JUKI贴片机错误代码.pdf - 第67页
E301038 “ MTS cannot move because of cover opening ” “ 主机盖被打开时, MTS 不能工作 。 ” [Cause] Failed to draw the MTS tray out since t he cover of the machine was open. [Treatment] Please close the cover. E301039 “ The door of MTS…
The laser detection height of nozzle, that was automatically learned, was too high. A nozzle which is
shorter by over 1mm than a standard nozzle was detected. The nozzle length might be too short.
[Treatment]
Please check the nozzle length. [Cause]
E301029 “Vacuum is not ON.”
“没有起动真空器。”
E301032 “MTC is in the supply state”
“MTC 补充状态。”
[Cause]
MTC can not be controlled since it is in the Supply (component change) state.
[Treatment]
Please make MTC a normal status.
E301033 “Password is different from a predetermined one.”
“密码不一致。”
W301034 “The Height of nozzle exceeds a regulated value.%7.4lf mm”
“吸嘴高度超过规定值。%7.4lf mm”
E301035 “MTS is disable”
“不能使用 MTS。”
[Cause]
MTS can not be controlled since it is non-use device (it is set to “not use” in the Use unit in Machine
Setup)
[Treatment]
Please set the MTS to “use” in the Use unit in Machine Setup.
E301036 “MTS power off”
“没有打开 MTS 电源。”
[Cause]
Failed to draw the MTS tray out since the MTS was not ON.
[Treatment]
Please turn on the power supply of MTS.
E301037 “MTS offline”
“MTS 处于脱机状态。”
[Cause]
Failed to draw the MTS tray out since the MTS was not online.
[Treatment]
Please make MTS online.
E301038 “MTS cannot move because of cover opening”
“主机盖被打开时,MTS 不能工作。”
[Cause]
Failed to draw the MTS tray out since the cover of the machine was open.
[Treatment]
Please close the cover.
E301039 “The door of MTS opens”
“MTS 机箱门被打开。”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E301040 “There is no specified stacker with the tray steps number”
“指定阶层托盘存储箱不存在。”
[Cause]
Failed to draw the MTS tray out since there was no stacker which has the specified number of trays.
[Treatment]
Please set the stacker with specified number of trays.
E301041 “Because the IC collection belt is assembled to a rear side, |MTS cannot select.”
“因 IC 回收器安装在后侧,|不能选择 MTS。”
E301042 “Because MTS is selected, the IC conveyor belt is not assembled to a rear side”
“因 MTS 已被选定。|不能把 IC 回收器安装在后侧。”
[Cause]
When MTS was set to use, IC conveyor belt is not available on the rear side.
[Treatment]
You need to disable MTS or install the IC Collection belt on the front side to use.
E301043 “Starting Parameter Error.”
“起动参数错误。”
E301044 “Nozzle length is too long. Please check out the nozzle”
“吸嘴过长。|请检查吸嘴。”
[Cause]
The laser detection height of nozzle, that was automatically learned, was too low. A nozzle which is
longer by over 1mm than a standard nozzle was detected. The nozzle length might be too long.
[Treatment]
Please check the nozzle length.
E301045 “Vacuum Calibration can be set only for small-diameter nozzles.|(Settable range 1 - %d)”
“真空校准只对应小口径吸嘴。|(设置范围:1 - %d)”
E301046 “Only nozzle No. has been input. | Please specify nozzle types”
“只输入了吸嘴号。|请输入吸嘴种类。”
[Cause]
When you entered nozzle No. only, ATC nozzle allocation is not available.
[Treatment]
Please enter nozzle types.
E301047 “An error occurred while taking nozzles off. The process is discontinued”
“因取下吸嘴发生错误。|停止处理。”
[Cause]
This error occurs when the machine determines that a nozzle is still on the head despite that the
nozzle removal process took place.
[Treatment]
If the nozzle is not on the head, the laser might be too dirty to work properly. Please clean the laser.
Also, please check and see if the slide plate can slide properly or the sensor works properly with
Manual control. If the slide plate or the sensor does not work well, something might be broken. Please
take a note of the error No. and contact our technical service dept. for information.
E301048 “Vacuum Calibration unit position can not be measured”
“不能测量真空校准单元位置。”
[Cause]
The ATC which is set on the Vacuum Calibration unit can not be measured.
[Treatment]
When you need to measure the ATC, please UN-allocate then measure it.
E301049 “An error occurred while installing nozzles. | [Error occurs] %d| [Error No.] %d| [Error info] %d”
“安装吸嘴发生错误。|| [错误发生] %5d| [错误 No.] %5d| [错误详细] %5d||%s”
[Cause]
An error occurred while installing a nozzle when a nozzle change.
1): A code which tells where the error occurred.
2): Error code
3): Error details code
[Treatment]
Please take a note of the error No., and contact our technical service dept. for information.
E301050 “In 2030, Vacuum Calibration can be set for only R1 through R4”
“在 2030, 真空校准只对应从 R1 到 R4.”
[Cause]