00196044-05 - sg x und x4i fse_en.pdf - 第520页
Head Modularity Head Modularity CPP/C&P to Twin Head Calibration S tudent Guide (FSE) SI PL ACE X Series and X4I Head Modularity Edition 01/2 009 EN 524 13.4 Head Modularity CPP/C&P to T win Head 13-4: Procedure …

Head Modularity
Calibration Head Modularity
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Head Modularity
523
13.3.3.1 Autoconfiguration
X After the zero point correction has been transferred, check the nozzle configuration at the placement
head and in the nozzle changer.
X Perform a complete calibration of the placement head.
X If the head has been precalibrated, brief calibration can be performed with the menu
Fast Head
Exchange
!
After the head exchange or replacing other
hardware components, an automatic configuration
will be performed when machines with software
702 or higher are restarted.
This means that manual configuration settings
should no longer be necessary.
X This menu allows you to check the
configuration and change it if required.
This is where the axis data (Z and star axes) can
be written from the head EPROM to the machine
data. You can also write the Z and star axis data
from the machine data to the head EPROM.
X In the
Zero correction data
(1) select the line
Zero point correction
(2).
X ;Move the value out of the head EPROM and
into the machine data (3).
X Select
Write head & machine data
(4).
X The arrow button (5) takes you back one menu
level.

Head Modularity
Head Modularity CPP/C&P to Twin Head Calibration
Student Guide (FSE) SIPLACE X Series and X4I
Head Modularity Edition 01/2009 EN
524
13.4 Head Modularity CPP/C&P to Twin Head
13-4: Procedure for head exchange CPP/C&P to TwinHead

Head Modularity
Calibration Head Modularity Twin Head to CPP/C&P
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Head Modularity
525
13.5 Head Modularity Twin Head to CPP/C&P
13-5: Procedure for head exchange TwinHead to CPP/C&P