JUKI贴片机错误代码.pdf - 第325页
1) The cause might be the abnormality of the air plumbing to PW B detector. It could be that the speed controller was wrung to its li mit, that the air plumbing came o ff, or that the air plumbing is w rong. Please exami…
“基板传送错误 :|因发现检查气缸干涉基板, |气缸不能上升。| 请取下基板。”
[Cause]
Failed to lift up the cylinder that had been coming down since a PWB was detected at the cylinder
lifting-up position.
打算要使检查汽缸上升, 但是,因为在汽缸上升动作位置上检测出基板,所以没能进行上
升动作。
[Treatment]
Please take the PWB off the conveyor.
请除去传送轨道上的基板。
E650010 “Conveying device error: | Due to the abnormality of the check cylinder sensor, | cylinder can not
come up. | Please re-start the machine and check again”
“基板传送错误: |因检测到基板气缸传感器错误,气缸不能上升。重新启动后,再检查。”
[Cause]
The sensor of the check cylinder did not get ON within a certain time although you tried to run the
check cylinder.
虽进行检查气缸操作, 但检查气缸传感器不能在规定时间内开启。
[Treatment]
Select [Manual Control] from the menu bar, and choose [Control(C)] [Conveyor(C)] and [Movable
station control(A)]. Select “PWB detect pin” from the “Control Item” and [PWB detect pin(A)] from
[Control item] frame to enable or disable ON/OFF. The treatments to take depends on the result you
get from the action above.
1 Cylinder works fine.
1.1 The status of 'PWB check sensor' in the 'status' displaying frame gets ON/OFF.
The cause might be that the speed controller of the PWB detector was wrung too much. Please release
the speed controller of the PWB detector.
1.2 The status of 'PWB check sensor' in the 'status' displaying frame does not get ON/OFF.
1) The cause might be that PWB check sensor was adjusted to out of the operation range of the
cylinder. Please re-adjust the sensor to where it gets ON/OFF.
2) If the treatment1 above does not work, there is a possibility that the PWB check sensor is broken.
It could be that the wiring came out of the connector part, that a contact pin of the connector part is
broken, that wiring got cut off, or that sensor itself is broken (If LED of the PWB check sensor gets
ON/OFF but the status of 'PWB check sensor' in the 'status' displaying frame does not get ON/OFF,
signal line of the PWB check sensor may be either abnormal or cut off, or the connector part does not
work well).
Please examine the wiring and connector part. If any of them are broken, you need to replace them
with new ones.
3) If the treatment2 does not even work, PCB is broken or the wiring between the PCBs is bad.
2 Cylinder does not work.
1) The cause might be the abnormality of the air plumbing to PWB detector. It could be that the speed
controller was wrung to its limit, that the air plumbing came off, or that the air plumbing is wrong.
Please examine the air plumbing and see if it is connected properly.
2) The PWB detector itself may be broken. Please stop the air supply on the machine and see if the
cylinder shaft works properly or not manually. If the shaft does not work smoothly, you need to
replace it with a new one.
3) The driving solenoid valve may be broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector is broken, that wiring got cut off, or that the solenoid valve
itself is broken. Please examine the wiring and connector part. If anything wrong with them, you need
to replace them with new ones.
4) If none of the treatments above works, PCB is broken or the wiring between the PCBs is bad.
E650100 “Conveying error : An asynchronous, abnormal event occurred while PWB conveying. The process
is forcibly terminated”
“基板传送错误: |传送基板时,发生异步现象。”
[Cause]
The conveying process got forcibly terminated since a critical asynchronous event(Emergency STOP,
etc.) occurred during the PWB conveying.
[Treatment]
Please remove the PWB(s) on the conveyor and perform Home returning.
W650203 “PWB Conveying Error: There is no PWB objective to be conveyed”
“传送基板错误 :|没有发现传送对象基板。”
[Cause]
A request of PWB conveying was issued while there was no PWB on the conveyor center station.
This error occurs only at the PWB conveying process(letting PWB come out of the conveyor) that
does not affect on a production.
[Treatment]
Please see if there is any PWB on the conveyor, then execute a process of letting PWB come out of
the conveyor.
W650204 “PWB Clamp Error : There is no PWB objective to be unlocked”
“固定基板错误 :|解除固定时,没有发现对象基板。”
[Cause]
A request of unlocking a PWB was issued while there was no PWB clamped on the conveyor center
station. This error occurs only at the PWB conveying process(unlocking PWB) that does not affect on
a production.
[Treatment]
Please see if there is any PWB locked(clamped), then execute a process of unlocking the PWB.
I650205 “Conveying Error : Please carry out the PWB on the Exit side station prior to the one on the Entrance
side station”
“传送基板错误 :|请先搬出出口缓冲区的基板。”
[Cause]
On the KE2030, a request of individual outlet conveying for the Entrance station was issued while
there was a PWB on the conveyor center Entrance/Exit station. This error occurs only at the PWB
conveying process(outlet conveying) that does not affect on a production.
[Treatment]
Please have a PWB on the center Exit station go first or have PWBs on both station go together.
E650208 “PWB Conveying Error :| Central motor Stop Check error.”
“传送基板错误 :|检查中心马达停止错误。”
[原因]
中心马达停止控制异常。作为原因,能考虑轴控制器基板的异常状态。
[解决]
关闭设备,关掉电源之后,请重新启动。
当以上的处理没有解决问题时,能考虑为轴控制基板的故障。
请与代理店或本公司技朮服务部取得联系。
W650209 “PWB Conveying Error : A PWB has been detected on the conveying route. Please remove it”
“传送基板错误 :|传送轨道上发现基板。|请取下基板。”
[Cause]
While conveying PWBs, an unexpected PWB was detected at the several buffers on the conveyor.
[Treatment]
Please remove the PWB from the conveyor.
W650211 “PWB Conveying Error : A PWB has been detected on the center station. Please remove it”
“传送基板错误 :|C.OUT传感器发现基板。|请移走出口缓冲区的基板。”
[Cause]
While conveying PWBs, an unexpected PWB was detected at the center station on the conveyor.
[Treatment]
Please remove the PWB from the center station.
W650212 “PWB Conveying Error: A PWB has been detected on the center station on the Entrance side.
Please remove it”
“传送基板错误 :|在入口侧中心缓冲区,发现基板。|请取下基板。”
[Cause]
While conveying PWBs on the KE2030, an unexpected PWB was detected at the center Entrance
station on the conveyor.
[Treatment]