JUKI贴片机错误代码.pdf - 第376页

‧If the error occurs when the c ontact is good, there i s a poss ibility that the Component Veri fication unit is broken. Ple ase contact our technical service dept. for information. E690024 “ Somethi ng is wrong with th…

100%1 / 464
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690021 The measured voltage does not get stable. | Please check the probe status
读取的电压不稳定。|请检查探针状态
[Cause]
The voltage gotten from the tester does not get stable.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690022 Something is wrong with the measured resistance
测定的电阻有些异常。
[Cause]
The resistance gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690023 Something is wrong with the measured volume
测定的电容有些异常。
[Cause]
The condenser capacity gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690024 Something is wrong with the measured voltage
测定的电压有些异常。
[Cause]
The voltage gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690025 Something is wrong with the measured resistance(unit)
测定的电阻(单位)有些异常。
[Cause]
The unit for the resistance gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690026 Something is wrong with the measured volume(unit)
测定的电容(单位)有些异常。
[Cause]
The unit for the condenser capacity gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690027 Something is wrong with the measured voltage(unit)
测定的电压(单位)有些异常。
[Cause]
The unit for the voltage gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690028 Resistance can no be measured. | Please check if probe shuts down properly
不能测定电阻。|请检查探针是否已关闭。
[Cause]
The tester overflowed data when measuring the resistance.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690029 Volume can not be measured. | Please check if probe shuts down properly
不能测定电容。|请检查探针是否已关闭。
[Cause]
The tester overflowed data when measuring the condenser capacity.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification