“ 错误级别低于警告级别。 |ATC : 不能设置 %s 的错误级别。 ” I509210 “ error level is over the Warnin g l evel.|The warning level of %s can not be set .” “ 警告级别高于错误级别。 | 不能设置 %s 的警告级别。 ” I509211 “ The warning level is less th an the error leve…
I508501 “The position where each station is restarted is an installing position not installed at a set station. |The
restart production cannot be done. Please put the data again or clear the restart data.”
“各站台的重新开始位置,在设置站台中,不进行贴片的位置。不能进行重新生产。|请重
新输入数据,或删除重新开始数据。”
I508600 “Because the production program is edited, the thing to do Resume the product cannot be done though
Resume the product file exists. |Resume the product file is deleted.”
“虽然存在继续生产文件,但是正在编辑生产程序,不能进行继续生产。|删除文件。”
I508700 “It is a production program where all the installing points cannot be installed.|Down-loaded the
production programs are produced in the idling mode.”
“这个生产程序不能贴片全部的贴片点,|被下载的生产程序以通过方式进行生产。”
I508710 “Remove the nozzle from %s.”
“ 从 %s 取出吸嘴。 “
Q509000 “%s is re-set.|Would you like to continue the process?”
“重新设置当前显示的设备驱动情报,|是否继续?”
Q509001 “The data with its button currently checked is re-set.|Would you like to continue the process?”
“重新设置当前被选的复选框内容,|是否继续?”
Q509002 “All the Warning levels of Operation Information on each nozzle are re-set.|Would you like to
continue the process?”
“重新设置各吸嘴驱动情况的警告级别,|是否继续?”
I509003 “Button No Check”
“没有选择复选框。”
Q509100 “The selcted area of data is re-set.|Would you like to continue the process?”
“重新设置被选范围内容,|是否继续?”
Q509101 “All the displayed operation Information on each nozzle are re-set.|(Warning level and Error level
are not included).|Would you like to continue the process?”
“重新设置当前显示的各吸嘴驱动情况|(不包括警告级别和错误级别),|是否继续?”
Q509102 “All the displayed operation Information on each head are re-set.|(Warning level and Error level are
not included).|Would you like to continue the process?”
“重新设置当前显示的各吸嘴驱动情况|(不包括警告级别和错误级别),|是否继续?”
I509200 “Warning level is over the error level.|ATC : The warning level of %s can not be set.”
“警告级别高于错误级别。|ATC : 不能设置%s 的警告级别。”
I509201 “The error level is less than the warning level.|ATC : The error level of %s can not be set.”
“错误级别低于警告级别。|ATC : 不能设置%s 的错误级别。”
I509210 “error level is over the Warning level.|The warning level of %s can not be set.”
“警告级别高于错误级别。|不能设置%s 的警告级别。”
I509211 “The warning level is less than the error level.|The error level of %s can not be set.”
“错误级别低于警告级别。|不能设置%s 的错误级别。”
Q509300 “Number of picked components is over the error level.|Number of picked components %d error
level %d|Would you like to set the data?”
“ATC 交换次数超过错误级别。|ATC 交换次数:%d 错误级别:%d|是否设置资料?”
Q509301 “Number of placed components is over the Number of picked components.|Number of placed
components %d Number of picked components %d|Would you like to set the data?”
“总贴片数超过总吸取数。|总贴片数:%d 总吸取数:%d|是否设置资料?”
Q509302 “Number of placed components is over the Number of picked components.|Number of placed
components %d Number of picked components %d|Would you like to set the data?”
“ 交换吸嘴次数超过总吸取数。|交换吸嘴次数:%d 总吸取数:%d|是否设置资料?”
E510001 “The error occurred by the XY axis”
“XY 轴发生错误。”
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510002 “The error occurred by the Z axis”
“Z 轴发生错误。”
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510003 “The error occurred by the Theta axis”
“θ轴发生错误。”
[Cause]
Something was wrong with the Theta axis movement.
[Treatment]
Please perform the Home returning.
E510004 “The error occurred by the axis”
“轴发生错误。”
[Cause]
Something was wrong with axis movement.
[Treatment]
Please perform the Home returning.
E510005 “The command error occurred”
“发生命令错误。”
[Cause]
An UN-recognizable command was issued.
[Treatment]
A wrong version has been installed.
Please install the latest software.
E510006 “Failed in the opening of the master schedule”
“打开主调度程序失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510007 “Failed in create of the mail of the scheduler”
“创建调度程序邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510008 “Failed in the opening of the mail of the application-manager”
“打开程序管理邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510009 “Failed in the mail transmission to the application-manager”
“往程序管理发送邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.