JUKI贴片机错误代码.pdf - 第427页

[Deal] Set the IC head or LAIC head to "Used" in the "Unit conditions " field of the "Station profile" window invoked from the MSL Setup program. E3809 No st ation VCS or opti on VCS useful …

100%1 / 464
Enable the bad mark reader for the unit status of the station profile during the MSL setup.
E3804 No pick and place machine.
"没有选择和贴片机器!"
[Cause]
Appears if no mounter is set for line specified during the MSL setup, despite the "Only Mounting" or
"Mounting-Application" is set for the "Application/Mounting" in the mounting data.
[Deal]
Set a mounter on the line during the MSL setup or change the item. "Application/Mounting" to
"Only Application" in the mounting data.
E3805 No Adhesive dispenser.
"没有贴装分配!"
[Cause]
Appears if no dispenser is set on the line specified during the MSL setup, despite "Only Application"
or "Mounting-Application" is set for the "Application/Mounting" in the mounting data.
[Deal]
Set a dispenser on the line during the MSL setup or change the item. "Application/Mounting" to
"Only Mounting" in the mounting data.
E3806 Head can't move to placement position.
"贴片头不能移动到放置位置."
[Cause]
The component placement position is not within the area where a had can move.
[Deal]
Change the placement position within the area where a head can move.
E3807 Station which do not use IC or LAIC head in the line.
"在线上不能使用 IC LAIC 头的位置."
[Cause]
Appears if 720 or 740 is specified for the line, but the item, IC or LAIC head, is disabled for the unit
status in the station profile of the MSL setup, or if a vision part is used without 720 or 740.
[Deal]
Enable the item, IC or LAIC head, in the unit status of the station profile during the MSL setup.
E3808 IC head or LAIC head cannot be used on selected station.
"IC 头或 LAIC 头在选择位置不能使."
[Cause]
Although a 720, 740 or 760 is specified for the line, "Not used" is specified for the IC head or LAIC
head in the "Unit conditions" field of the "Station profile" window which is invoked from the MSL
Setup program.
[Deal]
Set the IC head or LAIC head to "Used" in the "Unit conditions" field of the "Station profile"
window invoked from the MSL Setup program.
E3809 No station VCS or option VCS useful exists.
"在线上没有位置能使用随意的 VCS."
[Cause]
Appears if the item, standard VCS or option VCS, is disabled in the unit status of the station profile
during the MSL setup.
[Deal]
Enable the item, standard VCS or option VCS, in the unit status of the station profile during the
MSL setup.
E3810 option VCS cannot be used on selected station.
"指定的位置没有设置成使用可选择 VCS."
[Cause]
Appears if the item option VCS is disabled in the unit status for the station profile during the MSL
setup, with 720, 740,760,2020,2040 specified for the station.
[Deal]
Enable the item option VCS in the unit status of the station profile for the specified station.
E3811 No station optioned with chip stand detect is in the line.
"在线上没有位置能有芯片站立探测."
[Cause]
Appears if 710 or 720 is set for the line but the item, chip-standup detector, is disabled in the unit
status of the station profile during the MSL setup.
[Deal]
Enable the item, chip-standup detector, in the unit status of the station profile during the MSL setup.
E3812 Chip stand detect option cannot be used on selected station.
"芯片站立探测项不能在选择位置使."
[Cause]
Although a 710 or 720 is specified for the line, "Not used" is specified for the chip stand detect option
unit in the "Unit conditions" field of the "Station profile" window which is invoked from the MSL
Setup program.
[Deal]
Set the chip stand detect option to "Used" in the "Unit conditions" field of the "Station profile"
window which is invoked from the MSL Setup program.
E3813 Component data per a station exceeds maximum.
"每个位置的组件数据超出最大值."
[Cause]
The maximum number of part data available for one station varies depending on station types: 80 for
710, 81 for 720,200 for 770, and 120 for 730, 740, 750,760,2000 series,240 for 775.
[Deal]
Decrease the number of part data to the acceptable level.
E3814 An unusable head is assigned in selected station.
"在选择位置分配不可使用头."
[Cause]
The necessary head is not set for the specified station in the "Unit conditions" field of the "Station
profile" window which is invoked from the MSL Setup program.
[Deal]
Set the necessary head in the "Unit conditions" field of the "Station profile" window which is
invoked from the MSL Setup program.
E3815 A necessary needle is not in selected station.
"必须的针没有在选择位置."
[Cause]
Appears if the needle required for the specified station is not set in the unit status of the station profile
during the MSL setup.
[Deal]
Specify the necessary needle in the unit status of the specified station for the specified station.
E3816 Adhesive data per a station exceeds maximum.
"每个位置的贴装数据超过最大值."
[Cause]
Indicates that more than 200 adhesion data were set but there is only one 770 on the line or, 240 or
more adhesive data pieces were set although there is only one 775 installed on the line.
[Deal]
Decrease the number of the adhesion data to the limit or less.
E3817 No vision centering station is in the line.
"在线上没有图像中心位置."
E3818 Station which can handle tray package is not in the line.
"能处理盘包装的位置不在线上."
[Cause]
Appears if no station capable of using trays is set for the line but trays are used.
[Deal]