JUKI贴片机错误代码.pdf - 第202页

[Cause] The specified ATC Y coordinate i s abnormal. Or the specified co ordinate exceeds the permissive range of the nozzle exchange. The data in the mach ine is broken or the version of the software that is installed o…

100%1 / 464
be performed by selecting [Machine Setup] from the menu bar, and then [Setting Group(G)] [ATC
Nozzle Allocation(A)].
E610031 Parameter for the cylinder is not correct
圆筒的参数不正确。
[Cause]
The specifying of ATC position is abnormal. The data in the machine is broken or the version of the
software that is installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610032 The head is not set to use
Head 处于不使用状态。
[Cause]
The specified head is not enabled to use. The head is set to not use in the Machine Setup.
[Treatment]
Please set the concerned head to use in the Machine Setup or try another head. You can set the head
to use in the Machine Setup with the following procedures. Select [Machine Setup] from the menu
bar, and then select [Setting Group(G)][Use Unit(D)]. Open a dialog with a tub 'Use Unit1', and check
in the checkbox of a concerned head.
E610033 ATC X coordinate is abnormal
X 坐标参数不正确。
[Cause]
The specified ATC X coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610034 ATC Y coordinate is abnormal
Y 坐标参数不正确。
[Cause]
The specified ATC Y coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610035 ATC Y coordinate range error occurred
Y 坐标的误差超过允许范围。
[Cause]
The specified ATC Y coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
If the treatments above do not work, there is a possibility that board(s) in the machine is broken. You
need to replace it(them) with new ones.
E610036 There is no nozzle in the cylinder
圆筒上没有吸嘴。
[Cause]
No nozzle could not be found in the Nozzle presence check by laser. There is a possibility that a
nozzle was taken away from ATC manually or a nozzle installation failed.
[Treatment]
1. If the nozzle was taken away from ATC manually.
Set the nozzle on ATC. If you are not sure which nozzle to set back on ATC, please set a nozzle on
ATC for a time being and perform ATC nozzle allocation. The ATC nozzle allocation can be
performed by selecting [Machine Setup] from the menu bar and then [Setting Group(G)] [ATC
Nozzle Allocation(A)].
2. There was a nozzle on ATC but its installation was not correct.
The following causes are possibly. Please find a cause.
‧There is oily stuff such as grease between the brim of the nozzle that touches ATC and the
installation side of ATC. If there is any oily stuff, please remove it.
‧There is an abnormal nozzle. Please examine if there is any obstructions on the installation part on
the head, or if it is damaged or deformed
‧The nozzle outer shaft (the installation part of a head) is not set correctly. Especially when the error
occurs after changing or cleaning a filter attached to the nozzle outer shaft, please examine if the
outer shaft is installed correctly.
‧Something is wrong with the movement of the ATC slide plate. In this case, the following cases
can be possible.
A) The speed controller of the slide plate driving cylinder is wrung to its minimum limit. Please
loosen the speed controller of the slide plate driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong. There is a possibility that the
sensor gets ON before the slide plate fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being opened/closed. Please examine if
there is anything caught in near the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct. Please examine if the air pipe is
properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the connector part of the slide
plate plays too much. Please examine if the nut is tightened up enough.
The ATC coordinates or the nozzle change height is not correct. If you change the coordinates or the
height, please select [Setup(S)] [MS parameter] and follow the Maintenance manual. For MS
parameter, it is limited that who can change the parameter by the user level setting.
E610037 The nozzle is too long (over 0.5mm). Please check the nozzle installation status
吸嘴过长。(超过 0.5mm)|请检查吸嘴安装状态。
[Cause]
When checking installation status after a nozzle is installed, the nozzle was detected at a position
where the nozzle is not supposed to be detected if it is installed properly. Possible causes are that
nozzles were changed manually, that the nozzle is not installed correctly, or that the window of the
laser measurement unit is dirty.
[Treatment]
1. If a nozzle of the right nozzle number is properly installed.
‧Although the nozzle has the right nozzle number, there is a possibility that a different nozzle was
installed manually. Please perform the ATC nozzle allocation and get the right nozzle length again.
The ATC nozzle allocation can be performed by selecting [Machine Setup] from the menu bar and
then [Setting Group(G)] [ATC Nozzle Allocation(A)].
‧There is a possibility that the measurement height of the laser sensor changed due to the filter
change or cleaning of the nozzle outer shaft (the installation part of a head). If the error occurs after
changing or cleaning a filter attached to the nozzle outer shaft, please examine if the filter is installed
correctly.