JUKI贴片机错误代码.pdf - 第330页

the PWB when the error occurred. 1) If it is possible to change the stop posi tion on the machine in the upper part of the line, please make a modification not to make a PWB overrun to get detected b y the IN sensor. 2) …

100%1 / 464
not deal with PWB that is over 510mm
2 The PWB was staying on the position where IN sensor detected the PWB when the error
occurred (the error occurred before the PWB got to the WAIT sensor).
There is a possibility that the WAIT sensor detected something while the PWB was conveyed to the
Input buffer. Please select [Manual Control] from the menu bar, and then select [Control(C)]
[Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of WAIT sensor in the 'Status'
frame.
1) If the light transmitter(LED) and light receiver(PT) of the wait sensor are not on the right positions,
please adjust them to make a correct alignment between them.
2) If the sensitivity of the WAIT sensor is not fine, please re-adjust it (The sensitivity of the sensor is
auto. tuning type. Please follow the maintenance manual to adjust it).
3) If there is anything between the light transmitter(LED) and light receiver(PT) of the WAIT sensor,
that interrupts the WAIT sensor such as wiring, please remove it or make it not to interrupt the sensor.
3 The PWB was staying on the position where WAIT sensor detected the PWB when the error
occurred (the PWB got to the right waiting position then the error occurred).
There is a possibility that the IN sensor detected something if the IN sensor does not get OFF while a
PWB is being conveyed properly. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of IN sensor in the
'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor.
2)If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume control
knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came off the connector part, that a contact pin of the connector part is broken, that wiring
got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any of them
are broken, you need to replace them with new ones.
  4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650223 PWB Conveying Error: PWB conveying error of Input buffer. The process is forcibly terminated.
Please remove on the conveying route
传送基板错误 :|入口缓冲区搬入基板出错,被强行停止。 |请取下基板。
[Cause]
IN sensor detected the next PWB while a PWB is waiting at the Input buffer. The IN sensor is not
supposed to be ON since a PWB request signal was not sent to a machine in the upper part of the line.
Usually, the error occurs when a machine in the upper part of the line outlets a PWB but the PWB
overruns, and the IN sensor detects the PWB.
[Treatment]
1 When a machine in the upper part of the line had outlet a PWB and the IN sensor had detected
the PWB when the error occurred.
1) If it is possible to change the stop position on the machine in the upper part of the line, please
make a modification not to make a PWB overrun to get detected by the IN sensor.
2) If it is not possible to change the stop position on the machine in the upper part of the line, please
move the IN sensor to the inner side of the machine so that a PWB will not get detected by the sensor
even if the board overruns.
2 The PWB had not been detected by the IN sensor when the error occurred (the PWB got to the
right position on the machine in the upper part of the line, and then the error occurred).
There is a possibility that the IN sensor is detecting something else if the IN sensor does not get OFF
even if the machine in the upper part of the line is conveying the PWB properly. Please select
[Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of IN sensor in the 'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor.
2) A If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came out of the connector part, that a contact pin of the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650224 PWB Conveying Error : PWB conveying time out error of Input buffer. The process is forcibly
terminated. Please remove on the conveying route
传送基板错误 :|入口缓冲区搬入基板超过时间。
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN and WAIT sensors when the error
occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB overran the WAIT station and got conveyed to the center station when the error
occurred.
The WAIT sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
WAIT sensor in the 'Status' frame.
1) There is a possibility that the WAIT sensor is broken. It could be that the wiring came out of the
connector part, that a contact pin of the connector part is broken, that wiring got cut off, or that sensor
itself is broken. Please examine the wiring and the connector. If any of them are broken, you need to
replace them with the new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650225 PWB Conveying Error :| Shutter time out error of IN buffer.”
传送基板错误 :|入口快门超时。
E650226 PWB Conveying Error :| IN buffer-Center buffer PWB movement IN sensor ON detection error. |
Please remove it.”
传送基板错误 :|基板在入口缓冲区~中心缓冲区移动时,发现入口传感器ON|请取下基
板。
E650227 PWB Conveying Error :| Timeout in detecting IN sensor's turning OFF.”
传送基板错误 :|口传感器OFF超时。
E650232 PWB Conveying Error :| STOP sensor OFF detection time out error.”
传送基板错误 :|STOP传感OFF超时。
E650233 PWB Conveying Error :| C.OUT sensor OFF detection time out error.”
传送基板错误 :|C.OUT传感器OFF超时。
E650234 PWB Conveying Error : PWB conveying time out error of the center station. The process is forcibly
terminated. Please remove on the conveying route
传送基板错误 :|基板从入口区到中心区移动超过时间。
[Cause]
When inletting a PWB from the Input buffer to the center station, STOP sensor did not get ON even
though a certain amount of time has passed since the WAIT sensor of the Input buffer got OFF.
Usually, this error occurs when a PWB can not go through the INPUT buffer for some reason.
[Treatment]
1 If the PWB was NOT on the position where it is detected by WAIT and STOP sensors when
the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The