JUKI贴片机错误代码.pdf - 第195页

‧If the treatment1 does not work, a PCB i s broken or the wiring between the PCBs is bad. E610008 “ ATC(R) sli de pate sensor is abnormal ” “ ATC( 右 ) 滑板传感器异常。 ” [Cause] The status of the slide plate ON sensor or OFF sen…

100%1 / 464
‧There is a possibility that the air supplying pipes to the slide plate driving cylinder have a problem.
It could be that the speed controller is fully tightened up, that the air pipe came off the cylinder, or a
wrong air pipe is connected to the cylinder. Please see the air pipes and make sure that correct pipes
are connected.
‧There is a possibility that the connecting part between the shaft of the slide plate driving cylinder
and the slide plate has a problem. It could be that the nut attached to the tip of the shaft fell off, that
the shaft got chipped or broken, or that the plate got chipped or broken. You need to have the
damaged part repaired or replace it with a new one.
‧There is a possibility that the slide plate driving cylinder is broken. Please stop the air supplying on
the machine and see if the slide plate works fine manually. If the plate does not work smoothly, you
need to replace it with a new one.
‧There is a possibility that the slide plate driving solenoid valve is broken. It could be that the
wiring came off the connector part, that a contact pin in the connector part is broken, that the wiring
got cut off, or the solenoid valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
‧If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E610007 ATC(L) slide plate sensor is abnormal
ATC()滑板传感器异常。
[Cause]
The status of the slide plate ON sensor or OFF sensor of the left ATC slide plate is abnormal. The
slide plate ON sensor and OFF sensor got ON at the same time.
[Treatment]
Please select [Manual Control] from the menu bar, and then select [Control(C)] [Other(O)][ATC
Control(A)]. Set 'Control Unit' to 'left ATC', and select 'Slide plate Control(A)' from the 'Control Item'
frame' to open/close the slide plate. Please perform one of the treatments below according to the result
you get.
1. 'Slide plate ON sensor' and 'Slide plate OFF sensor' in the 'Status' displaying frame both get
ON/OFF.
‧Slide plate ON sensor or Slide plate OFF sensor, or both, is on the wrong position. There is a
possibility that the sensors are too close to each other, so widen the distance between the two.
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
2. Either one of 'Slide plate ON sensor' or 'Slide plate OFF sensor' in the 'Status' displaying frame is
always ON.
‧There is a possibility that the slide plate ON sensor or OFF sensor is broken. It could be that the
wiring came off the connector part, that a pin in the connector part is broken, that the wiring got cut
off, or the sensor itself is broken. Please examine the wiring and the connector. If any of them are
broken, you need to replace them with new ones.
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
E610008 ATC(R) slide pate sensor is abnormal
ATC()滑板传感器异常。
[Cause]
The status of the slide plate ON sensor or OFF sensor of the right ATC slide plate is abnormal. The
slide plate ON sensor and OFF sensor got ON at the same time.
[Treatment]
Please select [Manual Control] from the menu bar, and then select [Control(C)] [Other(O)][ATC
Control(A)]. Set 'Control Unit' to 'right ATC', and select 'Slide plate Control(A)' from the 'Control
Item' frame' to open/close the slide plate. Please perform one of the treatments below according to the
result you get.
1. 'Slide plate ON sensor' and 'Slide plate OFF sensor' in the 'Status' displaying frame both get
ON/OFF.
‧Slide plate ON sensor or Slide plate OFF sensor, or both, is on the wrong position. There is a
possibility that the sensors are too close to each other, so widen the distance between the two.
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
2. Either one of 'Slide plate ON sensor' or 'Slide plate OFF sensor' in the 'Status' displaying frame is
always ON.
‧There is a possibility that the slide plate ON sensor or OFF sensor is broken. It could be that the
wiring came off the connector part, that a pin in the connector part is broken, that the wiring got cut
off, or the sensor itself is broken. Please examine the wiring and the connector. If any of them are
broken, you need to replace them with new ones.
‧If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
E610009 Parameter for the head is not correct
Head 的参数不正确。
[Cause]
Head specifying is abnormal. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610010 The specified cylinder does not exist
指定圆筒不存在。
[Cause]
The specifying of ATC position is abnormal. The data in the machine is broken or the version of the
software that is installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610011 An error occurred when starting XY axes movement
XY 轴移动开始时发生错误
[Cause]
An error occurred when starting XY axes movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610012 An error occurred when starting X axis movement
X 轴移动开始时发生错误
[Cause]
An error occurred when starting X axis (left side) movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610013 An error occurred when starting XR axis movement
XR 轴移动开始时发生错误
[Cause]
An error occurred when starting X axis (right side) movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610014 An error occurred when starting Y axis movement
Y 轴移动开始时发生错误
[Cause]
An error occurred when starting Y axis movement.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610015 An error occurred when starting Z axis movement
Z 轴移动开始时发生错误
[Cause]
An error occurred when starting X axis (nozzle up-and-down axis) movement.