“ 不存 在 SOT 方向检查器。 ” E241701 “ The SOT direction inspection stage is an unuse unit .” “ SOT 方向 检查器没有被选用。 ” E241702 “ The inspection error occurred .” “ 检查发 生错误。 ” E241703 “ The component size is out of range .” “ 组件大 小超出检…

100%1 / 464
calculated one?
根据测量组件大小结果,算出的激光高度和当前的值不相同。|是否更新?
Q241311 “The automatically tombstone height is different from the current value.|Change to the calculated
one?
根据测量组件大小结果,算出的芯片站立判断高度和当前的值不相同。|是否更新?
E241500 There is no verification device
不存在数值检查装置。
[Cause]
Verification cannot be performed since there is no verification device installed.
[Treatment]
Please check the installation of the verification device (an option in MS parameter).
E241501 The verification device is an unused unit
数值检查装置没有被选用。
[Cause]
Verification cannot be performed since the verification device is set to not use.
[Treatment]
Please check the use status of the device (the Use unit in the Machine Setup).
E241502 Supply of the component is no CVS
不存在适用 CVS 的组件。
[Cause]
You are trying to verify a component that is not set to 'Verification' in the Expansion screen in Editor.
[Treatment]
Please set necessary items (Expansion screen in the Edit and Component data) for the Verification.
E241503 The inspection error occurred
检查发生错误。
[Cause]
This message appears to inform you that an error occurred during the Verification single inspection.
[Treatment]
Please press 'OK' button.
E241600 Centering of the component is no vision.”
不属于外形定中心组件。
E241650 Centering of the component is no lsc.”
不属 LSC 定中心组件。
E241700 There is no SOT direction inspection stage.”
不存 SOT 方向检查器。
E241701 The SOT direction inspection stage is an unuse unit.”
SOT 方向检查器没有被选用。
E241702 The inspection error occurred.”
检查发生错误。
E241703 The component size is out of range.”
组件大小超出检查范围。
Q241800 %s|The optimum value of lighting data was acquirable.|(The basis in a prenthesis)|Is lighting data
updated?
%s|得到照明数据的优化(括号内的是过去值)| 是否更新照明数据?
E241801 The optimum value of lighting data was unacquirable.”
不能取得照明数据的优化值。
Q241802 %sThe optimum value of light was acquirable.|(The basis in a prenthesis)|There is the influence of
inspection.Is lighting data updated? 取得照明数据的优化值(括号内的是过去值)|BGA
件的时候, 有时对检查精度有影响。|是否更新照明数?
E241900 Coplanarity inspection is not specified.”
没有指定共面检测器。
E241901 Coplanarity data was unacquirable. |Please confirm the height of component and lead width.”
不能取得共面参数。|请确认一下组件高度和电极宽度。
Q241902 E.Brighthess Threshold %s (%s)|Scanning Offset %s (%s)|The optimum value of coplanarity
parameters was acquirable.|Is coplanarity parameters updated?
电极亮度阈值 %s (%s)|扫描位置的偏差 %s (%s)| 得到共面参数的优化值,是否更新参
数?
E241903 Centering of the component is no vision or lsc.”
不属于外形定中心或 LSC 定中心的组件
E242500 The origin point return does not end.|Please retry after completing the origin point return.”
未结束返回原点。|返回原点结束后,请再次运行。
E242501 The servo motor is free.|Please retry after releasing the servo free state.”
伺服马达处于未起动状态。|请起动伺服马达后,再次运行。
E242502 Axis movement error (XY axis limit error)
轴移动发生错误(XY 轴界限错误)
E242503 Axis movement error (YC axis limit error)
轴移动发生错误(YC 轴界限错误)
E242504 Axis movement error (Z axis limit error)
轴移动发生错误(Z 轴界限错误)
E242505 Axis movement error (T axis limit error)
轴移动发生错误(T 轴界限错误)
E242506 Axis movement error (XY axis driver error)
轴移动发生错误(XY 轴驱动错误)
E242507 Axis movement error (YC axis driver error)
轴移动发生错误(YC 轴驱动错误)
E242508 Axis movement error (Z axis driver error)
轴移动发生错误(Z 轴驱动错误)
E242509 Axis movement error (T axis driver error)
轴移动发生错误(T 轴驱动错误)
E242510 The vacuum pressure cannot be measured.”
取得真空压发生错误。(I/O 驱动错误)
E242511 No component.(Retry over of picking.)|Please confirm the existence of components.”
无组件(重试结束)|请确认一下组件是否存在。
E242512 Laser measurement error (ONCE measurement) | Code = %d (Please refer to the operation
manual.)
激光测量发生错误(ONCE 测量) | 代码 = %d (请查阅操作手册。)
E242513 Laser measurement error (Height measurement) | Code = %d (Please refer to the operation
manual.)
激光测量发生错误(高度测量) | 代码 = %d (请查阅操作手册。)
E242514 Laser measurement error (SWEEP measurement) | Code = %d (Please refer to the operation
manual.)
激光测量发生错误(SWEEP 测量) | 代码 = %d (请查阅操作手册)
E242515 There is no %d nozzle.
%d 号吸嘴不存在。
E242516 The nozzle cannot be returned.
归还吸嘴失败。