00196044-05 - sg x und x4i fse_en.pdf - 第625页

Measuring Equipment and T ools Scope of Delivery Adjustment Aid for C&P DLM [00327005-01] S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Measuring Equipment and T ools 629 15.10 Adjustment Aid for …

100%1 / 632
Measuring Equipment and Tools
Location Tester Scope of Delivery
Student Guide (FSE) SIPLACE X Series and X4I
Measuring Equipment and Tools Edition 01/2009 EN
628
15.8 Location Tester
15.9 Z-End Stopper Star Gauge for C&P6/12 [03019865-01]
Application:
The location tester is used to check the feeder
connections at the communication unit of the
changeover table.
Application:
The gauge is used to set the end stop position
of the C&P head Z axis.
Measuring Equipment and Tools
Scope of Delivery Adjustment Aid for C&P DLM [00327005-01]
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Measuring Equipment and Tools
629
15.10 Adjustment Aid for C&P DLM [00327005-01]
Complete set: Art. No. 00327005-01
1. Gauge for star [00326164-01]
2. Test probe 1.4 mm [00326160-01]
3. Test probe 1.5 mm [00326161-01]
4. Test probe 1.6 mm [00326162-01]
5. Test probe 1.0 mm [00376656-01]
6. Distance gauge [00325445-01]
Measurement tools Application type
Gauge for star Setting the zero point correction for the star
Test probe 1.4 mm Setting the distance between the DP station incremental encoder and the glass for
the sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance from the Z axis light barrier down to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star
Measuring Equipment and Tools
Calibration Tool [03010565-01] Scope of Delivery
Student Guide (FSE) SIPLACE X Series and X4I
Measuring Equipment and Tools Edition 01/2009 EN
630
15.11 Calibration Tool [03010565-01]
15.12 Calibration Tool [003034148-xx]
Application:
The calibration tool [003010565-xx] is used for
calibration of the C&P6/12, CPP, P&P and
Twin Head (for X-series) placement heads.
Application:
The calibration tool [003034148-xx] is used for
the C&P20A placement head.
It is used in X series machines for calibration
of the component camera SST23.