JUKI贴片机错误代码.pdf - 第461页
" 电路数量超出范围 ." [Cause] The maximum number of circuits available for this li ne was exce eded. [Deal] Decrea se the data (number of PWB data circuits) to the lim it o r less. E6902 Needle number Error. " 针数量…
[Cause]
The %dth part data is incomplete.
[Deal]
Complete the part data.
E6813 Adhesion data at %d position is not completed.
"在%d 位置的贴装数据不完全。"
[Cause]
The %dth adhesion data is incomplete.
[Deal]
Complete the adhesion data.
E6814 Station data at %d position is not completed.
"在%d 位置放置数据不完全。"
[Cause]
The %dth station data is incomplete.
[Deal]
Complete the station data.
E6821 A system error occurred in dispenser division.
"分配划分出现一个系统错误."
[Cause]
The numbers of the needles and stations are not corresponding with each other.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6822 Needle setting of data at %d position is abnormal.
"在%d 位置针设置数据不正常."
[Cause]
The needle type for the specified station is different from the needle type for the adhesion data.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6900 Insufficient memory in optimization.
"优化时内存不足."
[Cause]
Indicates insufficient free space in the memory.
[Deal]
Exit from other applications and retry the process.
E6901 Circuit number is out of range.
"电路数量超出范围."
[Cause]
The maximum number of circuits available for this line was exceeded.
[Deal]
Decrease the data (number of PWB data circuits) to the limit or less.
E6902 Needle number Error.
"针数量错误."
[Cause]
The needle type for the specified station is different from that for the adhesion data.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6903 Head number undefined Error.
"贴装头数量未定义."
[Cause]
A failure was found in the data.
[Deal]
Correct the data (adhesion data needle) specification.
E6904 Head number Error.
"贴装头的数量错误."
[Cause]
The head to use is disabled.
[Deal]
Start the MST setup to enable the needle.
E6905 Placement position is out of range.
"贴片位置超过范围."
[Cause]
Excessive mounting data were specified.
[Deal]
Decrease the mounting data to the limit or less.
E6906 Internal Error.
"内部错误."
[Cause]
EPU770 (Hlc Div Dispensor Optimize) error return values, -2, -3, -4
[Deal]
Consult the manufacturer.
E6907 Adhesive data not complete yet.
"贴装数据不完全."
[Cause]
There is incomplete adhesion data.
[Deal]
Correct the data (adhesion) specification.
E8001 “No protect module! “
"无保护模式!"
E8002 “Product planning cannot run with MSL Setup simultaneously. “
"生产计划不能和 MSL 设置同时运行。"
E8003 “Product reservation file cannot be opened, as the reserved file or files could not be found. “
"产品保留文件不能打开, 找不到保留文件。"
W8004 “If you change the product reservation, you have to close all the window and re-optimize because
the previous optimization file will not match. “
"如果要改变产品保留,你必须关闭所有窗口和重新优化因为以前的优化文件不匹配。"
E8005 "Write protected! “
"写保护!"
E8006 “Illegal data input! “
"输入的非法数据!"
E8007 “No displayable data. window cannot be opened. “
"没有可显示数据,窗口不能打开。"
E8008 “Optimization cannot be excuted, bacause the line configuration mismatches between program file
and MSL-setup. You need to change your program file. “
"优化不能执行,因为在程序文件和 MSL-设置之间的线结构不匹配。"