JUKI贴片机错误代码.pdf - 第326页

I650205 “ Conveying Error : Please carry out the PWB on the Exit side sta tion pri or to the one on the Entrance side station ” “ 传送基板错误 : | 请先搬出出口缓冲区的基板。 ” [Cause] On the KE2030 , a request of individual outlet conveyin…

100%1 / 464
1) The cause might be the abnormality of the air plumbing to PWB detector. It could be that the speed
controller was wrung to its limit, that the air plumbing came off, or that the air plumbing is wrong.
Please examine the air plumbing and see if it is connected properly.
2) The PWB detector itself may be broken. Please stop the air supply on the machine and see if the
cylinder shaft works properly or not manually. If the shaft does not work smoothly, you need to
replace it with a new one.
3) The driving solenoid valve may be broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector is broken, that wiring got cut off, or that the solenoid valve
itself is broken. Please examine the wiring and connector part. If anything wrong with them, you need
to replace them with new ones.
  4) If none of the treatments above works, PCB is broken or the wiring between the PCBs is bad.
E650100 Conveying error : An asynchronous, abnormal event occurred while PWB conveying. The process
is forcibly terminated
基板传送错误: |传送基板时,发生异步现象。
[Cause]
The conveying process got forcibly terminated since a critical asynchronous event(Emergency STOP,
etc.) occurred during the PWB conveying.
[Treatment]
Please remove the PWB(s) on the conveyor and perform Home returning.
W650203 PWB Conveying Error: There is no PWB objective to be conveyed
传送基板错误 :|没有发现传送对象基板。
[Cause]
A request of PWB conveying was issued while there was no PWB on the conveyor center station.
This error occurs only at the PWB conveying process(letting PWB come out of the conveyor) that
does not affect on a production.
[Treatment]
Please see if there is any PWB on the conveyor, then execute a process of letting PWB come out of
the conveyor.
W650204 PWB Clamp Error : There is no PWB objective to be unlocked
固定基板错误 :|解除固定时,没有发现对象基板。
[Cause]
A request of unlocking a PWB was issued while there was no PWB clamped on the conveyor center
station. This error occurs only at the PWB conveying process(unlocking PWB) that does not affect on
a production.
[Treatment]
Please see if there is any PWB locked(clamped), then execute a process of unlocking the PWB.
I650205 Conveying Error : Please carry out the PWB on the Exit side station prior to the one on the Entrance
side station
传送基板错误 :|请先搬出出口缓冲区的基板。
[Cause]
On the KE2030, a request of individual outlet conveying for the Entrance station was issued while
there was a PWB on the conveyor center Entrance/Exit station. This error occurs only at the PWB
conveying process(outlet conveying) that does not affect on a production.
[Treatment]
Please have a PWB on the center Exit station go first or have PWBs on both station go together.
E650208 PWB Conveying Error :| Central motor Stop Check error.”
传送基板错误 :|检查中心马达停止错误。
[原因]
中心马达停止控制异常。作为原因,能考虑轴控制器基板的异常状态
[解决]
关闭设备,关掉电源之后,请重新启动。
当以上的处理没有解决问题时,能考虑为轴控制基板的故障。
请与代理店或本公司技朮服务部取得联系。
W650209 PWB Conveying Error : A PWB has been detected on the conveying route. Please remove it
传送基板错误 :|传送轨道上发现基板。|请取下基板。
[Cause]
While conveying PWBs, an unexpected PWB was detected at the several buffers on the conveyor.
[Treatment]
Please remove the PWB from the conveyor.
W650211 PWB Conveying Error : A PWB has been detected on the center station. Please remove it
传送基板错误 :|C.OUT传感器发现基板。|请移走出口缓冲区的基板。
[Cause]
While conveying PWBs, an unexpected PWB was detected at the center station on the conveyor.
[Treatment]
Please remove the PWB from the center station.
W650212 PWB Conveying Error: A PWB has been detected on the center station on the Entrance side.
Please remove it
传送基板错误 :|在入口侧中心缓冲区,发现基板。|请取下基板。
[Cause]
While conveying PWBs on the KE2030, an unexpected PWB was detected at the center Entrance
station on the conveyor.
[Treatment]
Please remove the PWB from the center Entrance station.
W650213 PWB Conveying Error : A PWB has been detected on the center station on the Exit side. Please
remove it
传送基板错误 :|在出口侧中心缓冲区,发现基板。|请取下基板。
[Cause]
While conveying PWBs on the KE2030, an unexpected PWB was detected at the center Exit station
on the conveyor.
[Treatment]
Please remove the PWB from the center Exit station.
W650214 PWB Conveying Error : A PWB has been detected on the OUT buffer. Please remove it
传送基板错误 :|在出口缓冲区,发现基板。|请取下基板。
[Cause]
While conveying PWBs, an unexpected PWB was detected at the OUT buffer on the conveyor.
[Treatment]
Please remove the PWB from the OUT buffer.
E650218 PWB Conveying Error :| Received resume originating command | in other condition of resume
temorary stop.”
传送基板错误 :|不是恢复暂停状态,|却被接受恢复返回原点命令。
W650219 PWB Conveying Error : In operation of PWB conveying
传送基板错误 :|正在传送基板。
[Cause]
A new request of PWB conveying was issued before a previous request of PWB conveying got
complete (Program error).
[Treatment]
Please see the error message, and remove all the PWBs on the conveyor. Then try the request again.
E650221 PWB Conveying Error : Illegal input buffer motor movement. The process is forcibly terminated.
Please remove on the conveying route
传送基板错误 :|待传感器OFF超时。
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN sensor when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.