An error occurred during the m easurement(SWEEP) by laser. 1): Error code 2): A communication error occurred. 3): An axis error occurred. [Treatment] Please contact our technical serv ice dept. for information. E906105 “…
[Cause]
Failed to pick up the Calibration jig for VCS. An out-of-component error occurred in the Laser
recognition of the Calibration jig for VCS.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration station.
E906101 “Error has occurred when detecting height of measuring plane of laser | code:%ld”
“检测激光测量高度发生错误。|代码: %ld”
[Cause]
An error occurred when measuring the height by laser.
1: Error code
2: The shadow does not get clear when lifting Z axis up.
3: There is not shadow when lowering Z axis down.
4: After detecting a shadow once, Z axis was lifted up but thshadow does not get clear.
5: A communication error occurred.
6: An axis error occurred.
[Treatment]
Something may be wrong with the Laser alignment. Please check the Laser alignment.
E906102 “Error has occurred during laser measurement(ONCE) | code:%ld”
“设置激光参数发生错误。|代码: %ld”
[Cause]
An abnormal matter happened in the Parameter setting of Laser.
1): Error code.
2): A communication error occurred.
[Treatment]
Please contact our technical service dept. for information.
E906103 “Error has occurred during laser measurement(ONCE) | code:%ld”
“激光测量(ONCE)发生错误。|代码: %ld”
[Cause]
An error occurred during the measurement (ONCE) by laser.
1): Error code.
2): A communication error.
[Treatment]
Please contact our technical service dept. for information.
E906104 “Error has occurred during laser measurement (SWEEP) | code:%ld”
“激光测量(SWEEP)发生错误。|代码: %ld “
[Cause]
An error occurred during the measurement(SWEEP) by laser.
1): Error code
2): A communication error occurred.
3): An axis error occurred.
[Treatment]
Please contact our technical service dept. for information.
E906105 “Error has occurred during the component presence check | code: %ld”
“检查组件存在状况发生错误。|代码: %ld”
[Cause]
A communication error occurred during the component presence check.
[Treatment]
Please contact our technical service dept. for information.
E906201 “Error has occurred during acknowledgment of mark”
“标记识别错误。”
[Cause]
An error occurred during the Mark recognition by a vision unit.
[Treatment]
Please check and see if the recognition requirements are correct and if the focus and tone of the
camera are well adjusted. If this error occurs even after checking the requirements and adjustment,
then something might be wrong with vision unit. Please check the vision unit.
E906301 “Error has occurred on axis | code:%ld”
“轴发生错误。|代码: %ld”
[Cause]
An error occurred while an axis was traveling.
[Treatment]
W906401 “1.Vacuum generating power of ejector is beyond regular level.|Ejectors need to be changed.|2.Air is
leaking from the air pipe path.|Air paths need to be inspected.|3.Main air pressure is too low.|Check
the pressure.”
“1.真空发生器的吸引力偏高。|需要更换发生器。|2.发生空气管道漏气。|需要检查空气管
道。|3.发生气压偏低。|需要检查气压。”
W906402 “1.Vacuum generating power of ejector is low.|Ejectors need to be changed.|2.Air is leaking from
the air pipe path.|Air paths need to be inspected.”
“1.真空发生器的吸引力偏低。|需要更换排出器。|2.发生空气管道漏气。|需要检查空气管
道。”
W906403 “1.Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
“1.吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。”
W906404 “1.Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”
“1.因VAC电磁阀故障,发生动作迟钝现象。|需要更换VAC电磁阀。”
W906405 “1.The head side pressure sensor is trouble. |Pressure sensor needs to be changed.|2.VAC
electromagnetic valve is trouble.|VAC electromagnetic valve needs to be changed.”
“1.Head侧的压力传感器发生故障。|需要更换压力传感器。|2.VAC电磁阀故障。|需要更换
电磁阀”
W906406 “1.The V.CAL side pressure sensor is trouble. |Pressure sensor needs to be changed.|2.The vacuum
calibration unit may be in wrong position.”
“1.真空校准侧的压力传感器发生故障。|需要更换压力传感器。|2.真空校准单元的位置是否
正确。”
W906407 “1.Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”
“1.因VAC电磁阀故障,发生动作迟钝现象。|需要更换VAC电磁阀。”
W906408 “1.The vacuum exhaust cannot be smoothly done by stuff in the nozzle axis of ejector. |Ejector
needs to be changed.”
“1.因真空发生器轴部的堵赛,真空排气不平稳。|需要更换空气过滤器。”
W906409 “1.Latency of movement occurred due to the Blow electromagnetic valve trouble.|Blow
electromagnetic valve needs to be changed.”
“1.吹气电磁阀发生故障,发生动作迟钝现象。|需要更换吹气电磁阀。”
Q907001 “Reset I/O?”
“是否重设I/O ?”
[Cause]
You are asked if to set each I/O in the safety direction.
[Treatment]
“YES” button will sets I/O in the safety direction. “NO” button will not.
Q907002 “Exit self calibration. Set value is saved?”
“退出自动校准。|是否保存设置?”
[Cause]
This message gets displayed when you choose “Exit self calibration” . You are asked if you want to
save the parameter which was set in the Self Calibration setting.
[Treatment]
“YES” button will save the set value. “NO” button will not save it. “Cancel” button will cancel the