00196044-05 - sg x und x4i fse_en.pdf - 第159页

Communication and Control Reading the Board IDs out of the EEPROM Board IDs S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Communication and Control 159 4.6.2 Reading the Board IDs out of the EEPROM Th…

100%1 / 632
Communication and Control
Board IDs What are Board IDs?
Student Guide (FSE) SIPLACE X Series and X4I
Communication and Control Edition 01/2009 EN
158
4-57: Overview of board IDs, checked by the TQM module (SIPLACE X series and X4I with SW 70x)
In X series machines with TQM, the PCB ID is read out of the BIOS.
In X series machines with HCU, the PCB ID is read out of the application.
4-58: Board IDs for Vision boards (SIPLACE X)
NOTE:
The board ID for the Vision board (gantries 1 - 4), the illumination board for the stationary
cameras (sector 2/4) and the holding circuit vacuum sensor board for C&P20 are currently not
evaluated.
Communication and Control
Reading the Board IDs out of the EEPROM Board IDs
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Communication and Control
159
4.6.2 Reading the Board IDs out of the EEPROM
The board ID can be checked with the help of the
Caccia
tool.
You can use CAN Bus commands to read the board type IDs or open the corresponding menu to read
the memory of the EEPROM. When one or more ID‘s are missing so you can write the correct ID on the
board.
At the moment it is necessary to use the correct ID‘s on the board which are installed on the gantry (Head
interface, - adapter, Intermediate distributor and main board). The other board type ID‘s are not used at
the moment.
4.6.2.1 Reading Out the Board Type ID via the Gripper Menu
X Switch off the machine.
X Connect the service laptop to the machine CAN bus at PA1 and/or PA2.
Make sure that the cable is connected at channel 1 for PA1 and at channel 2 for PA2 of the Kvaser
card.
X Switch on the machine
X Start the
Caccia
software and check the machine configuration in
Caccia
.
X Doubleclick on the
Open Subsystem Control Center button.
Select
Get Versions
. All available subsystems will be shown with their firmware versions and their CAN
IDs.
X Select the head processor for the relevant gantry e.g. gantry 1.
X Open the
GSM
folder.
ATTENTION:
Direct CAN bus commands should only be used by specially trained and qualified service
technicians.
NOTE:
When you want to be read out the board type ID‘s via the menu gripper, the BIOS and
application-software have to downloaded on the TQM module. Reading out is currently only
possible via the
Gripper
menu. to write the ID‘s on the EEPROM you need CAN Bus
commands.
Change Properties Change Machine
Configuration
Open Subsystem Control
Center
Communication and Control
Board IDs Reading the Board IDs out of the EEPROM
Student Guide (FSE) SIPLACE X Series and X4I
Communication and Control Edition 01/2009 EN
160
4-59: Subsystem control center
X Double-click on
Gripper
and the following dialog box will open:
4-60: Dialog head processor gripper
X Select the board to be checked
Off
then select the button
Get EEPROM.