mode. 1) Please turn off the power supply of you r machine and reboot it. 2) If the treatment1 does not work, please see if the wiring an d connectors in the XMP board are properly connected. 3) If the treatment2 does no…

100%1 / 464
in a Ref. pin hoe on the PWB. Please set the positions of the Ref. pin and the follower pin correctly to
the position of the Ref. hole.
2) An implement or component got caught between the PWB on the center station on the Entrance
side and the center station. Please see if there is anything to obstruct clamping between the PWB and
the center station.
3) The backup pin is pushing up the back side of the PWB on which components are already mounted.
Please change the position of the backup pin to make it touch the PWB.
4) The thickness of PWB was set to significantly thin in the PWB data. Please re-enter the correct
thickness.
2. Backup table on the center station on the Entrance side went up at a high speed, and the
continuous collision sound came out.
1) The encoder on the center station on the Entrance side, that decides a position of PWB may be
broken. It could be that the wiring came off the connector part, that a contact pin in the connector part
is broken, that wiring got cut off, or that the encoder itself is broken. Please examine the wiring and
connector part. If any of them are broken, you need to replace them with new ones.
2) There is a possibility that the screw that holds the encoder and the encoder axis together is loose,
Please examine if the screw is tightened up enough.
3) If the treatments above do not work, PCB is broken or the wiring between the PCBs is bad.
3. The motor made a noise but the backup table on the center station on the Entrance side did not
come up.
There is a possibility that the up-and-down motion system under the backup table that is on the center
station on the Entrance side has a problem. The timing belt, the screw that holds a belt pulley, or the
screw that holds a motor may be loose. Please see if the each part is tightened up enough.
4. The backup table on the center station on the Entrance side did not come up and the motor did
not make any noise.
1) There is a possibility that the stepping motor is broken. It could be that the wiring came off the
connector part, that a contact pin of the connector part is broken, that that wiring got cut off, or that
the motor itself is broken. Please examine the wiring and connector part. If any of them are broken,
you need to replace them with new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650282 Clamp error : Time-out occurred while backup plate of the center station on the Entrance side went
up. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|入口侧中心缓冲区,支撑台上升超时。
[Cause]
The backup plate on the center station on the Entrance side did not get to the aimed clamp height. As
a cause, there is a possibility that the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650283 Clamp error: Time-out occurred while backup plate of the center station on the Entrance side went
down illegally. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|入口侧中心缓冲区,支撑台下降失败。
[Cause]
The backup plate on the center station on the Entrance side did not get down to the aimed clamp
height. This error usually occurs when there happens a mechanical hindrance to make the backup
plate go down.
[Treatment]
1. If the backup table on the center station on the Entrance side was going down when the error
occurred.
There is an implement or some such between the backup table and a frame or mechanism underneath
it. Please examine if there is anything under the backup table.
2. Backup table on the center station on the Entrance side went down at a high speed, and the
continuous collision sound came out.
1) The encoder on the center station on the Entrance side, that decides a position of PWB may be
broken. It could be that the wiring came off the connector part, that a contact pin in the connector part
is broken, that wiring got cut off, or that the encoder itself is broken. Please examine the wiring and
connector part. If any of them are broken, you need to replace them with new ones.
2) There is a possibility that the screw that holds the encoder and the encoder axis on the center
station on the Entrance side together is loose. Please examine if the screw is tightened up enough.
3) If the treatments above do not work, PCB is broken or the wiring between the PCBs is bad.
3. The motor made a noise but the backup table did not come down.
There is a possibility that the up-and-down motion system under the backup table that is on the center
station on the Entrance side has a problem. The timing belt, the screw that holds a belt pulley, or the
screw that holds a motor may be loose. Please see if the each part is tightened up enough.
4. The backup table did not come down and the motor did not make any noise.
1) There is a possibility that the stepping motor is broken. It could be that the wiring came off the
connector part, that a contact pin of the connector part is broken, that wiring got cut off, or that the
motor it self is broken. Please examine the wiring and connector part. If any of them are broken, you
need to replace them with new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650284 Clamp error: Time-out occurred while backup plate of the center station on the Entrance side went
down. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|入口侧中心缓冲区,支撑台下降超时。
[Cause]
The backup plate on the center station on the Entrance side did not get down tow the aimed height. As
a cause, there is a possibility that the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650285 Clamp error : Something is wrong with the backup motor movement of the center station on the
Entrance side. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|入口侧中心缓冲区,支撑台马达运转异常。
[Cause]
The backup plate on the center station on the Entrance side did not get to the aimed clamp height. As
a cause, there is a possibility that the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650286 Clamp error : Hole reference process at the center station on the Entrance side finished illegally.
The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|入口侧中心缓冲区,孔基准动作异常。
[Cause]
The backup plate on the center station on the Entrance side got to the aimed clamp height but the Ref.
pin sensor did not get ON. This error is likely to occur when the Ref. pin did not get in the positioning
hole correctly.
[Treatment]
1 The Ref. pin is not in the positioning hole correctly.
Please set the positions of the Ref. pin and the follower pin on the center station on the Entrance side
correctly to the position of the Ref. hole. If you want to position PWBs with Outer shape Ref., please
make sure that 'Outer shape Ref.' is enabled in the PWB data in the Program Editor.