JUKI贴片机错误代码.pdf - 第130页

“ 轴发生错误。 ” [Cause] Something was wrong with axis movement. [Treatment] Please perform the Home returning. E510005 “ The command error occurred ” “ 发生命令错误。 ” [Cause] An UN-recognizable command was issued. [Treatment] A wr…

100%1 / 464
错误级别低于警告级别。|ATC : 不能设置%s 的错误级别。
I509210 error level is over the Warning level.|The warning level of %s can not be set.”
警告级别高于错误级别。|不能设置%s 的警告级别。
I509211 The warning level is less than the error level.|The error level of %s can not be set.”
错误级别低于警告级别。|不能设置%s 的错误级别。
Q509300 Number of picked components is over the error level.|Number of picked components  %d error
level  %d|Would you like to set the data?
ATC 交换次数超过错误级别。|ATC 交换次数:%d 错误级别:%d|是否设置资料?
Q509301 Number of placed components is over the Number of picked components.|Number of placed
components  %d Number of picked components  %d|Would you like to set the data?
总贴片数超过总吸取数。|总贴片数:%d 总吸取数:%d|是否设置资料?
Q509302 Number of placed components is over the Number of picked components.|Number of placed
components  %d Number of picked components  %d|Would you like to set the data?
交换吸嘴次数超过总吸取数。|交换吸嘴次数:%d 总吸取数:%d|是否设置资料?
E510001 The error occurred by the XY axis
XY 轴发生错误。
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510002 The error occurred by the Z axis
Z 轴发生错误。
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510003 The error occurred by the Theta axis
θ轴发生错误。
[Cause]
Something was wrong with the Theta axis movement.
[Treatment]
Please perform the Home returning.
E510004 The error occurred by the axis
轴发生错误。
[Cause]
Something was wrong with axis movement.
[Treatment]
Please perform the Home returning.
E510005 The command error occurred
发生命令错误。
[Cause]
An UN-recognizable command was issued.
[Treatment]
A wrong version has been installed.
Please install the latest software.
E510006 Failed in the opening of the master schedule
打开主调度程序失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510007 Failed in create of the mail of the scheduler
创建调度程序邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510008 Failed in the opening of the mail of the application-manager
打开程序管理邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510009 Failed in the mail transmission to the application-manager
往程序管理发送邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510010 Failed in the mail check
检查邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510011 Failed in the mail reception
接收邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510012 Failed in the opening of the mail of the production-control
打开生产管理邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510013 Failed in the transmission of the mail to the production-control
往生产管理发送邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510014 Failed in the opening of the command of the Trans-driver
打开传送驱动命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510015 Failed in the transmission of the command to the Trans-driver
往传送驱动器发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.