12.5 Teaching Machine Positions
12.5.1 General Procedure
The function Teaching machine positions can be
performed with the user level
Machine service
(1)
or
Siemens service
.
A successful overall machine reference run is a
precondition for this.
X Switch over to the service menu (2).
X Click on
Teaching Machine Positions
(3)
button, to start the wizard.
The machine positions are divided into the
following positions:
Conveyor
Processing area
Table
Gantry
Nozzle changer
X Select the position to be taught (1).
X Click on
Move to position
(2).

Calibration
Teaching Machine Positions General Procedure
Student Guide (FSE) SIPLACE X Series and X4I
Calibration Edition 01/2009 EN
494
Explanation of terms and definitions
The machine positions will be approached.
X By clicking on the fiducial window (1) you will
see a range of other functions (2), such as
those for moving or centering the fiducial
window.
X Click on
Next
(3) to teach the fiducial
(position).
X Select the step size and teach the gantry, so
that the PCB camera is centered above the
fiducial (1).
X Click on the Save (2) button.
The field (3) shows the target values from the
machine data and the taught offset.
Zero Offset Fid_1L
Zero Offset Fid 1 L
Machine zero point Fiducial Placement area 1 L = left gantry (gantry 4)
R = right gantry (gantry 1)
CalibrationPart_5_Location_L
CalibrationPart 5 Location_L
Calibration pocket Small calibration tool for C&P20A Location on the left side, gantry 3 or 4

Calibration
Teaching Machine Positions - Table Teaching Machine Positions
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Calibration
495
12.5.2 Teaching Machine Positions - Table
12.5.2.1 Teaching Machine Positions - Feeder
The table (fiducial) which corresponds to the
gantry chosen (location) can now be taught.
Naming convention
1. DeviceLocation_1_L.XTable: Fiducial 1 (only
used at locations 1 and 3)
2. DeviceLocation_1_L.XTable: Fiducial 2
3. DeviceLocation_1_L.XTable: Fiducial 3 (only
used at locations 2 and 4)
4. DeviceLocation_1_L.XTable: Fiducial 4 (is not
used)
In addition to the tables (fiducials), all pickup
positions for the configured feeders can be
checked and taught.
X For example, select
Slot 02: Position
Correction
(1)
X The pickup position will be approached (2).
X Teach with the
Next
(3).