JUKI贴片机错误代码.pdf - 第229页
‧If the error occurred after th e installati on or the version up of the software, you need t o re-install the software. ‧If the treatments above do not work, there is a possibility t h at board(s) i n the machine is bro…
“发生 RT3 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head3 with a new one.
E610243 “RT4 Driver alarm occurred”
“发生 RT4 驱动警报。”
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head4 with a new one.
E610244 “XH Driver alarm occurred.”
“发生 XH 驱动警报。”
E610245 “The power supply OFF of a VME bus occurred.”
“发生 VME 的断电。”
E610246 “Power OFF occurred.”
“发生停电。”
E610247 “XY limit occurred.”
“发生 XY 超界。”
E610248 “ZT limit occurred.”
“发生 Zθ超界。”
E610249 “XY Driver alarm occurred.”
“发生 XY 驱动警报。”
E610300 “An error occurred when ComRes command send”
“发送 COMRES 命令出错。”
[Cause]
Command sending of Command-response type failed. This is an error that occurred during the data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610301 “An error occurred when ComRes response receive”
“接受 COMRES 应答出错。”
[Cause]
Response reception of Command-Response type failed. This is an error that occurred during the data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧ If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610302 “Z movement place parameter is not correct.”
“Z 移动地点参数不正确。”
E610303 “T movement place parameter is not correct.”
“T 移动地点参数不正确。”
E610304 “The timeout occurred in the waiting for an event.”
“发生事件等待错误。”
E610305 “The error occurred in event issue.”
“发生事件发行错误。”
E610400 “Vacuum of L1 head has been on”
“L1 Head 真空被打开。”
[Cause]
A nozzle returning was requested while the vacuum of the left head1 is still ON. There is a possibility
that a component is being picked by the head.
左 Head1 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610401 “Vacuum of L2 head has been on”
“L2 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the left head2 is still ON. There is a possibility
that a component is being picked by the head.
左 Head2 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610402 “Vacuum of L3 head has been on”
“L3 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the left head3 is still ON. There is a possibility
that a component is being picked by the head.
左 Head3 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610403 “Vacuum of L4 head has been on”
“L4 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the left head4 is still ON. There is a possibility
that a component is being picked by the head.
左 Head4 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610404 “Vacuum of R1 head has been on”
“R1 Head 真空被启动。”
[Cause]
A nozzle returning was requested while the vacuum of the right head1 is still ON. There is a
possibility that a component is being picked by the head.
右 Head1 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 上有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610405 “Vacuum of R2 head has been on”
“R2 Head 真空被启动。”
[Cause]