JUKI贴片机错误代码.pdf - 第364页

station because the PWB has ho les on it or the edge of the PWB is chipped. Please select [Set up(S)] [Setup(S)] from the menu bar, and then sel ect [Setting Group(G) ] [PWB conveyor(C)]. Set 'Delay for conveyor sen…

100%1 / 464
The STOP sensor on the center station on the Exit side is not detecting the PWB. Please select
[Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of the STOP sensor in the 'Status' frame.
1) The sensitivity of the STOP sensor on the center station on the Exit side may be too low. Please
re-adjust the sensitivity of the sensor, using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor on the center station on
the Exit side is broken. It could be that the wiring came off the connector part, that a contact pin in
the connector part is broken, that wiring got cut off, or that the sensor itself is broken. Please examine
the wiring and the connector. If any of them are broken, you need to replace them with new ones.
3) If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650355 Idle PWB Conveying Error :| PWB conveying error of the center buffer on the Exit side. | Please
remove it.”
传送基板(通过)错误 :|在出口侧中心缓冲区发生错误
E650362 Idle PWB Conveying Error :| OUT sensor OFF detection time out error. | Please remove it.”
传送基板(通过)错误 :|OUT传感器OFF超时。
E650364 Idle PWB Conveying Error : PWB conveying time out error of Output buffer. The process is
forcibly terminated. Please remove on the conveying route
传送基板(通过)错误 :|基板移出出口缓冲区超时。
[Cause]
This error occurred because the OUT sensor on the OUTPUT buffer did not get ON even thought a
certain amount of time has passed since the C-OUT sensor on the center station got OFF when
conveying a PWB on the center station to the OUTPUT buffer. Usually, this error occurs when a
PWB can not go through the conveyor for some reason.
[Treatment]
1 If the PWB was on the position where it is NOT detected by the C-OUT sensor on the center
station or the OUT sensor on the OUTPUT buffer when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the error occurred because the conveying belt on the center station stopped and the PWB did
not get conveyed out when conveying the PWB on the center station.
The error occurs if the C-OUT sensor gets temporarily OFF before the PWB has gone through the
station.
1) The error occurs if the C-OUT sensor gets temporarily OFF when the PWB has gone through the
station because the PWB has holes on it or the edge of the PWB is chipped. Please select [Setup(S)]
[Setup(S)] from the menu bar, and then select [Setting Group(G)] [PWB conveyor(C)]. Set 'Delay for
conveyor sensor' to disable the holes or chips on PWBs.
2) The error occurs if C-OUT sensor temporarily gets OFF because the PWB has a part that fully
reflects. This error is likely to occur when you use boards such as metal jig board. As a treatment,
please set 'Delay for conveyor sensor', following the steps mentioned in the treatment1.
3 If the belt was moving for a while after the PWB got to the PUT sensor when the error
occurred.
The OUT sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
OUT sensor on the center station on the Exit side in the 'Status' frame.
1) The sensitivity of the OUT sensor may be too low. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the OUT sensor is broken. It could be
that the wiring came off the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
3) If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650365 Idle PWB Conveying Error : PWB conveying time out error of Output buffer. The process is
forcibly terminated. Please remove on the conveying route
传送基板(通过)错误 :|基板移出出口缓冲区超时。
[Cause]
The error occurs when letting a PWB on the OUTPUT buffer go based on a PWB request signal sent
from a machine in the lower part of the line, but the OUT sensor does not get OFF after a certain
amount of time has passed since the sensor got OFF and then ON again. Usually, this error occurs
when a PWB can not go through the INPUT buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by the OUT sensor when the error
occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the lower part of the line. Please re-adjust the connection.
2) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
3) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by the OUT sensor when the error
occurred.
If the OUT sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
OUT sensor in the 'Status' frame.
1) If there is anything that OUT sensor reacts to underneath the OUT sensor, please remove it from
under the sensor or change the position of the sensor.
2) If the treatment1 does not work, please re-adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the OUT sensor is broken. It could be
that the wiring came off the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that the sensor itself is broken. Please examine the wiring and the connector. If
any of them are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650366 Idle PWB Conveying Error :| Shutter time out error of Output buffer. | Please remove it.”
传送基板(通过)错误 :|出口快门超时。
E650367 Idle PWB Conveying Error :| PWB conveying error of Output buffer. | Please remove it.”
传送基板(通过)错误 :|出口缓冲区的基板搬入出错。
W650401 Clamp error :| Backup plate stopper is ON. | Please Turn Off Backup plate stopper.”
基板固定错误 :|支撑台停止挡销被打开。|请关闭支撑台停止挡销。
W650402 Clamp error :| Backup plate stopper is specification not used.”
基板固定错误 :|支撑台停止挡销没有被选用。
W650421 Clamp error :| Backup plate stopper is ON. | Please Turn Off Backup plate stopper.”
基板固定错误 :|入口侧中心缓冲区的支撑台停止挡销被打开。|请关闭支撑台停止挡销。
W650422 Clamp error :| Backup plate stopper is specification not used.”
基板固定错误 :|入口侧中心缓冲区的支撑台停止挡销没有被选用。
W650423 Clamp error :| In buffer is specification not used.”
基板固定错误 :|入口侧中心缓冲区没有被选用。
W650441 Clamp error :| Backup plate stopper is ON. | Please Turn Off Backup plate stopper.”
基板固定错误 :|出口侧中心缓冲区的支撑台停止挡销被打开。|请关闭支撑台停止挡销。
W650442 Clamp error :| Backup plate stopper is specification not used.”
基板固定错误 :|出口侧中心缓冲区的支撑台停止挡销没有被选用。
W650443 Clamp error :| Out buffer is specification not used.”