JUKI贴片机错误代码.pdf - 第49页
[Cause] This error occurs when trying to teach a feeder pickup coordina te on the right feeder bank to t he machine by using a device on the left side. [Treatment] Please use a device on the right side when t eaching a f…
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E290000 “The origin point return is non-completion. | Please execute the teaching after the origin point
returns”
“没有执行原点返回。|请执行原点返回后,进行示教。”
[Cause]
Home returning has not been complete yet.
[Treatment]
Please press ORIGIN button to perform the Home returning, then try the teaching again.
E290001 “The OCC device is set in unused by the setup. | The teaching in the OCC device cannot be done”
“在设置中,OCC 装置没有被选用。”
[Cause]
OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If OCC is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot be
executed.
E290002 “The bad mark reader device is set in unused by the setup. | The teaching in the bad mark reader
device cannot be done”
”在设置中,识别坏板标记装置没有被选用。”
[Cause]
The Bad mark reader device is set to “not use” in the Use unit in Setup.
[Treatment]
If the Bad mark reader device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E290003 “The HMS device is set in unused by the setup. | The teaching in the HMS device cannot be done”
“在设置中,HMS 装置没有被选用。”
[Cause]
The HMS device is set to “not use” in the Use unit in Setup.
[Treatment]
If the HMS device is available, please set it to “use” in the Use unit in Setup. If not, this procedure
cannot be executed.
E290004 “The pick up point in the right feeder bank cannot be the teaching with a left device. Please use a
right device”
“不能以左侧装置示教右侧送料器台架上的吸着坐标。请选用右侧装置。”
[Cause]
This error occurs when trying to teach a feeder pickup coordinate on the right feeder bank to the
machine by using a device on the left side.
[Treatment]
Please use a device on the right side when teaching a feeder pickup coordinate on the right feeder
bank to the machine.
E290005 “The pick up point in the left feeder bank cannot be the teaching with a right device. Please use a left
device”
“不能以右侧装置示教左侧送料器台架上的吸着坐标。请选用左侧装置。”
[Cause]
This error occurs when trying to teach a feeder pickup coordinate on the left feeder bank to the
machine by using a device on the right side.
[Treatment]
Please use a device on the left side when teaching a feeder pickup coordinate on the left feeder bank
to the machine.
E290006 “The memory access error occurred”
“访问内存出错。”
[Cause]
Failed to write the data in or to read the data from the shared memory.
[Treatment]
Please reboot the machine. If the error occurs even after rebooting, please contact our technical
service dept. for information.
E290007 “The Head device is set in unused by the setup”
“在设置中,Head 装置没有被选用。”
[Cause]
The specified head is set to “not use” in the Use unit in Setup.
[Treatment]
If the specified head is available, please set it to “use” in the Use unit in Setup. If not, this procedure
cannot be executed.
E290008 “HW error. Execution is aborted”
“因硬件出错,停止运行。”
[Cause]
A requested action to an axis or other hardware got an error. There may be a possibility of alarm
occurrence, servo free, Emergency STOP, etc.
[Treatment]
Please try Servo Free unlocking, Home returning, etc.
E290009 “Can not mark-teaching by R OCC. L OCC use,please.”
“右侧 OCC 不能示教标记,请使用左侧 OCC。”
E290010 “DTS cannot be executed.”
“不能运行 DTS。”
E290011 “DTS is not initialized.”
“DTS 没有初始化。”
E290012 “DTS safety cover opens.”
“DTS 安全盖被打开。
E290013 “DTS is in the state of supply.”
“DTS 处于补充状态。”
E290014 “DTS failed in drawing out the tray.”
“DTS 取出托盘失败。”
E290015 “DTS device is set in unused by the setup.”
“在设置中,DTS 装置没有被选用。”
E290016 “It is not possible to move to specified position with this device.”
“这个设备不能移到指定坐标上。”
E290017 “Check sum error of template data. Please teaching try again.”
“检查模板数据合计出错。请再次示教修改。”
E290020 “There is no power supply of MTS.”
“没有打开 MTS 电源。”
E290021 “MTS is stopping the emergency.”
“MTS 被紧急停止。”
E290022 “MTS is not initialized.”
“没有初始化 MTS。”
E290023 “MTS is in the state of off-line.”
“没有连接 MTS。”
E290024 “MTS stacker cover opens.”
“MTS 托盘存储箱盖被打开。”
E290025 “MTS is in the state of supply.”
“MTS 处于补充状态。”