E901051 “ Nozzl e is set on %s.|Remove the nozzle.|Nozzle moves to jig ins tall ing position by selecting 'OK' .” “ %s 上有吸嘴。 | 请取下吸嘴。 | 选择 [ 确定 ] ,吸嘴向装配模具位置移动。 ” E901052 “ Nozzl e is not set on %s.|Set nozzle i…

100%1 / 464
E901023 Input value exceeds predetermined data range.”
输入值超过范围。
E901024 There is a parameter which exceeds the range of the input. |Please confirm the parameter.
存在超过范围的参数。|请确认一下参数。
E901025 It is not possible to communicate with the MCM/MCMR.”
不能与MCM/MCMR通讯。
E901026 The error occurred by the communication with the MCM/MCMR.|Expect(0x%05X)
Result(0x%05X)
MCM/MCMR通讯发生错误。|预期值(0x%05X) 结果(0x%05X)
E901027 It is not possible to communicate with the MCM/MCMR.|Received data:0x%05X
不能与MCM/MCMR通讯。|接受的数据:0x%05X
E901028 MCU does not get ready. Status:0x%02X
MCU不能进入准备状态。状态:0x%02X
E901029 Failed in initialization. Status:0x%02X
CPU不能处于停止状态。状态:0x%02X
E901030 The error occurred by writing the flash.|Status:0x%08X
写入闪存发生错误。|状态:0x%08X
E901031 Return to home has not yet been completed.”
没有运行返回原点。
E901032 Servo is in the free state.”
伺服处于不使用状态。
E901033 The written data is not corresponding to the read data.|Write=0x%02X Read=0x%02X
写入的数据与读取的数据不一致。|Write=0x%02X Read=0x%02X
E901034 Timed out waiting for dsout to change. Expect:0x%02X
Timed out waiting for dsout to change. Expect:0x%02X
W901041 Teached data is invalid.”
示教的数据无效。
E901042 Selected device is not install.|Please reselect other device on HOD.”
没有安装被选设备。|请选择其它设备
E901044 Selected device can not move to this position.|Please reselect other device on HOD.”
被选设备不能移到目的位置。|请选择其它设备。
E901051 Nozzle is set on %s.|Remove the nozzle.|Nozzle moves to jig installing position by selecting 'OK'.”
%s上有吸嘴。|请取下吸嘴。|选择[确定],吸嘴向装配模具位置移动。
E901052 Nozzle is not set on %s.|Set nozzle in position.|Move nozzle to jig installing position by selecting
'OK'.| Select 'CANCEL' to ignore.”
%s没有吸嘴。|请安装吸嘴。|选择[确定]吸嘴向装配模具位置移动。| 选择[取消]继续。
E901053 Component of jig has not been picked up.|Check that jig is placed on %s.”
不能吸着模具组件。|请检查模具是否%s上。
E901061 Center-to-center distance of marks cannot be measured.”
不能测量标记中心间距。
E901062 Could not learn the height.|Please check the vacuum value.”
不能取得高度。|请确认一下真空压。
E901063 Rotation center of nozzle is not input.|Setting laser offset
不存在吸嘴旋转中心。|请设定激光偏差。
E901064 1'st mark of CAL block cannot be detected.”
不能查出校准块第一标记。
E901071 Sensor has not been set to OFF state.”
没有关闭传感器。
E901081 Data has not been obtained.”
不能取得数据。
E901101 Error has occurred when detecting height of measuring plane of laser.|Code: %ld
激光测量高度时发生错误。|代码: %ld
E901102 Error has occurred when setting laser parameters.|Code: %ld
设置激光参数时发生错误。|代码: %ld
E901103 Error has occurred during laser measurement(ONCE).|Code: %ld
激光测量(ONCE)时发生错误。|代码: %ld
E901104 Error has occurred during laser measurement(SWEEP).|Code: %ld
激光测量(SWEEP)时发生错误。|代码: %ld
E901105 Error has occurred during the nozzle(component) presence check.|Code: %ld
检测吸嘴(组件)存在性时发生错误。|代码: %ld
E901201 Error has occurred during acknowledgment of CAL piece D by VCS.|Code: %ld|(Return piece D to
CAL block by selecting 'OK'.)
VCS识别校准块D时发生错误。|代码: %ld|(选择[确定],把校准D归还到校准块上)
E901202 Error has occurred during acknowledgment of mark.|Code: %ld
识别标记时发生错误。|代码: %ld
E901203 Error has occurred when measuring center-to-center distance of marks.|Code: %ld
测量标记中心间距时发生错误。|代码: %ld
E901204 Error has occurred during scaling setting.|Code: %ld
设置缩放比例时发生错误。|代码: %ld
E901301 Error has occurred on axis.|Code: %ld
轴发生错误。|代码: %ld
E901302 Error has occurred on axis of XY.|Code:%ld
XY轴发生错误。|代码:%ld
E901303 Error has occurred on axis of Z. (%s)|Code: %ld
Z轴发生错误。(%s)|代码: %ld
E901304 Error has occurred on axis of Theta. (%s)|Code: %ld
θ轴发生错误。(%s)|代码: %ld
E901305 The initialization error of transportation occurred. | Return to home is interrupted. Error code:%ld
搬运的初始化发生错误。|停止返回原点。错误代码:%ld
E901306 The PWB was detected in the transportation road.”
传送轨道上有基板。
W901401 1.Vacuum generating power of ejector is beyond regular level.|Ejectors need to be changed.|2.Air is
leaking from the air pipe path |Air paths need to be inspected.”
1.真空发生器的真空吸引力为规格之外。|需要更换排出器。|2.发生空气管道漏气|需要
检查空气管道。
W901402 1.Vacuum generating power of ejector is low.|Ejectors need to be changed.|2.Air is leaking from
the air pipe path |Air paths need to be inspected.”
1.真空发生器的真空吸引力偏低。|需要更换排出器。|2.发生空气管道漏气。|需要检查空
气管道。
W901403 Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。
W901404 Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”