00196044-05 - sg x und x4i fse_en.pdf - 第195页

Energy and Compressed Air Supply Power Distribution Power supply S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Energy and Compressed Air Supply 195 5-22: power distribution Legend 1 Main distributor v…

100%1 / 632
Energy and Compressed Air Supply
Power supply Power Distribution
Student Guide (FSE) SIPLACE X Series and X4I
Energy and Compressed Air Supply Edition 01/2009 EN
194
5.2.10.3 Control On Signal
If connector K4 of the power supply is enabled, the auxiliary contact K4.5 will close and 24 V (servo
release signal) will be present from the DC/DC converter to the distributor of the main power supply X13,
to the axis unit X21 and to the anti-crash board.
The introduction of the A364 also involved direct software realization of the anti-crash function on the
axis card.
Here it is split in 2 paths:
Path 1: 24 V present as
Servo enable signal
at the X/Y axis servo board, to enable the servo amplifier
(to switch GND to the servo board via optical coupler).
Path 2: 24 V present as
Ctrl_ON
signal at sector 2, connector X4qa and ends as M_Ctrl_On at the CAN
I/O module. The 4 main axis is allowed to move now into any position.
5-21: Control On signal
5.2.11 Power Distribution
The power distribution to the different sectors, gantries and heads is highly structured. 5V and 24 V,
generated by DC/DC converter U20 and U30 in main power supply, will first activate at distributor main
power supply, connector X16. Then at section 2, main distributor, connector X2qa and then at the
terminal block X1qa for general use, at connector X71qa and at last at connector X71ra, section 4.
52 V for camera illumination, generated by U7, is activated at main power supply distributor, X18, and
split into two paths.
Path 1: from X18, at section 2, X3qa, to terminal strip X1qa and then to the DC/DC converter Vision for
converting the 42 V needed for the IC/FC camera illumination. The voltage is also present via connector
X71qa to connector X71ra in sector 4 and to X1ra, ending at the DC/DC distributor Vision (42V are not
used here).
Path 2: (this path is currently not used) from X18 at sector 2, X3ra, to terminal strip X1ra and then to the
DC/DC distributor Vision for converting the 42 V needed for IC/FC camera illumination in this sector.
The voltage supply +/-15 V is generated at the power pack in the axis unit from the 52 V and is then
present at X4qa, at the terminal strip X1qa, for general distribution and use. The voltage is then present
via X74qa to X74ra in sector 4 to the intermediate distributor (not shown in the following diagram).
Energy and Compressed Air Supply
Power Distribution Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
195
5-22: power distribution
Legend
1 Main distributor voltage supply 4 Terminal strip X1qa sector 2
2 Connections – main distributor sector 2 5 Terminal strip X1ra sector 4
3 Subdistributor sector 4
Energy and Compressed Air Supply
Pneumatic System Pneumatic Unit
Student Guide (FSE) SIPLACE X Series and X4I
Energy and Compressed Air Supply Edition 01/2009 EN
196
5.3 Pneumatic System
5.3.1 Pneumatic Unit
The pneumatic unit is mounted on a compact slide-in module, and located on the right side of the middle
section. A lockable door prevents access to the unit, which contains the whole compressed air supply
as required for the machine and its options. The pneumatic unit also contains the conveyor control, which
assumes control of PCB transportation in the machine and to the upstream and downstream stations.
(see Chapter Conveyor)
5-23: Pneumatic Unit
Legend
1. Manometer 2.5 bar for bulkcase or nozzle
changer DLM
2. Manometer for gantries 4.8 bar
3. Manometer for machine components 5 bar
(docking unit, conveyor, cutter, NC C&P20)
4. Manometer for input pressure, min. 5 bar
5. Main shutoff valve
6. New air filter - air filter housing of metal with
bayonet connection and filling level display
5-24: Pneumatic Unit
Legend
1. Pressure sensor
2. Manual regulator for cutters and machine
components
3. Proportional valve
4. Main compressed air connection (5-10 bar)
5. Gantry distributor with shutoff valves for each
gantry
6. 5 bar connections for docking unit or nozzle
changer C&P20
7. Main valve for machine components
8. Manual regulator for 2.5 bar bulkcase
9. 2.5 bar connections for bulkcase or NC C&P6/
12
10. Safety valve for cutters