I904012 “ It failed to upgrade .” “ 版本升级失败。 ” I904013 “ The program data on I/O CPU has successfully been deleted .” “ I/O CPU 程序数据删除完毕。 ” I904014 “ Failed to delete the program data on I/O CPU .” “ 删除 I/O CPU 程序数据失败。 ” …

I903011 “Remove the nozzle from %s.”
“请取下%s上的吸嘴。”
I903012 “Set nozzle on %s.”
“请给%s安装吸嘴。”
I903013 “Remove the PWB on Conveyor.”
“请取下传送轨道上的基板。”
I903014 “The direction of the installation of the gauge block is different. |Put and substitute it. “
“测量器的安装方向不同。|请调换方向。”
I903015 “Remove the Gauge Block from R1.”
“请取下测量器。”
I903016 “Reboot the system to enable parameters you set. “
“为了有效设定参数,请再启动系统。”
I904001 “Return to home.|Remove jig from CAL block.”
“进行返回原点。|请取下校准块上的模具。”
I904002 “Return to home.(Z axis)”
“进行Z轴返回原点。”
I904003 “Select 'OK' to recognizes 1'st mark of CAL block.|(will return to home first).”
“选择确定按钮,开始运行原点返回后,识别校准块第一标记。”
I904004 “Return to home.(Backup table)”
“进行支撑台返回原点。”
I904005 “Return to home.(AWC)”
“进行AWC返回原点。”
I904006 “Return to home.”
“进行原点返回”
I904121 “File has been read.”
I904122 “File reading process has been interrupted.”
I904123 “EEPROM has been clear.”
I904124 “EEPROM clear process has been interrupted.”
I904011 “It finished to upgrade.”
“版本升级成功。”
I904012 “It failed to upgrade.”
“版本升级失败。”
I904013 “The program data on I/O CPU has successfully been deleted.”
“I/O CPU程序数据删除完毕。”
I904014 “Failed to delete the program data on I/O CPU.”
“删除I/O CPU程序数据失败。”
I904015 “The program data on B/F CPU has successfully been deleted.”
“B/F CPU程序数据删除完毕。”
I904016 “Failed to delete the program data on B/F CPU.”
“删除B/F CPU程序数据失败。”
I904017 “Gauge Block is set on R1.|R1 moves to jig installing position by selecting 'OK'.”
“测量器被安装在R1。|向取下它的位置移动。”
I904030 “Juki vision system is %s.”
“图像处理装置的版本是%s。”
I904040 “Succeeded in the format of the flash memory of Juki vision system. “
“图像处理装置闪存卡的格式化结束。”
I904041 “Failed in the format of the flash memory of Juki vision system. “
“图像处理装置闪存卡的格式化失败。”
E906001 “Memory allocation error”
“内存分配错误。”
[Cause]
The working space can not be saved.
[Treatment]
Please increase some more memory available to save the working space.
E906002 “Shared memory open error”
“打开共享内存错误。”
[Cause]
The shared memory could not be open.
[Treatment]
Please shut down the your machine and re-start it.
E906011 “Measurement result exceeds limit value. Check the MS parameter”
“测量结果超过界限。|请检查一下MS参数。”
[Cause]
An assemblage position offset of a measured head exceeded the limit value. The limit is: -9.9999
through 9.9999
[Treatment]
System error
Please check the MS parameter.
E906021 “Return to home has not yet been completed”
“尚未结束返回原点。”
[Cause]
The axis has not yet been returned to home.
[Treatment]
Please perform the Return to home with ORIGIN switch.
E906022 “Servo is in the free state”
“伺服处于未使用状态。”
[Cause]
The axis could not move since the servo is not locked.
[Treatment]
Please lock the servo with S-FREE switch.
E906031 “Selected device is not install. Please reselect other device on HOD”
“没有安装被选设备。|请重新选择其它设备。”
[Cause]
You could not go into the teaching mode since the device selected by HOD has not been installed.
[Treatment]
Please reselect the device which is currently installed.
E906041 “There is no installed head”
“不存在可用Head。”
[Cause]
You could not specify a head since there is no head available.
[Treatment]
Please set to “use” in the Use unit setting in Machine Setup.
E906042 “There is no installed VCS”
“不存在可用VCS。”
[Cause]
You could not specify VCS since no VCS has been installed or there is no VCS available.
[Treatment]
Your request is not available on the machine that do not have VCS. If your machine has VCS, please