误代码,并与代理店或本公司技朮服务部联系。
E102100 There was a fatal failure while starting the KE-2000system. | Avoiding the possible damages, the
system is going to abort the process. (Error code = %d)
启动 KE-2000 系统时发生错误。|请关闭程序,重新启动。(错误代码 = %d )
[Cause]
A critical error occurred during the initialization.
初始化发生致命的错误。
The details of the error during the initialization are shown and the system is shut down.
显示初始化详细错误,并退出系统。
No: Detailed error code (Hexadecimal display)
No: 详细错误代码 (16进制显示)
0~3F: Failure count in creating flags to manage events
0 3F 创建处理事件标记失败数
40: Failure count in initializing IPC for internal communication
40 内部通讯用 IPC 的初始化失败。
100: MC starting error.
100 MC 起动错误
101: MC starting procedure 1 error
101 MC 起动过程 1 错误
102: MC starting procedure 2 error
102 MC起动过程 2 错误
103: MC starting procedure 3 error
103 MC起动过程 3 错误
104: MC starting procedure 4 error
104 MC起动过程 4 错误
105: MC starting procedure 5 error
105 MC起动过程 5 错误
106: TIME-OUT of driver initialization   5min.
106 驱动器初始化超时(5 分)
107: TIME-OUT of the main process initialization on the MC side.
107 MC主进程初始化超时
200: MC presence check.
200 检查 MC 是否存在
401: Failure in creating memory for design value data.
401
建立设计值数据内存失败
402: Failure in creating memory for MS parameter
402 建立 MS 参数内存失败
403: Failure in creating memory for Mech. Control parameter.
403 建立机器控制参数用内存失败
404: Failure in creating memory for Mech.-pos.
404 建立机器位置用内存失败
405: Failure in creating memory for the operation options.
405 建立操作选项用内存失败
406: Failure in creating memory for Setup data.