JUKI贴片机错误代码.pdf - 第398页

set the VCS to “ Use ” in the Use unit setting in Machine Setup. E906043 “ %s is disable. Selected unit can not measure ” “ %s 是无效设备。 | 被选单元不能测量。 ” [Cause] The selected head is set to “ not use ” in the Use unit settin g…

100%1 / 464
[Cause]
An assemblage position offset of a measured head exceeded the limit value. The limit is: -9.9999
through 9.9999
[Treatment]
System error
Please check the MS parameter.
E906021 Return to home has not yet been completed
尚未结束返回原点。
[Cause]
The axis has not yet been returned to home.
[Treatment]
Please perform the Return to home with ORIGIN switch.
E906022 Servo is in the free state
伺服处于未使用状态。
[Cause]
The axis could not move since the servo is not locked.
[Treatment]
Please lock the servo with S-FREE switch.
E906031 Selected device is not install. Please reselect other device on HOD
没有安装被选设备。|请重新选择其它设备。
[Cause]
You could not go into the teaching mode since the device selected by HOD has not been installed.
[Treatment]
Please reselect the device which is currently installed.
E906041 There is no installed head
不存在可用Head
[Cause]
You could not specify a head since there is no head available.
[Treatment]
Please set to use in the Use unit setting in Machine Setup.
E906042 There is no installed VCS
不存在可用VCS
[Cause]
You could not specify VCS since no VCS has been installed or there is no VCS available.
[Treatment]
Your request is not available on the machine that do not have VCS. If your machine has VCS, please
set the VCS to Use in the Use unit setting in Machine Setup.
E906043 %s is disable. Selected unit can not measure
%s是无效设备。|被选单元不能测量。
[Cause]
The selected head is set to not use in the Use unit setting in Machine Setup.
[Treatment]
Please set the head to use in the Use unit setting in Machine Setup.
E906051 No nozzle 501 or 502 are present in ATC. Add either nozzle using ATC setup
500, 501号及502号吸嘴没有安装在ATC|请利用机器设置的ATC吸嘴分配,设置吸嘴。
[Cause]
501 nozzle and 502 nozzle have not been allocated to ATC. Please allocated a nozzle using the ATC
nozzle allocation in Machine Setup.
[Treatment]
Please assign 501 nozzle or 502 nozzle to ATC in the ATC nozzle allocation in Machine Setup.
E906052 No nozzle 508 or 507 are present in ATC. Add either nozzle using ATC setup
508号及507号吸嘴没有安装在ATC|请利用机器设置的ATC吸嘴分配,设置吸嘴。
[Cause]
508 nozzle and 507 nozzle have not been allocated to ATC. Please allocated a nozzle using the ATC
nozzle allocation in Machine Setup.
[Treatment]
Please assign 507 nozzle or 508 nozzle to ATC in the ATC nozzle allocation in Machine Setup.
E906061 Mark on calibration jig for laser alignment has not been acknowledged. Check the position of jig
不能识别激光校准用校准模具的标记。|请确认一下模具位置。
[Cause]
The mark on the Calibration jig for laser alignment could not be recognized. The position at where
the Calibration jig has been set may be wrong or something is wrong with VCS.
[Treatment]
Please check the jig position and see if the jig is set to be able to see the first mark and second mark
illuminations of the Calibration block from the two holes on the jig. If the jig position is correct, then
something may be wrong with VCS.
E906062 Mark on calibration jig for laser alignment has not been acknowledged
不能识别激光校准用校准模具的标记。
[Cause]
The mark on the Calibration jig for laser alignment could not be recognized. The position at where
the Calibration jig has been installed may be wrong or something is wrong with the vision unit.
[Treatment]
Please check the position of the Calibration jig for laser alignment, which is installed on the
Calibration block. If the position is correct, then something might be wrong with the vision unit.
E906071 Calibration jig for laser alignment has not been picked up. Check that jig is placed on calibration
jig
不能吸取激光校准用校准模具。|请确认一下模具是否置于校准块上面。
[Cause]
Failed to pick up the Calibration jig for laser alignment. An Out-of-component error occurred in the
Laser recognition of the Calibration jig for laser alignment.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration block.
E906072 Calibration jig for laser alignment has not been picked up. Check that jig is placed on jig station
不能吸取激光校准用校准模具。|请确认一下模具是否置于模具站点上面。
[Cause]
Failed to pick up the Calibration jig for laser alignment. An out-of-component error occurred in the
Laser recognition of the Calibration jig for laser alignment.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration station.
E906073 Error between the locations of jig placed and calibration block exceeds limit value. Check the MS
parameter
模具的贴片位置和校准块位置的误差超过界限值。|请检查一下MS参数。
[Cause]
After measuring the assemblage position offset of a head, the Calibration jig for laser alignment was
placed on the center of the Calibration block.. The placement position deviated from the Calibration
block by more than 1.
[Treatment]
System error
Please check the MS parameter.
E906074 Position of calibration jig for laser alignment has irregularities. Check the position of jig
激光校准用校准模具的位置有些异常。|请确认一下模具位置。
[Cause]
The position of the Calibration jig for laser alignment on the Calibration block is irregular.
The center of the recognized mark is more than 0.5mm far from the center of the Calibration block..
[Treatment]
Please place the jig to make the recognized mark 'circular'.
E906075 Calibration jig for VCS has not been picked up. Check that jig is placed on jig station