00196044-05 - sg x und x4i fse_en.pdf - 第397页
Twin Head Axis Control Twin Head D-Axis Axis Control S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN T win Head 397 9.6.5.2 Measurement Setup The axis d ynamic is test ed over differ ent distanc es. SIT…

Twin Head
Axis Control Axis Control Twin Head D-Axis
Student Guide (FSE) SIPLACE X Series and X4I
Twin Head Edition 01/2009 EN
396
9.6.5 Axis Control Twin Head D-Axis
9.6.5.1 Checking the Twin Head D-Axis Dynamics
The D-axis is driven by a 2-phase AC motor, fed
from 60 V DC voltage. Axis control is via 2 control
signals from the VC3 controller (phase shift 90°) I
nom "W" and I nom "U".
Legend
1. Axis controller board A363 with VC3 controller
(VC = Velocity Commutation) or A 364
2. Control signals
3. Servo amplifier
4. LEDs on servo board:
– Power supply ON
– Servo enable, if the enable signal has
been received from the axis board.
– Display R.M.S. current limiter shorter than
2.5 s.
– Error: Overvoltage, overcurrent,
overtemperature or nominal current
overshoot longer than 2.5 sec.
5. 2 phase AC motor.
6. Between the motor and the incremental
encoder there is a fixed mechanical
connection.
7. Incremental encoder: transmits the exact
position of the axis (track signals).
The servo board controls the AC motor directly.
NOTE:
The positioning times between the left and right turns of the sleeve may deviate from one
another considerably. However, the time characteristic of this axis is not critical for Twin head
operation, due to the placement procedure.

Twin Head
Axis Control Twin Head D-Axis Axis Control
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Twin Head
397
9.6.5.2 Measurement Setup
The axis dynamic is tested over different distances.
SITEST
X Select
TWIN Head
==>
Axis functions
==>
Segment
==>
DP axis
==>
Select Axis continuous run
==> edit and accept values:
Target position: 1000 1/100° = 10° = 10000 digits;
Positioning type: absolute.
Waiting period: 200 ms
X Press the START button if required.
Twin head - D-axis with 10 degrees rotation
9-35: Travel curves for D axis with 10 degrees rotation
Legend
NOTE:
The measurement procedure follows the same preparations and procedures as for the Z axis
1 Current nominal value 200 mV/Div Target positioning
time:
approx. 90 ms +/-10,
range 10000 digits
2 Position deviation 500 mV/Div Time basis 50ms/Div
3 End position signal 5 V/Div

Twin Head
Axis Control Axis Control Twin Head D-Axis
Student Guide (FSE) SIPLACE X Series and X4I
Twin Head Edition 01/2009 EN
398
TWIN head - D axis with 90 degrees rotation
9-36: Travel curves for D axis, 90 degrees rotation (to the right)
Legend
1 Current nominal value 200 mV/Div Target positioning
time:
approx. 160 ms +/-20,
range 90000 digits
2 Position deviation 500 mV/Div Time basis 50ms/Div
3 End position signal 5 V/Div