JUKI贴片机错误代码.pdf - 第414页

" 不能移动贴装头。 -- %s" [Cause] A holder is placed on an pic k position where the head cannot re ach. [Deal] Reposition the holder to where the head can reach. E2953 Head can not move to %s - %d. [Cause] A feeder is …

100%1 / 464
[Cause]
A simultaneous absorbing feeder pair can not be created.
[Deal]
Consult the manufacturer.
E2944 Memory is not enough at making priority of feeder.
"在保护优先区域的进料器顺序处理过程中出现错误。"
[Cause]
Indicates insufficient free memory space.
[Deal]
Exit from other applications, and retry the process.
E2945 Memory is not enough at making for pairing of placement data.
"在保护贴片区域的处理过程中出现错误。"
[Cause]
Indicates insufficient free memory space.
[Deal]
Exit from other applications, and retry the process.
E2946 ATC Nozzle No.Set %d not set.
"请设置 No. %d 吸嘴。"
[Cause]
An essential nozzle is not allocated to ATC during the MSL setup.
[Deal]
Start the MSL setup to set the placement nozzle.
E2947 Head can't move this position. %s - %d
"不能移动贴装头。%s -- %d"
[Cause]
A feeder is placed on an pick position where the head cannot reach.
[Deal]
Reposition the feeder to where the head can reach.
E2948 Head can't move this position. Stick feeder %s - %d lane %d
"不能移动贴装头。 %s -- %d 信道 -- %d"
[Cause]
A stick is placed on an pick position where the head cannot reach.
[Deal]
Reposition the stick to where the head can reach.
E2949 Head can't move this position. Holder %s
"不能移动贴装头。-- %s"
[Cause]
A holder is placed on an pick position where the head cannot reach.
[Deal]
Reposition the holder to where the head can reach.
E2953 Head can not move to %s - %d.
[Cause]
A feeder is placed on an pick position where the head cannot reach.
[Deal]
Reposition the feeder to where the head can reach.
E2954 %s - %d not used.
[Cause]
A stick is placed on an pick position where the head cannot reach.
[Deal]
Reposition the stick to where the head can reach.
E2955 MTC floor %d not used.
[Cause]
A holder is placed on an pick position where the head cannot reach.
[Deal]
Reposition the holder to where the head can reach.
E3001 Program edit has already been started up.
"已经激活编辑程序。"
E3002 A program error has occurred.
"发现一个程序错误。"
E3003 A file I/O error has occurred.
"发现一个文件 I/O 错误。"
[Cause]
Failed in loading or saving a file.
[Deal]
Restart the process.
E3004 The file name is incorrect.
"文件名不正确。"
[Cause]
Appears if a file with an invalid extension or a file unavailable for loading is specified.
[Deal]
Load a valid file.
E3005 Cannot be deleted.
"不能被删除。"
[Cause]
Appears if deleting a component with which linkage is established is tried.
[Deal]
Make sure that no linkage is established with the data to delete, and restart the process.
E3006 Circuit protrudes from circuit PWB.
"电路从电路基板上突出了."
[Cause]
Appears if an entered value deviates from the permissible range of the PWB.
[Deal]
Make sure that the value is specified within the permissible range of the PWB, and restart the
process.
E3007 BOC mark limits are exceeded.
"BOC 标记限制过度。"
[Cause]
Appears if the specified PWB data deviates from the permissible entry range indicated by the BOC
marks.
[Deal]
Make sure that the value is specified within the permissible range indicated by the BOC marks, and
restart the process.
E3008 Bad mark limits are exceeded.
"错误标记限制过度。"
[Cause]
Appears if an entered value deviates from the permissible range indicated by the bad marks.
[Deal]
Make sure that the value is specified within the permissible range indicated by the bad marks, and
restart the process.
E3009 Circuit layout data have not been input, so input is not possible.
"电路设置数据不能输入,所以不能输入。"
[Cause]
Appears if mark data is tried to be entered with "No Matrix" selected for the PWB data, and no data
entered for the circuit arrangement.
[Deal]
Provide the circuit arrangement in the PWB data with data, and reenter the mark data.