JUKI贴片机错误代码.pdf - 第416页
E3010 Component ID is duplicated. " 组件 ID 被复制。 " [Cause] Appears if an existing part ID is specified for t he mounting da ta. [Deal] Specify a part ID not registere d in the existing database. E3011 '+ =&a…
Load a valid file.
E3005 Cannot be deleted.
"不能被删除。"
[Cause]
Appears if deleting a component with which linkage is established is tried.
[Deal]
Make sure that no linkage is established with the data to delete, and restart the process.
E3006 Circuit protrudes from circuit PWB.
"电路从电路基板上突出了."
[Cause]
Appears if an entered value deviates from the permissible range of the PWB.
[Deal]
Make sure that the value is specified within the permissible range of the PWB, and restart the
process.
E3007 BOC mark limits are exceeded.
"BOC 标记限制过度。"
[Cause]
Appears if the specified PWB data deviates from the permissible entry range indicated by the BOC
marks.
[Deal]
Make sure that the value is specified within the permissible range indicated by the BOC marks, and
restart the process.
E3008 Bad mark limits are exceeded.
"错误标记限制过度。"
[Cause]
Appears if an entered value deviates from the permissible range indicated by the bad marks.
[Deal]
Make sure that the value is specified within the permissible range indicated by the bad marks, and
restart the process.
E3009 Circuit layout data have not been input, so input is not possible.
"电路设置数据不能输入,所以不能输入。"
[Cause]
Appears if mark data is tried to be entered with "No Matrix" selected for the PWB data, and no data
entered for the circuit arrangement.
[Deal]
Provide the circuit arrangement in the PWB data with data, and reenter the mark data.
E3010 Component ID is duplicated.
"组件 ID 被复制。"
[Cause]
Appears if an existing part ID is specified for the mounting data.
[Deal]
Specify a part ID not registered in the existing database.
E3011 '+ =' cannot be used on first line.
"'+='不能在第一线使用。"
[Cause]
Appears if a "+ ="(plus and equal) sign-set is used on the first line of the mounting data.
[Deal]
If data is entered with a "+ =" sign-set specified, the value on the current line is added with the value
on the above line. Use this sign-set on the second line or after.
E3012 '- =' cannot be used on first line.
"'-='不能在第一线使用。"
[Cause]
Appears if a "- ="(minus and equal) sign-set is used on the first line of the mounting data.
[Deal]
If data is entered with a "- =" sign-set specified, the value on the current line is added with the value
on the above line. Use this sign-set on the second line or after.
E3013 There are no data on line above this one.
"在该位置没有数据在线"
[Cause]
Appears if a "+ =" sign-set is used without specifying data at the current cursor position when
entering the mounting data.
[Deal]
Provide the data with a value.
E3014 Initial value has not been input.
"还未输入初值。"
[Cause]
Appears if a "+ =" sign-set is specified without specifying coordinates on the previous line.
[Deal]
Specify coordinates on the previous line.
E3015 Placement position is outside circuit PWB or circuit.
"贴片位置在电路基板和电路的外部。"
[Cause]
Appears if the mount position deviates from the permissible range of the PWB or circuit. On the left
of a mounting data with deviated position, "*" (out-of-range) mark is added.
[Deal]
Specify the data within the permissible range of the PWB or circuit.
E3016 IC mark limits are exceeded.
"IC 标记限制超出。"
[Cause]
Appears if a value deviates from the permissible range indicated by the IC marks is specified for the
mounting data.
[Deal]
Specify the data within the permissible range.
E3017 Mark data are full.
"标记数据已满。"
[Cause]
Appears if mark data exceeding the maximum number (50 sets) is created for the mounting data.
[Deal]
Decrease the number of mark data to 50 sets or less.
E3018 Component data are full.
"组件数据已满。"
[Cause]
Appears if part names exceeding the maximum number is specified for the mounting data.
[Deal]
Decrease the number of part names (part data) to the maximum or less.
E3019 “Component name cannot be found. “
"未找到组件名称。"
E3020 Package has already been assigned.
"已指定包装。"
[Cause]
Appears if any position already allocated is claimed for the absorption data.
Message
E3021 There is no open lane.
"没有开放的信道。"
[Cause]
Appears if any number is specified for an absorption point where the stick package type has been
chosen for the part data, stations has been specified with the absorption data, and all lanes have been