00196044-05 - sg x und x4i fse_en.pdf - 第298页
C&P20A Room for Your Sketches and Notes Axis Control of DP Axis S tudent Guide (FSE) SI PL ACE X Series and X4I C&P20A Edition 01/2009 EN 298

C&P20A
Axis Control of DP Axis Room for Your Sketches and Notes
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN C&P20A
297

C&P20A
Room for Your Sketches and Notes Axis Control of DP Axis
Student Guide (FSE) SIPLACE X Series and X4I
C&P20A Edition 01/2009 EN
298

Collect, Pick and Place Head (CPP)
Important Information
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Collect, Pick and Place Head (CPP)
299
8 Collect, Pick and Place Head (CPP)
8.1 Important Information
8.2 Overview
ATTENTION: Head exchange
When replacing the Twin Head with a CPP head with MTC2 in this placement area, you need
to fit a bumper extension, to limit the Y travel range. After switching the machine back on, you
then need to redetermine the machine zero point and the travel ranges.
When you use a Twin Head again, you need to remove the bumper extension.
ATTENTION: Risk of head crash!
When installing a CPP head with a stationary camera, this needs to be fitted in the top position,
otherwise there is a risk of a head crash!
8-1: CPP head overview
CPP head (without component camera)
[03053528-xx]
Legend
1. Intermediate distributor 1 and 2
2. Star motor (integrated in head housing)
3. DP axis (as direct drive)
4. Pressure Control Valve
5. Component camera (standard: SST29)
6. Single Core Solution (SCS) – control DP
drives
7. Hold circuit with venturi nozzles and valve
terminal
8. Z axis with return cylinder
9. Component sensor in the pick and place
position