E301045 “ Vacuum Calibration can be set onl y for small-diameter nozzl es.| (Settable range 1 - %d) ” “ 真空校准只对应小口径吸嘴。 |( 设置范围: 1 - %d) ” E301046 “ Only nozzle No. has been i nput. | Please specify nozzle types ” “ 只输入了吸嘴…
E301038 “MTS cannot move because of cover opening”
“主机盖被打开时,MTS 不能工作。”
[Cause]
Failed to draw the MTS tray out since the cover of the machine was open.
[Treatment]
Please close the cover.
E301039 “The door of MTS opens”
“MTS 机箱门被打开。”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E301040 “There is no specified stacker with the tray steps number”
“指定阶层托盘存储箱不存在。”
[Cause]
Failed to draw the MTS tray out since there was no stacker which has the specified number of trays.
[Treatment]
Please set the stacker with specified number of trays.
E301041 “Because the IC collection belt is assembled to a rear side, |MTS cannot select.”
“因 IC 回收器安装在后侧,|不能选择 MTS。”
E301042 “Because MTS is selected, the IC conveyor belt is not assembled to a rear side”
“因 MTS 已被选定。|不能把 IC 回收器安装在后侧。”
[Cause]
When MTS was set to use, IC conveyor belt is not available on the rear side.
[Treatment]
You need to disable MTS or install the IC Collection belt on the front side to use.
E301043 “Starting Parameter Error.”
“起动参数错误。”
E301044 “Nozzle length is too long. Please check out the nozzle”
“吸嘴过长。|请检查吸嘴。”
[Cause]
The laser detection height of nozzle, that was automatically learned, was too low. A nozzle which is
longer by over 1mm than a standard nozzle was detected. The nozzle length might be too long.
[Treatment]
Please check the nozzle length.
E301045 “Vacuum Calibration can be set only for small-diameter nozzles.|(Settable range 1 - %d)”
“真空校准只对应小口径吸嘴。|(设置范围:1 - %d)”
E301046 “Only nozzle No. has been input. | Please specify nozzle types”
“只输入了吸嘴号。|请输入吸嘴种类。”
[Cause]
When you entered nozzle No. only, ATC nozzle allocation is not available.
[Treatment]
Please enter nozzle types.
E301047 “An error occurred while taking nozzles off. The process is discontinued”
“因取下吸嘴发生错误。|停止处理。”
[Cause]
This error occurs when the machine determines that a nozzle is still on the head despite that the
nozzle removal process took place.
[Treatment]
If the nozzle is not on the head, the laser might be too dirty to work properly. Please clean the laser.
Also, please check and see if the slide plate can slide properly or the sensor works properly with
Manual control. If the slide plate or the sensor does not work well, something might be broken. Please
take a note of the error No. and contact our technical service dept. for information.
E301048 “Vacuum Calibration unit position can not be measured”
“不能测量真空校准单元位置。”
[Cause]
The ATC which is set on the Vacuum Calibration unit can not be measured.
[Treatment]
When you need to measure the ATC, please UN-allocate then measure it.
E301049 “An error occurred while installing nozzles. | [Error occurs] %d| [Error No.] %d| [Error info] %d”
“安装吸嘴发生错误。|| [错误发生] %5d| [错误 No.] %5d| [错误详细] %5d||%s”
[Cause]
An error occurred while installing a nozzle when a nozzle change.
1): A code which tells where the error occurred.
2): Error code
3): Error details code
[Treatment]
Please take a note of the error No., and contact our technical service dept. for information.
E301050 “In 2030, Vacuum Calibration can be set for only R1 through R4”
“在 2030, 真空校准只对应从 R1 到 R4.”
[Cause]
In 2030, Vacuum Calibration unit can be set only for R1 through R4.
[Treatment]
Please set to ATC of R1 through R4.
E301051 “Vacuum Calibration can be et only for small-diameter nozzles. | (Settable range : 1 - %d)”
“对于该 ATC 不能设置真空校准。”
[Cause]
The Vacuum Calibration unit can not be set other ATC than the ATC of small nozzles.
|The maximum settable ATC number
[Treatment]
Please set the unit for the ATC of small nozzles.
E301052 “Any heads have not been specified”
“没有指定 Head。”
[Cause]
You did not specify a head to be measured.
[Treatment]
Please specify a head to measure.
E301053 “The Changer table can not be installed on the rear side since MTC/MTS have been selected”
“因 MTC/MTS 已被选择,不能把送料器台车安装在后侧。”
[Cause]
You can not use the changer table on the rear side when MTC or MTS is set to use.
[Treatment]
Please disable MTC or MTS when you use the changer table on the rear side.
E301054 “MTC/MTS can not be connected to 2000 series machines at the same time”
不能同时连接 MTC 和 MTS。”
[Cause]
MTC and MTS can not be set at the same time.
[Treatment]
Please disable one of them.
E301055 “An error on axes occurred”
“轴发生错误。”
[Cause]
An error occurred while axes were traveling.
[Treatment]
Please contact our technical service dept. for information.
E301056 “An error on XY axes occurred”