JUKI贴片机错误代码.pdf - 第460页

[Cause] The %dth part data is incomplete. [Deal] Complet e the part data. E6813 Adhesi on data at %d position is not completed. " 在% d 位置的贴装数据 不完全。 " [Cause] The %dth adhesion data is incomplete. [Deal] Complet…

100%1 / 464
-The data specified overlaps the range for installing the placement part. Placement part overlaps the
absorption data.-The absorbing positions specified part overlap one another. The absorbing positions
specified part overlap one another.
E6800 Error occurred in the dispenser division memory.
"分配划分内存出现错误。"
[Cause]
Reserving the memory for the application data allocation table was failed.
[Deal]
Exit from other applications and retry the process.
E6801 Placement data overflowed during dispenser division. (station No.%d)
"在分配区域时贴片数据溢出。(位置号%d)"
[Cause]
The maximum limit for the applicator mounting data was exceeded.
[Deal]
Decrease the application mounting or application-only data in the mounting data.
E6802 Component data overflowed during dispenser division. (station No.%d)
"在分配区域时组件数据溢出。(位置号%d)"
[Cause]
The maximum limit for the applicator part data was exceeded.
[Deal]
Decrease the application mounting or application-only data in the mounting data.
E6803 Adhesion data overflowed during dispenser division. (station No.%d)
"在分配区域时粘性数据溢出。 (位置号%d)"
[Cause]
The maximum limit for the applicator adhesion data was exceeded.
[Deal]
Decrease the adhesion data.
E6811 Placement data at %d position is not completed.
"%d 位置贴片的数据不完全。"
[Cause]
The %dth mounting data is incomplete.
[Deal]
Complete the mounting data.
E6812 Component data at %d position is not completed.
"%d 位置的组件数据不完全。"
[Cause]
The %dth part data is incomplete.
[Deal]
Complete the part data.
E6813 Adhesion data at %d position is not completed.
"在%d 位置的贴装数据不完全。"
[Cause]
The %dth adhesion data is incomplete.
[Deal]
Complete the adhesion data.
E6814 Station data at %d position is not completed.
"%d 位置放置数据不完全。"
[Cause]
The %dth station data is incomplete.
[Deal]
Complete the station data.
E6821 A system error occurred in dispenser division.
"分配划分出现一个系统错误."
[Cause]
The numbers of the needles and stations are not corresponding with each other.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6822 Needle setting of data at %d position is abnormal.
"%d 位置针设置数据不正常."
[Cause]
The needle type for the specified station is different from the needle type for the adhesion data.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6900 Insufficient memory in optimization.
"优化时内存不足."
[Cause]
Indicates insufficient free space in the memory.
[Deal]
Exit from other applications and retry the process.
E6901 Circuit number is out of range.
"电路数量超出范围."
[Cause]
The maximum number of circuits available for this line was exceeded.
[Deal]
Decrease the data (number of PWB data circuits) to the limit or less.
E6902 Needle number Error.
"针数量错误."
[Cause]
The needle type for the specified station is different from that for the adhesion data.
[Deal]
Start the MSL setup to check the needle type and set the needle type to use for the program data.
E6903 Head number undefined Error.
"贴装头数量未定义."
[Cause]
A failure was found in the data.
[Deal]
Correct the data (adhesion data needle) specification.
E6904 Head number Error.
"贴装头的数量错误."
[Cause]
The head to use is disabled.
[Deal]
Start the MST setup to enable the needle.
E6905 Placement position is out of range.
"贴片位置超过范围."
[Cause]
Excessive mounting data were specified.
[Deal]
Decrease the mounting data to the limit or less.
E6906 Internal Error.
"内部错误."
[Cause]
EPU770 (Hlc Div Dispensor Optimize) error return values, -2, -3, -4
[Deal]
Consult the manufacturer.