11.3.8 Lifting Table Functions
Lifting table up function
Requirements for detecting that the lifting table is up:
30-35 pulses from the incremental disc
Check performed by software (see Section (11.3.7 Board Clamping Functions
J
459 ) )
Dynamic response for board clamping of approx. 500 ms
Lifting table down function
Requirements for detecting that the lifting table is down:
30-35 pulses from the incremental disc
Proximity switch on the lifting table cylinder
Dynamic response for board release of approx. 480 ms
11.3.8.1 Adjusting the Speed of the Lifting Table (from SW701)
11-19: Lifting table unit
Legend
1. Actuator
2. Lock nut damper
3. Fastening screws for mounting block
4. Damping unit
5. 3/5 way solenoid valve mounted on lifting table
drive cylinder
6. Fork-type light barriers / incremental disk
11-20: Time needed to move lifting table up with lifting table plate
X Switch the machine on.
X In the
Conveyor --> Conveyor functions and
manual checks
menu, you can move the
lifting table up and down. The time is shown
directly.
X Select
Actuate Clamp
.
Modular Conveyor
Conveyor Settings Lifting Table Functions
Student Guide (FSE) SIPLACE X Series and X4I
Modular Conveyor Edition 01/2009 EN
462
X If the travel times are not inside the tolerance range or if error messages appear during production,
adjust the travel times as follows:
X Adjust the valve on the lifting table cylinder, so that you get the following values:
X If malfunctions occur during the downwards movement or if the board is shaken, reduce the lowering
speed accordingly.
Setting valve anticlockwise: Decrease the lifting table moving time
Setting valve clockwise: Increases the lifting table moving time
11-21: Time needed to move lifting table down with lifting table plate
X The lifting table will be moved up and the travel
time will be displayed (see diagram).
X Press the
Actuate Clamp
button again to
move the lifting table downwards and to view
the travel time for the downwards movement.
Lifting table Move upwards Move downwards
Lifting table (standard)
bumper: 20 mm
520 ms +/- 20 ms 480 ms +/- 20 ms
Lifting table (X4I)
bumper: 35 mm
430 ms +/- 20 ms 400 ms +/- 20 ms
Legend
1. Adjust valve downwards
2. Adjust valve upwards
Modular Conveyor
Checks After Mechanical Work on the Conveyor Conveyor Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Modular Conveyor
463
11.3.8.2 Setting the Lifting Table Unit [00358684-05]
11.3.9 Checks After Mechanical Work on the Conveyor
Check: The distance between the top edge of the conveyor belt and the top stop should be 6 mm.
11-22: Setting the damping unit
The damping unit (1) allows the lifting table to
move gently upwards. When the PCB is clamped,
it also prevents excessive bounce by the PCB.
X Check whether the damping unit is fixed with
the locknut (2) in the mounting block and that
the plunger (3) of the damping unit is just
touching the actuator (4). In this default
setting, the lifting table should move up gently.
X If this is not the case, loosen the locknut at the
mounting block and turn the damping unit
approx. one rotation into the mounting block..
X Move the lifting table upwards, with the help of
the software.
X The lifting table should move gently upwards.
The PCB clamping should not engage audibly
and there should be no PCB clamping error
message.
X Check the speed of the lifting table and correct