that the wiring came out of the connector part, that a contact pin in t he connector part is broken, that wiring got cut off, or t hat sensor itself is broken. Please exa mine the wiring and the connector. If any of them…

100%1 / 464
connector part, that a contact pin in the connector part is broken, that the wiring got cut off, or that the
sensor itself is broken. Please examine the wiring and the connector. If any of them are broken, you
need to replace them with new ones.
2) If the treatment1 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650325 Idle PWB Conveying Error :| Shutter time out error of IN buffer. | Please remove it.”
传送基板(通过)错误 :|入口快门超时。
E650326 Idle PWB Conveying Error :| IN buffer-center buffer PWB movement IN sensor ON detection error.
| Please remove it.”
传送基板(通过)错误 :|基板从入口缓冲区到中心缓冲区移动中,入口传感器打开错误。
E650332 Idle PWB Conveying Error :| STOP sensor OFF detection time out error. | Please remove it.”
传送基板(通过)错误 :|等待传感器关闭超时。
E650333 Idle PWB Conveying Error :| C.OUT sensor OFF detection time out error. | Please remove it.”
传送基板(通过)错误 :|C.OUT传感器关闭超时。
E650334 Idle PWB Conveying Error : PWB conveying time out error of the center station. The process is
forcibly terminated. Please remove on the conveying route
传送基板(通过)错误 :|从入口缓冲区到中心缓冲区的基板移动超时。
[Cause]
When insetting a PWB from the Input buffer to the center station, STOP sensor did not get ON even
though a certain amount of time has passed since the WAIT sensor of the Input buffer got OFF.
Usually, this error occurs when a PWB can not go through the INPUT buffer for some reason.
[Treatment]
1 The PWB was on the position where it is NOT detected by WAIT and STOP sensors when the
error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB overran the STOP sensor when the error occurred.
The STOP sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of the
STOP sensor in the 'Status' frame.
1) The sensitivity of the STOP sensor may be too low. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650335 Idle PWB Conveying Error :| PWB conveying error of the center buffer. | Please remove it.”
传送基板(通过)错误 :|在中心缓冲区发生错误。
E650342 Idle PWB Conveying Error : PWB conveying error of the center station on the Entrance side. The
process is forcibly terminated. Please remove on the conveying route
传送基板(通过)错误 :|STOP1传感器OFF超时。
[Cause]
This error occurs if the STOP sensor on the center station on the Entrance side got OFF then ON
again, but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Entrance side to the center station on the Exit side.
[Treatment]
1 The PWB was on the position where it is detected by the STOP sensor on the center station on
the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PW width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by the STOP sensor on the center
station on the Entrance side when the error occurred.
If the STOP sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
STOP sensor on the center station on the Entrance side in the 'Status' frame.
1) The sensitivity of the STOP sensor may be too high. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650343 Idle PWB Conveying Error : PWB conveying error of the center station on the Entrance side. The
process is forcibly terminated. Please remove on the conveying route
传送基板(通过)错误 :|C.OUT1传感器OFF超时。
[Cause]
This error occurs if the C-OUT sensor on the center station on the Entrance side got OFF then ON
again, but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Entrance side to the center station on the Exit side.
[Treatment]
1 The PWB was on the position where it is detected by the STOP sensor on the center station on
the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PW width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by the C-OUT sensor on the center
station on the Entrance side when the error occurred.
If the C-OUT sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
C-OUT sensor on the center station on the Entrance side in the 'Status' frame.
1) The sensitivity of the C-OUT sensor may be too high. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the C-OUT sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650344 Idle PWB Conveying Error : PWB conveying time out error of the center station on the Entrance
side. The process is forcibly terminated. Please remove on the conveying route
传送基板(通过)错误 :|从入口缓冲区到入口侧中心缓冲区的基板移动超时。
[Cause]
This error occurred because the STOP sensor on the center station on the Exit side did not get ON
even though a certain amount of time has passed since the WAIT sensor on the center station on the
Entrance side got OFF when conveying a PWB on the center station on the Entrance side to the center
station on the Exit side. Usually, this error occurs when a PWB can not go through the INPUT buffer
for some reason.
[Treatment]
1 If the PWB was on the position where it is NOT detected by WAIT sensor or the STOP sensor